KyoChul Seo1, SeungHwan Park2, KwangYong Park3. 1. Department of Physical Therapy, Korea Nazarene University, Republic of Korea. 2. Department of Medical Engineering, Eulji University, Republic of Korea. 3. Department of Rehabilitation Technology, Korea Nazarene University, Republic of Korea.
Abstract
[Purpose] This study investigated the effects of proprietary foot orthotics in young adults with flatfoot to determine changes in the ankle joint angle in the coronal plane during the midstance phase. [Subjects and Methods] The subjects were 15 college students diagnosed with flatfoot. Changes in the ankle joint angle in the coronal plane in the midstance phase were measured using the Vicon Motion System before and after use of the orthotic. The data were analyzed using Statistical Package for the Social Sciences Win 16.0. [Results] The subjects showed significant increases in left and right ankle joint angles in the coronal plane during the midstance phase of the gait cycle after use of the orthotics. However, the difference between the left and right ankle joint angles showed no significant change, even though the difference increased after use of the orthotics. [Conclusion] Young adults with flatfoot showed increased ankle joint angles after use of the orthotics. This suggests that orthotic footwear can shape the plantar arch and affect the ankle joint, and that constant use of orthotics would cause a dynamic change in normal walking.
[Purpose] This study investigated the effects of proprietary foot orthotics in young adults with flatfoot to determine changes in the ankle joint angle in the coronal plane during the midstance phase. [Subjects and Methods] The subjects were 15 college students diagnosed with flatfoot. Changes in the ankle joint angle in the coronal plane in the midstance phase were measured using the Vicon Motion System before and after use of the orthotic. The data were analyzed using Statistical Package for the Social Sciences Win 16.0. [Results] The subjects showed significant increases in left and right ankle joint angles in the coronal plane during the midstance phase of the gait cycle after use of the orthotics. However, the difference between the left and right ankle joint angles showed no significant change, even though the difference increased after use of the orthotics. [Conclusion] Young adults with flatfoot showed increased ankle joint angles after use of the orthotics. This suggests that orthotic footwear can shape the plantar arch and affect the ankle joint, and that constant use of orthotics would cause a dynamic change in normal walking.
Walking is essential for daily life, and feet play an important role in supporting the body
and maintaining balance during walking1).
Flatfooted walking induces excessive foot pronation, which transfers the weight load to the
tibia, causing pain in the tibia and knee. This can result in damage to the lower limb2). Flatfoot is characterized by a medial
longitudinal arch that is lowered in a chronic or abnormal way, resulting in excessive
stretching of the plantar fascia, spring ligament, and tibialis posterior tendon3). The ability to receive and disperse weight
decreases with abnormality of the sole structure, and excessive compensation by the outer
muscles causes foot imbalance4).Previous research on functional foot orthotics (FFOs) has produced many results for the
treatment of congenital and acquired flatfoot. Pratt5) examined the prevention or correction of foot deformity, formation
of sufficient supporting ground, promotion of standing or walking exercise, and improvement
of walking efficiency. Feet play an important role in the lower kinetic chain; they
distribute the weight load generated during exercise and disperse it in the stance period
during walking. Song6) reported that
orthotics decrease both pronation and internal rotation of the tibia. And proper insoles and
orthotics could reduce muscle activity, provide comfort, and increase exercise ability7, 8). An
FFO supports a balanced weight distribution in the plantar area and arch, and aids in
efficient shock absorption, including the ground reaction generated during walking or
running, thus reducing pain and unstable joint motion9).As noted above, research and analysis have been conducted with use of FFOs in walking, and
on the resulting performance and effects on kinematic functions. However, research studies
on changes in ankle joint motion in the coronal plane during the gait cycle through the body
center have not been reported. In this study, the effects of use of FFOs on changes in the
ankle angle in the coronal plane during the midstance phase of the gait cycle in young
adults with flatfoot were examined using the Vicon Motion System (Vicon, Oxford, UK).
SUBJECTS AND METHODS
This study was conducted from January 1 to 31, 2016, and included 15 college students
enrolled in University K, in Cheonan City, Korea. The study participants had no
musculoskeletal disease, and were diagnosed with flatfoot, with a calcaneal pitch angle less
than 5° on radiograph. The subjects fully understood the study, and provided written,
informed consent. This study was approved by the Clinical Test Screening Committee at Korea
Nazarene University, and was reviewed according to the Declaration of Helsinki. The general
characteristics of the research subjects who participated in this study are summarized in
Table 1.
Table 1.
General characteristics of the participants
Subjects (n=15)
Gender (M/F)
9 / 6
Age (years)
22.1 ± 3.3
Height (cm)
163.3 ± 4.1
Weight (kg)
62.3 ± 3.1
Calcaneal pitch angle (°)
2.8 ± 1.1
Values are the mean ± standard deviation (SD).
Values are the mean ± standard deviation (SD).The FFOs used by the subjects in this study were customized for each individual’s foot
shape and created with thermoplastic materials. A high-density resistance elastic pad, cup
sole for the plantar arch, low-elasticity pad for shock absorption in the heel, and
ethylene-vinyl acetate (EVA) were used to create the FFOs. When designing the foot orthotic
for a subject, the researcher positioned the heel bone vertical to the ground and allowed
the subtalar joint to maintain its natural position. While preventing pronation and
excessive movement of the feet, measurements were taken and an evaluation was performed with
weight loaded under the realigned condition of the foot. Next, the orthotic was cast, and Al
foots Inc. in Korea (Short leg brevis, Daeho, Korea) was commissioned for its fabrication.
