Ahmed Ali Alderazi1, Mary Lynch2. 1. Department of Medicine, Royal College of Surgeons in Ireland, Medical University of Bahrain, Busiateen, Bahrain. 2. Mohammed bin Khalifa Cardiac Centre, Bahrain.
Abstract
BACKGROUND: In response to growing concerns regarding the overuse of coronary computed tomography angiography (CCTA) in the clinical setting, multiple societies, including the American College of Cardiology Foundation, have jointly published revised criteria regarding the appropriate use of this imaging modality. However, previous research indicates significant discrepancies in the rate of adherence to these guidelines. AIM: To assess the appropriateness of CCTA referrals in a tertiary cardiac center in Bahrain. METHODS: This retrospective clinical audit examined the records of patients referred to CCTA between the April 1, 2015 and December 31, 2015 in Mohammed bin Khalifa Cardiac Center. Using information from medical records, each case was meticulously audited against guidelines to categorize it as appropriate, inappropriate, or uncertain. RESULTS: Of the 234 records examined, 176 (75.2%) were appropriate, 47 (20.1%) were uncertain, and 11 (4.7%) were inappropriate. About 74.4% of all referrals were to investigate coronary artery disease (CAD). The most common indication that was deemed appropriate was the detection of CAD in the setting of suspected ischemic equivalent in patients with an intermediate pretest probability of CAD (65.9%). Most referrals deemed inappropriate were requested to detect CAD in asymptomatic patients at low or intermediate risk of CAD (63.6%). CONCLUSION: This audit demonstrates a relatively low rate of inappropriate CCTA referrals, indicating the appropriate and efficient use of this resource in the Mohammed bin Khalifa Cardiac Center. Agreement on and reclassification of "uncertain" cases by guideline authorities would facilitate a deeper understanding of referral appropriateness.
BACKGROUND: In response to growing concerns regarding the overuse of coronary computed tomography angiography (CCTA) in the clinical setting, multiple societies, including the American College of Cardiology Foundation, have jointly published revised criteria regarding the appropriate use of this imaging modality. However, previous research indicates significant discrepancies in the rate of adherence to these guidelines. AIM: To assess the appropriateness of CCTA referrals in a tertiary cardiac center in Bahrain. METHODS: This retrospective clinical audit examined the records of patients referred to CCTA between the April 1, 2015 and December 31, 2015 in Mohammed bin Khalifa Cardiac Center. Using information from medical records, each case was meticulously audited against guidelines to categorize it as appropriate, inappropriate, or uncertain. RESULTS: Of the 234 records examined, 176 (75.2%) were appropriate, 47 (20.1%) were uncertain, and 11 (4.7%) were inappropriate. About 74.4% of all referrals were to investigate coronary artery disease (CAD). The most common indication that was deemed appropriate was the detection of CAD in the setting of suspected ischemic equivalent in patients with an intermediate pretest probability of CAD (65.9%). Most referrals deemed inappropriate were requested to detect CAD in asymptomatic patients at low or intermediate risk of CAD (63.6%). CONCLUSION: This audit demonstrates a relatively low rate of inappropriate CCTA referrals, indicating the appropriate and efficient use of this resource in the Mohammed bin Khalifa Cardiac Center. Agreement on and reclassification of "uncertain" cases by guideline authorities would facilitate a deeper understanding of referral appropriateness.
Over the past two decades, computed tomography has undergone an accelerated improvement in capabilities relative to other imaging modalities,[1] with various improvements witnessed in terms of scan duration and temporal and spatial resolution. These advances enabled the imaging of small and fast moving structures, essentially overcoming the challenge of imaging the coronary arteries in a beating heart. The ability of coronary computed tomography angiography (CCTA) to noninvasively assess coronary arteries has generated widespread enthusiasm, as reflected by its rapid growth and dissemination.[2]However, despite the proven value of CCTA in evaluating numerous medical conditions,[234] there have been growing concerns regarding its overuse in the clinical setting, which is not only associated with a significant financial strain on health services, but also the potential to expose patients to unnecessary radiation. The typical radiation dose for a CCTA study varies widely – from < 1 mSv in a FLASH mode CCTA,[5] through 2–3 mSv for “Step-and-Shoot” protocol[6] to a median dose of 12 mSv for a helical CCTA.[7]Consequently, effort has been made to maximize the rational utilization of this growing imaging modality by The American College of Cardiology Foundation in coordination with multiple specialty and sub-specialty societies, which have jointly published revised CCTA appropriate use criteria (AUC) in 2010.[3]Nevertheless, evidence still exists of suboptimal use of this modality in various institutions, with previous data suggesting that the rate of inappropriate use varies between 5% and 25%.[8]The present study sought to audit the appropriateness of CCTA scans conducted at a tertiary cardiac center in the Kingdom of Bahrain.
METHODS
This study was designed as a retrospective audit of medical records of patients referred for CCTA in the Mohammed bin Khalifa Cardiac Center.
Study population
This study planned to examine all eligible records of patients referred to coronary CT in the time period from April 1, 2015 to December 31, 2015; this period was purposefully chosen to be prior to all physicians' knowledge of the audit to avoid the potential for Hawthorne effect.
