Stefanie Ehrbar1, Alexander Jöhl2, Adrianna Tartas3, Luisa Sabrina Stark4, Oliver Riesterer4, Stephan Klöck4, Matthias Guckenberger4, Stephanie Tanadini-Lang4. 1. Department of Radiation Oncology, University Hospital Zurich (USZ), Switzerland; University of Zurich, Switzerland. Electronic address: stefanie.ehrbar@usz.ch. 2. Department of Radiation Oncology, University Hospital Zurich (USZ), Switzerland; Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Switzerland. 3. Department of Radiation Oncology, University Hospital Zurich (USZ), Switzerland; University of Warsaw, Faculty of Physics, Poland. 4. Department of Radiation Oncology, University Hospital Zurich (USZ), Switzerland; University of Zurich, Switzerland.
Abstract
PURPOSE: Respiratory motion-management techniques (MMT) aim to ensure tumor dose coverage while sparing lung tissue. Dynamic treatment-couch tracking of the moving tumor is a promising new MMT and was compared to the internal-target-volume (ITV) concept, the mid-ventilation (MidV) principle and the gating approach in a planning study based on 4D dose calculations. METHODS: For twenty patients with lung lesions, planning target volumes (PTV) were adapted to the MMT and stereotactic body radiotherapy treatments were prepared with the 65%-isodose enclosing the PTV. For tracking, three concepts for target volume definition were considered: Including the gross tumor volume of one phase (single-phase tracking), including deformations between phases (multi-phase tracking) and additionally including tracking latencies of a couch tracking system (reliable couch tracking). The accumulated tumor and lung doses were estimated with 4D dose calculations based on 4D-CT datasets and deformable image registration. RESULTS: Single-phase tracking showed the lowest ipsilateral lung Dmean (median: 3.3Gy), followed by multi-phase tracking, gating, reliable couch tracking, MidV and ITV concepts (3.6, 3.8, 4.1, 4.3 and 4.8Gy). The 4D dose calculations showed the MidV and single-phase tracking overestimated the target mean dose (-2.3% and -1.3%), while it was slightly underestimated by the other MMT (<+1%). CONCLUSION: The ITV concept ensures tumor coverage, but exposes the lung tissue to a higher dose. The MidV, gating and tracking concepts were shown to reduce the lung dose. Neglecting non-translational changes of the tumor in the target volume definition for tracking results in a slightly reduced target coverage. The slightly inferior dose coverage for MidV should be considered when applying this technique clinically.
PURPOSE: Respiratory motion-management techniques (MMT) aim to ensure tumor dose coverage while sparing lung tissue. Dynamic treatment-couch tracking of the moving tumor is a promising new MMT and was compared to the internal-target-volume (ITV) concept, the mid-ventilation (MidV) principle and the gating approach in a planning study based on 4D dose calculations. METHODS: For twenty patients with lung lesions, planning target volumes (PTV) were adapted to the MMT and stereotactic body radiotherapy treatments were prepared with the 65%-isodose enclosing the PTV. For tracking, three concepts for target volume definition were considered: Including the gross tumor volume of one phase (single-phase tracking), including deformations between phases (multi-phase tracking) and additionally including tracking latencies of a couch tracking system (reliable couch tracking). The accumulated tumor and lung doses were estimated with 4D dose calculations based on 4D-CT datasets and deformable image registration. RESULTS: Single-phase tracking showed the lowest ipsilateral lung Dmean (median: 3.3Gy), followed by multi-phase tracking, gating, reliable couch tracking, MidV and ITV concepts (3.6, 3.8, 4.1, 4.3 and 4.8Gy). The 4D dose calculations showed the MidV and single-phase tracking overestimated the target mean dose (-2.3% and -1.3%), while it was slightly underestimated by the other MMT (<+1%). CONCLUSION: The ITV concept ensures tumor coverage, but exposes the lung tissue to a higher dose. The MidV, gating and tracking concepts were shown to reduce the lung dose. Neglecting non-translational changes of the tumor in the target volume definition for tracking results in a slightly reduced target coverage. The slightly inferior dose coverage for MidV should be considered when applying this technique clinically.
Authors: Martin J Menten; Jonathan K Mohajer; Rahul Nilawar; Jenny Bertholet; Alex Dunlop; Angela U Pathmanathan; Michel Moreau; Spencer Marshall; Andreas Wetscherek; Simeon Nill; Alison C Tree; Uwe Oelfke Journal: Radiother Oncol Date: 2020-01-10 Impact factor: 6.280
Authors: Kai Joachim Borm; Markus Oechsner; Moritz Wiegandt; Andreas Hofmeister; Stephanie E Combs; Marciana Nona Duma Journal: BMC Cancer Date: 2018-07-24 Impact factor: 4.430