Literature DB >> 28586501

Biomechanical Characterization of Subclinical Keratoconus Without Topographic or Tomographic Abnormalities.

Riccardo Vinciguerra, Renato Ambrósio, Cynthia J Roberts, Claudio Azzolini, Paolo Vinciguerra.   

Abstract

PURPOSE: To present a case series of patients with subclinical keratoconus with normal topometric (anterior curvature) and tomographic findings in one eye who showed abnormalities detected by Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) in vivo biomechanical assessment.
METHODS: All patients had a complete ophthalmic examination, including the Corvis ST biomechanical measurements, optical tomography, and pachymetry with Pentacam (Oculus Optikgeräte GmbH), and Placido-based topography with either the Nidek (OPD III Nidek, Gamagori, Japan) or CSO platform (Costruzione Strumenti Oftalmici, Florence, Italy). Inclusion criteria were a clinical diagnosis of ectasia in one eye and normal topometric and tomographic findings in the fellow eye (subclinical keratoconus), including a Belin/Ambrósio Enhanced Ectasia total deviation index from the Pentacam with less than 1.6 standard deviations from normative values and a Corvis Biomechanical Index score of greater than 0.5 in both eyes.
RESULTS: Tomographic and topographic analysis was normal in one eye and abnormal in the fellow eye in 12 patients. The biomechanical results with the Corvis Biomechanical Index were shown to be abnormal in both eyes of all patients and aided the diagnosis.
CONCLUSIONS: Biomechanical analysis showed abnormalities, whereas tomography and topography were normal. Basing on these findings, the authors suggest the use of biomechanics as an additional diagnostic tool. [J Refract Surg. 2017;33(6):399-407.]. Copyright 2017, SLACK Incorporated.

Entities:  

Mesh:

Year:  2017        PMID: 28586501     DOI: 10.3928/1081597X-20170213-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  28 in total

1.  Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus.

Authors:  Haci Hasan Ozkan; Mustafa Koc; Hasan Kiziltoprak; Kemal Tekin; Emre Aydemir
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

2.  [Evaluation of corneal biomechanics in keratoconus using dynamic ultra-high-speed Scheimpflug measurements].

Authors:  S Brettl; P Franko Zeitz; T A Fuchsluger
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

3.  Distinguishing Highly Asymmetric Keratoconus Eyes Using Combined Scheimpflug and Spectral-Domain OCT Analysis.

Authors:  Eric S Hwang; Claudia E Perez-Straziota; Sang Woo Kim; Marcony R Santhiago; J Bradley Randleman
Journal:  Ophthalmology       Date:  2018-07-25       Impact factor: 12.079

Review 4.  [Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters : A praxis-related overview].

Authors:  R Herber; N Terai; K R Pillunat; F Raiskup; L E Pillunat; E Spörl
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

5.  Distinguishing Highly Asymmetric Keratoconus Eyes Using Dual Scheimpflug/Placido Analysis.

Authors:  Oren Golan; Andre L Piccinini; Eric S Hwang; Ildamaris Montes De Oca Gonzalez; Mark Krauthammer; Sumitra S Khandelwal; David Smadja; J Bradley Randleman
Journal:  Am J Ophthalmol       Date:  2019-02-02       Impact factor: 5.258

6.  Evaluation of Intraocular Pressure and Other Biomechanical Parameters to Distinguish between Subclinical Keratoconus and Healthy Corneas.

Authors:  Cristina Peris-Martínez; María Amparo Díez-Ajenjo; María Carmen García-Domene; María Dolores Pinazo-Durán; María José Luque-Cobija; María Ángeles Del Buey-Sayas; Susana Ortí-Navarro
Journal:  J Clin Med       Date:  2021-04-28       Impact factor: 4.241

7.  Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications.

Authors:  Renato Ambrósio; Fernando Faria Correia; Bernardo Lopes; Marcella Q Salomão; Allan Luz; Daniel G Dawson; Ahmed Elsheikh; Riccardo Vinciguerra; Paolo Vinciguerra; Cynthia J Roberts
Journal:  Open Ophthalmol J       Date:  2017-07-31

8.  Spatially-resolved Brillouin spectroscopy reveals biomechanical abnormalities in mild to advanced keratoconus in vivo.

Authors:  Peng Shao; Amira M Eltony; Theo G Seiler; Behrouz Tavakol; Roberto Pineda; Tobias Koller; Theo Seiler; Seok-Hyun Yun
Journal:  Sci Rep       Date:  2019-05-16       Impact factor: 4.379

Review 9.  A Review of Structural and Biomechanical Changes in the Cornea in Aging, Disease, and Photochemical Crosslinking.

Authors:  Brecken J Blackburn; Michael W Jenkins; Andrew M Rollins; William J Dupps
Journal:  Front Bioeng Biotechnol       Date:  2019-03-29

Review 10.  Dynamic corneal deformation response and integrated corneal tomography.

Authors:  Marcella Q Salomão; Ana Luisa Hofling-Lima; Fernando Faria-Correia; Bernardo Teixeira Lopes; Sandra Rodrigues-Barros; Cynthia J Roberts; Renato Ambrósio
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

View more