| Literature DB >> 28585489 |
Ozlem Ozkaya Akagunduz1, Suzan Guven Yilmaz2, Deniz Yalman1, Berna Yuce3, Elif Demirkilinc Biler2, Filiz Afrashi2, Mustafa Esassolak1.
Abstract
PURPOSE: To evaluate the radiation dose-volume effects of optic nerves and chiasm by visual psychophysical, electrophysiologic tests, and optical coherence tomography in patients with locally advanced nasopharyngeal carcinoma.Entities:
Keywords: anterior visual pathways; electrophysiologic tests; optic nerves and chiasm; radiation dose–volume effects; radiation optic neuropathy
Year: 2017 PMID: 28585489 PMCID: PMC5762056 DOI: 10.1177/1533034617711613
Source DB: PubMed Journal: Technol Cancer Res Treat ISSN: 1533-0338
Figure 1.Typical optical coherence tomography (OCT) report (patient number 2, a 49-year-old male). The upper image illustrates the significance and thickness maps of retinal nerve fiber layer (RNFL) and color photos for the right oculus dexter (OD) and left oculus sinister (OS) eye, respectively. RNFL thickness is plotted with respect to a circumferential retinal map on the temporal-superior-nasal-inferior-temporal (TSNIT) quadrants (middle image). RNFL analysis demonstrating measurements within normative limits in both eyes, designated by a “stoplight” designation (bottom image). Note the quadrant and clockface sector measures of RNFL thickness.
Ophthalmological Evaluation Results of the Patients.
| Patient No. | Laterality | Visual Acuity | Visual Field | Contrast Sensitivity | VEP Latency, milliseconds | VEP Amplitude, µV | RNFL Thickness | Optic Neuropathy With or Without Retinopathy |
|---|---|---|---|---|---|---|---|---|
| 1 | Left eye | 1.0 | 2 | 1 | 107 | 5.6 | 94 | No |
| Right eye | 1.0 | 1 | 1 | 109 | 8.5 | 94 | No | |
| 2 | Left eye | 0.4 | 4 | 3 | 103 | 3.5 | 103 | Yes |
| Right eye | 1.0 | 2 | 2 | 105 | 4.6 | 100 | Yes | |
| 3 | Left eye | 0.1 | 3 | 3 | 111 | 9.2 | 98 | No |
| Right eye | 0.05 | 4 | 3 | 114 | 8.3 | 99 | No | |
| 4 | Left eye | 1.0 | 1 | 1 | 103 | 16.1 | 110 | No |
| Right eye | 1.0 | 1 | 1 | 106 | 14.4 | 122 | No | |
| 5 | Left eye | 1.0 | 1 | 1 | 94 | 8.5 | 99 | No |
| Right eye | 1.0 | 3 | 1 | 95 | 6.7 | 96 | No | |
| 6 | Left eye | 0.7 | 3 | 1 | 94 | 6.4 | 96 | No |
| Right eye | 1.0 | 2 | 1 | 95 | 3.3 | 92 | No | |
| 7 | Left eye | 1.0 | 2 | 1 | 98 | 9.9 | 99 | No |
| Right eye | 1.0 | 2 | 1 | 98 | 12.1 | 51 | No | |
| 8 | Left eye | 1.0 | 2 | 1 | 107 | 9.9 | 97 | No |
| Right eye | 0.9 | 2 | 1 | 108 | 8.1 | 94 | No | |
| 9 | Left eye | 0.9 | 2 | 1 | 108 | 2.3 | 92 | No |
| Right eye | 1.0 | 2 | 1 | 109 | 3.6 | 98 | No | |
| 10 | Left eye | 1.0 | 4 | 3 | 143 | 10.4 | 94 | Yes |
| Right eye | 0.1 | 4 | 2 | 148 | 5.2 | 91 | Yes | |
| 11 | Left eye | 1.0 | 1 | 1 | 109 | 11.1 | 92 | No |
| Right eye | 1.0 | 1 | 1 | 103 | 11.1 | 78 | No | |
| 12 | Left eye | 1.0 | 3 | 3 | 114 | 6.9 | 90 | No |
| Right eye | 1.0 | 4 | 3 | 112 | 4.4 | 77 | No | |
| 13 | Left eye | 1.0 | 2 | 3 | 109 | 2.9 | 92 | No |
| Right eye | 1.0 | 2 | 3 | 106 | 5.6 | 92 | No | |
| 14 | Left eye | 0.9 | 3 | 2 | 95 | 2.1 | 83 | No |
| Right eye | 0.9 | 3 | 2 | 108 | 3.2 | 95 | No | |
| 15 | Left eye | 0.4 | 1 | 1 | 101 | 5.2 | 85 | No |
| Right eye | 0.03 | 4 | 3 | 139 | 4.3 | 85 | Yes | |
| 16 | Left eye | 1.0 | 2 | 1 | 98 | 12.3 | 51 | No |
| Right eye | 1.0 | 2 | 1 | 97 | 9.9 | 99 | No | |
| 17 | Left eye | 0.3 | 4 | 3 | 127 | 2.2 | 93 | Yes |
| Right eye | 0.6 | 4 | 3 | 127 | 4.3 | 95 | Yes | |
| 18 | Left eye | 1.0 | 2 | 1 | 111 | 4.1 | 96 | No |
| Right eye | 0.08 | Unable | Unable | 156 | 1.2 | 96 | Yes | |
| 19 | Left eye | 1.0 | 4 | 3 | 98 | 16.1 | 94 | No |
| Right eye | 1.0 | 4 | 3 | 103 | 1.5 | 95 | No | |
| 20 | Left eye | 1.0 | 2 | 2 | 105 | 8.3 | 81 | No |
| Right eye | 0.9 | 3 | 2 | 99 | 7.6 | 99 | No |
Abbreviations: RNFL, retinal nerve fiber layer; VEP, visual evoked potential.