Specifically, the experimenter measured and evaluated the subjects’ feet and molded both
foot shapes using Pedilen foam. (Short leg brevis, Daeho, Korea) With a prepared positive
plaster model, correction was performed (checking pressure points or sensitive parts of the
feet), followed by shell production and modeling with thermoplastic. Next, posting and
grinding (trimming and alignment adjustment) were performed and the production of the foot
orthotic was finalized with a covering material10,
11).The study equipment consisted of six MX-F40 cameras (Vicon, Hansung, Korea), two OR6-7
force plates (Scan, AMTI, USA), and Nexus software. (Scan, AMTI, USA) Each MX camera
transforms two-dimensional images obtained from optical markers into three-dimensional (3D)
images, so that in addition to the location data for the markers, measurements for each
segment of the body can be obtained. It is capable of measurement up to 2,000 fps. The force
plates express the ground reaction force of both feet during walking as vectors. An Ultranet
system (Scan, AMTI, USA) synchronized the mechanical motor data from the camera and the
kinematic data from the force plate into the same frame12, 13).To compute the ankle joint angle, a Plug-in Gait model (Scan, AMTI, USA), based on the
Newington-Helen Hayes gait model, was used. This was measured with a 3D motion capture
device from the Vicon Motion System. The local coordinate system of each segment was created
using the 3D spatial coordinates of each measured marker point, and a Euler algorithm was
derived. Each gait cycle was differentiated using the heel strike as a standard, and one
gait cycle of walking from each subject was extracted for time normalization12).In this experiment, only the results of the midstance were derived, where the body weight
has the greatest effect during the gait cycle. To measure the changes in ankle joint angle
in this study, the subjects walked on a prefabricated walkway, and their gait was analyzed
with a high-performance 3D camera using the Vicon Motion System before and after use of the
customized FFOs. Experiments were performed at the front of the subject’s feet and the
subject maintained a straight posture with both feet spreading as shoulder width. Markers on
the proximal part of 2nd toe heads and the frontal part of navicular bones on both sides
were used to measure the ankle angle of the midstance during a gait cycle. The differences
between the left and right ankle joint angles were calculated by quantifying the dynamic
changes. All subjects repeated the preliminary motions three times to adjust to the
experiment. The mean data of three trials were used in the statistical analysis. The
Statistical Package for the Social Sciences Windows 16.0 was used for the data analysis.
Changes in the ankle joint angle after use of FFOs were analyzed with a paired comparison
t-test, and the individual left and right changes in the ankle joint angles were analyzed
with an independent comparison t-test. The statistical significance level was set at
p<0.05.
RESULTS
After use of the orthotics by the experimental group, significant increases in the left and
right ankle joint angles were observed in the midstance of the gait cycle (p<0.05).
However, the difference between the left and right ankle joint angles showed no significant
change (p>0.05) (Table 2).
Table 2.
Ankle joint angle before and after use of foot orthotics
Midstance (°)
Before
After
Right
3.5 ± 0.3
10.2 ± 0.8*
Left
2.3 ± 0.5
11.5 ± 0.6*
Values are Mean ± SD, *Significant difference from the pre-test value, p<0.05
Values are Mean ± SD, *Significant difference from the pre-test value, p<0.05
DISCUSSION
This study investigated changes in the ankle joint angle during the midstance phase of the
gait cycle after the use of proprietary foot orthotics by 15 college students diagnosed with
flatfoot. The flatfoot was due to the change in the position of the navicular bone caused by
various congenital abnormalities in the ligaments and joints. An FFO can reduce the height
change of the foot arch, and prevents its collapse during dynamic movement. One study
reported that FFOs conserve energy during walking by reducing fatigue in the foot muscles,
which is frequently observed among flatfoot patients14). Based on this study, FFOs were fitted, and the subjects showed
significant increases in the left and right ankle joint angles in the midstance phase after
use of the orthotics. This result suggests that the use of proper FFOs by subjects with
flatfoot can relieve tension in the sole muscles and fascia exposed to severe stress in the
midstance phase of the flatfoot gait. FFO use would maintain the normal plantar arch, reduce
eversion of the ankle joint, and move inversion closer to the normal angle. The wearing of
the orthosis increased the angle by relaxing the tension of the muscles of the sole and the
fascia which were severely stressed than the normal in the middle stance of the flat walking
and maintaining the bow shape of the normal sole.Wu15) reported that orthotics can be used
for foot alignment and support, prevention and correction of foot deformities, and
improvement of foot function. Orthotics help to evenly disperse shock on the sole by
compensating for functional insufficiencies in the flat foot during each phase of
walking16). If individuals with flatfoot
develop disorders of the joints and feet, FFOs can alter the walking mechanism, which
consequently affects the other lower limb joints17). FFOs return abnormally altered joints to their normal anatomy.
Therefore, use of FFOs moves the changed foot arch in the sagittal plane of the ankle joint
to the normal range. Previous studies reported that the use of proprietary FFOs resulted in
near-normal motion in the lower limb and foot joints, similar to the changes observed in the
ankle joint angle in this study. However, only 15 young adults participated in this study,
limiting the applicability to other age groups. Further research on the use of FFOs based on
the findings of this study should investigate 3D motion in the ankle joint.