Literature DB >> 24834838

Contrast sensitivity in relapsing-remitting multiple sclerosis assessed by sine-wave gratings and angular frequency stimuli.

Jákina G Vieira-Gutemberg1, Liana C Mendes-Santos2, Melyssa K Cavalcanti-Galdino3, Natanael A Santos4, Maria Lúcia DE Bustamante Simas1.   

Abstract

Previous studies have shown that multiple sclerosis (MS) affects the visual system, mainly by reducing contrast sensitivity (CS), a function that can be assessed by measuring contrast sensitivity function (CSF). To this end, we measured both the CSF for sine-wave gratings and angular frequency stimuli with 20 participants aged between 21 and 44 years, of both genders, with normal or corrected to normal visual acuity. Of these 20 participants, there were 10 volunteers with clinically defined MS of the relapsing-remitting clinical form, with no history of optic neuritis (ON), as well as 10 healthy volunteers who served as the control group (CG). We used a forced-choice detection paradigm. The results showed reduced CS to both classes of stimuli. Differences were found for sine-wave gratings at spatial frequencies of 0.5, 1.25, and 2.5 cycles per degree (cpd) (P < 0.002) and for angular frequency stimuli of 4, 24, and 48 cycles/360° (P < 0.05). On the one hand, comparing the maxima of the respective CSFs, the CS to angular frequency stimuli (24 cycles/360°) was 1.61-fold higher than that of the CS to vertical sine-wave gratings (4.0 cpd) in the CG; for the MS group, these values were 1.55-fold higher. On the other hand, CS in the MS group attained only 75% for 24 cycles/360° and 78% for 4.0 cpd of the 100% CS estimates found for the CG at the peak frequencies. These findings suggest that MS affects the visual system, mostly at its maximum contrast sensitivities. Also, since angular frequencies and sine-wave gratings operate at distinct levels of contrast in the visual system, MS seems to affect CS at both high and low levels of contrast.

Entities:  

Mesh:

Year:  2014        PMID: 24834838     DOI: 10.1017/S0952523814000182

Source DB:  PubMed          Journal:  Vis Neurosci        ISSN: 0952-5238            Impact factor:   3.241


  4 in total

1.  Evaluation of the Radiation Dose-Volume Effects of Optic Nerves and Chiasm by Psychophysical, Electrophysiologic Tests, and Optical Coherence Tomography in Nasopharyngeal Carcinoma.

Authors:  Ozlem Ozkaya Akagunduz; Suzan Guven Yilmaz; Deniz Yalman; Berna Yuce; Elif Demirkilinc Biler; Filiz Afrashi; Mustafa Esassolak
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

2.  Introducing a new method to assess vision: Computer-adaptive contrast-sensitivity testing predicts visual functioning better than charts in multiple sclerosis patients.

Authors:  J P Stellmann; K L Young; J Pöttgen; M Dorr; C Heesen
Journal:  Mult Scler J Exp Transl Clin       Date:  2015-07-21

3.  Functional Evaluation of the Visual Pathway in Patients with Multiple Sclerosis Using a Multifunction Stimulator Monitor.

Authors:  M Satue; L Jarauta; J Obis; M Cipres; M J Rodrigo; C Almarcegui; I Dolz; J R Ara; J Martin; L E Pablo; E Garcia-Martin
Journal:  J Ophthalmol       Date:  2019-09-18       Impact factor: 1.909

4.  Restricted Spatial Windows of Visibility in Myalgic Encephalomyelitis (ME).

Authors:  Nadia S Ahmed; Irene Gottlob; Frank A Proudlock; Claire V Hutchinson
Journal:  Vision (Basel)       Date:  2018-01-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.