Figure 2.Correlation between Dmean (A), Dmax (B), and visual evoked potential (VEP) latency for optic nerves.
The Effect of Radiation Dose–Volume Parameters on Ophthalmologic Tests for Optic Nerves.a
| Visual Tests | Median Score | Odds Ratio | Confidence Interval (95% CI) |
|
|---|---|---|---|---|
|
| ||||
| V55 <50% vs ≥50% | 1.0 vs 0.6 | 18.85 | 1.92-184.63 | .002 |
| Dmean <50 Gy vs ≥50 Gy | 1.0 vs 0.4 | 28.80 | 2.81-188.80 | .001 |
| D5 <55 Gy vs ≥55 Gy | 1.0 vs 0.7 | 13.33 | 1.39-127.57 | .008 |
| Dmax <60 Gy vs ≥60 Gy | 1.0 vs 0.7 | 13.33 | 1.39-127.57 | .008 |
|
| ||||
| Dmean <50 Gy vs ≥50 Gy | 94 vs 95 | 1.03 | 0.21-5.01 | .965 |
| Dmax <60 Gy vs ≥60 Gy | 94 vs 95 | 0.62 | 0.14-2.71 | .529 |
|
| ||||
| V55 <50% vs ≥50% | 2 vs 3 | 4.23 | 1.45-39.87 | .045 |
| Dmean <50 Gy vs ≥50 Gy | 2 vs 3 | 0.72 | 0.56-0.91 | .050 |
| D5 <55 Gy vs ≥55 Gy | 2 vs 3 | 5.60 | 0.59-52.53 | .102 |
| Dmax <60 Gy vs ≥60 Gy | 2 vs 3 | 5.60 | 0.59-52.53 | .102 |
|
| ||||
| V55 <50% vs ≥50% | 1 vs 3 | 5.14 | 1.17-22.48 | .024 |
| Dmean <50 Gy vs ≥50 Gy | 1 vs 3 | 11.57 | 1.98-67.49 | .003 |
| D5 <55 Gy vs ≥55 Gy | 1 vs 3 | 5.00 | 0.19-20.92 | .123 |
| Dmax <60 Gy vs ≥60 Gy | 1 vs 3 | 5.00 | 0.19-20.92 | .123 |
|
| ||||
| V55 <50% vs ≥50% | 101 vs 110 | 2.48 | 0.61-10.05 | .096 |
| Dmean <50 Gy vs ≥50 Gy | 100 vs 117 | 26.62 | 4.52-155.34 | <.001 |
| D5 <55 Gy vs ≥55 Gy | 100 vs 113 | 7.71 | 1.71-36.63 | .005 |
| Dmax <60 Gy vs ≥60 Gy | 99 vs 112 | 9.52 | 2.01-44.91 | .002 |
|
| ||||
| V55 <50% vs ≥50% | 8.4 vs 5.3 | 1.60 | 0.34-7.45 | .54 |
| Dmean <50 Gy vs ≥50 Gy | 8.5 vs 4.8 | 1.18 | 0.23-5.96 | .83 |
| D5 <55 Gy vs ≥55 Gy | 8.4 vs 6.0 | 1.16 | 0.25-5.33 | .84 |
| Dmax <60 Gy vs ≥60 Gy | 8.4 vs 6.2 | 2.12 | 0.46-9.80 | .32 |
Abbreviations: CI, confidence interval; OR, odds ratio; RNFL, retinal nerve fiber layer; VEP, visual evoked potential.
aVisual acuity: 1.0: normal, <1.0: abnormal; Visual field: Grade 2: peripheral defects outside the central 30° field, grade 3, defects located in the central 30° field; contrast sensitivity: grade 1: normal, grade 3: under the normal line beginning from low spatial frequencies (1 cycle/degree) for each eye. VEP latency: 106 ± 3 milliseconds; VEP amplitude: 9 ± 4 µV; odds ratio: cross tabulations were prepared, and odds ratios were calculated using the formula, OR = a × d/b × c.
Figure 3.Correlation between Dmean (A), Dmax (B), and visual evoked potential (VEP) latency for chiasm.
The Effect of Radiation Dose–Volume Parameters on Ophthalmologic Tests for Chiasm.a
| Visual Tests | Median Score | Odds Ratio | Confidence Interval (95% CI) |
|
|---|---|---|---|---|
|
| ||||
| V55 <50% vs ≥50% | 1.0 vs 0.3 | 13.33 | 1.39-127.57 | .008 |
| Dmean <50 Gy vs ≥50 Gy | 1.0 vs 0.7 | 1.63 | 1.13-2.36 | .003 |
| D5 <55 Gy vs ≥55 Gy | 1.0 vs 0.7 | 1.41 | 1.09-1.82 | .037 |
| Dmax <60 Gy vs ≥60 Gy | 1.0 vs 0.8 | 1.46 | 1.10-1.95 | .019 |
|
| ||||
| Dmean <50 Gy vs ≥50 Gy | 90 vs 93 | 1.00 | 0.23-4.30 | 1.00 |
| Dmax <60 Gy vs ≥60 Gy | 94 vs 89 | 0.58 | 0.12-2.78 | .49 |
|
| ||||
| V55 <50% vs ≥50% | 2 vs 3 | 4.23 | 4.50-39.87 | .180 |
| Dmean <50 Gy vs ≥50 Gy | 2 vs 3 | 8.51 | 0.90-80.02 | .035 |
| D5 <55 Gy vs ≥55 Gy | 2 vs 3 | 3.50 | 0.63-19.23 | .137 |
| Dmax <60 Gy vs ≥60 Gy | 2 vs 3 | 5.62 | 0.44-22.53 | .102 |
|
| ||||
| V55 <50% vs ≥50% | 1 vs 3 | 3.00 | 0.75-11.86 | .112 |
| Dmean <50 Gy vs ≥50 Gy | 1 vs 3 | 7.00 | 1.59-30.80 | .007 |
| D5 <55 Gy vs ≥55 Gy | 1 vs 3 | 2.00 | 0.47-8.46 | .343 |
| Dmax <60 Gy vs ≥60 Gy | 1 vs 3 | 5.00 | 1.19-20.92 | .023 |
|
| ||||
| V55 <50% vs ≥50% | 101 vs 113 | 7.91 | 1.71-36.63 | .005 |
| Dmean <50 Gy vs ≥50 Gy | 97 vs 110 | 9.35 | 1.71-51.03 | .005 |
| D5 <55 Gy vs ≥55 Gy | 99 vs 110 | 3.78 | 0.69-20.51 | .109 |
| Dmax <60 Gy vs ≥60 Gy | 99 vs 107 | 5.10 | 0.94-27.54 | .045 |
|
| ||||
| V55 <50% vs ≥50% | 8.5 vs 5.0 | 1.16 | 0.25-5.33 | .845 |
| Dmean <50 Gy vs ≥50 Gy | 9.3 vs 5.2 | 2.5 | 0.51-12.13 | .248 |
| D5 <55 Gy vs ≥55 Gy | 7.6 vs 5.6 | 1.0 | 0.20-4.95 | 1.00 |
| Dmax <60 Gy vs ≥60 Gy | 8.9 vs 6.7 | 1.37 | 0.28-6.70 | .693 |
Abbreviations: CI, confidence interval; OR, odds ratio; RNFL, retinal nerve fiber layer; VEP, visual evoked potential.
a Visual acuity: 1.0: normal, <1.0: abnormal; visual field: grade 2: peripheral defects outside the central 30° field, grade 3: defects located in the central 30° field; contrast sensitivity: grade 1: normal, grade 3: under the normal line beginning from low spatial frequencies (1 cycle/degree) for each eye. VEP latency: 106 ± 3 milliseconds; VEP amplitude: 9 ± 4 µV; odds ratio: cross tabulations were prepared, and odds ratios were calculated using the formula, OR = a × d/b × c.