Data collection and analysis
Pertinent patient data was directly entered into an Excel spreadsheet (Microsoft Corp., Redmond, WA, USA) from two sources:CT scan records for identifying details of patients referred to coronary CT, along with details of the CT scan procedurePatient medical records for additional details regarding referred patients, including family history, previous test results, reason for referral to CT, contraindications to imaging and coronary artery disease (CAD) risk scores.Patient records were irrevocably anonymized by removing or replacing all potentially identifiable data.After the information was extracted from the aforementioned sources, each case was meticulously audited against the guidelines to assess appropriateness. To ensure applicability of results, all scoring systems and definitions used are either recommended or referenced by the guidelines.The guidelines take into account a plethora of clinical information regarding each case referred to CCTA to characterize it into one of 93 clinical scenarios where coronary CT could be potentially used; each scenario is associated with a numerical score ranging from 1 to 9, which is derived from available clinical evidence and an independent technical panel of experts using a modified Delphi technique.[3] The three possible characterizations of appropriateness are appropriate (7–9), uncertain (4–6), and inappropriate (1–3).Cases where the CT scan and/or patient records were inadequate to yield an indication from the guidelines were excluded. Since this audit sought to establish the appropriateness of CCTA use, noncontrast CT scans ordered to calculate the coronary calcium score were not included. All cases were consistent with assumptions the guidelines make regarding the quality standards of CCT imaging.
Statistical analysis
Continuous variables are presented as median (Q1, Q3), whereas categorical variables are presented as frequency (% of n). Differences in the clinical characteristics of the analysis sample based on the AUC group were analyzed using the Chi-square test for categorical variables and Kruskal–Wallis test for continuous variables. Statistical significance was defined as a P < 0.05. Statistical analysis was performed using SPSS version 21.0 (IBM Corp., Chicago, Illinois, USA).
RESULTS
Study group characteristics
The audit initially identified 315 records of patients referred to coronary CT in the specified time frame. Of these records, 81 records were excluded collectively due to the cancellation of the CT scan (48 records) or insufficient information in the databases to yield an appropriate score from the guidelines (33 records); the remaining 234 records constituted the analysis sample.The majority of cancelled scans were aborted by the attending cardiologists in light of a high calcium score from a preceding noncontrast coronary CT. Other reasons for cancellation include evidence of renal insufficiency and nonideal factors for imaging, such as the inability of patients to hold their breath.The clinical characteristics of the analysis sample are illustrated in Table 1. The median age of the analysis sample was 55 years (range 15–84 years), with 55.1% of records belonging to male patients.
Table 1
Clinical characteristics of analysis sample (n=234)
Clinical characteristics of analysis sample (n=234)One patient was noted to have developed an anaphylactic reaction to contrast agent.
Reasons for referral
Overall, detection of CAD was by far the most common reported reason for referral to CCTA, with 174 (74.4%) of referrals falling into this category. The other reasons for referral are results of previous tests (20.5%), evaluation of cardiac structure and function (3.0%), and postrevascularization (2.1%).
Appropriateness of referrals
Figure 1 illustrates the proportion of referrals that fall into each AUC category.
Figure 1
Pie chart illustrating the proportion of referrals that fall into each appropriate use criteria category
Pie chart illustrating the proportion of referrals that fall into each appropriate use criteria categoryTable 2 compares the reasons for referral according to AUC category. Among referrals deemed appropriate (n = 176, 75.2%), the most common indication by far was CAD detection in patients with suspected ischemic equivalent with an intermediate pretest probability of CAD (116 cases, 65.9%). Prior test results constituted the second most common indication for referrals that were deemed appropriate (38 cases, 21.6%).
Table 2
Reported reasons for coronary computed tomography angiography referral according to appropriate use criteria category attributed to analysis sample records (n=234)
Reported reasons for coronary computed tomography angiography referral according to appropriate use criteria category attributed to analysis sample records (n=234)In contrast, referrals deemed inappropriate (n = 11, 4.7%) were predominantly requested to detect CAD in asymptomatic patients at low or intermediate risk of CAD (seven cases, 63.6%). The remainder of referrals deemed inappropriate fall into two equally contributing categories: CAD detection in suspected ischemic equivalent in patients at high risk of CAD (two cases, 18.2%) and periodic repeat testing in setting of prior test results in stable or asymptomatic patients (two cases, 18.2%).Of referrals that fall into the uncertain category (n = 47, 20.1%), the most common indications were detection of CAD in asymptomatic patients at high risk of CAD (17 cases, 36.2%) and detection of CAD in suspected ischemic equivalent in patients at low risk of CAD (15 cases, 31.9%).Table 3 illustrates the differences in clinical characteristics of records according to AUC category. In general, clinical characteristics are relatively similar in all groups, with the only statistically significant difference being symptomatic state (P < 0.001).
Table 3
Comparison of clinical characteristics of records according to appropriate use criteria category
Comparison of clinical characteristics of records according to appropriate use criteria category
DISCUSSION
This is the first reported study in Bahrain which sought to assess CCTA referral patterns according to the latest 2010 AUC guidelines. This study analyzed the records of patients referred to CCTA in a 9-month period, making it robust against the short-term temporal trends in CCTA referral patterns.In general, the results demonstrate favorable referral patterns, with a relatively high rate of appropriate use and a rate of inappropriate use that is comparable to the lowest rates reported in studies using the same guidelines[91011] [Figure 2].
Figure 2
Bar chart comparing coronary computed tomography angiography referrals in this study to those reported in other studies using the 2010 appropriate use criteria guidelines
Bar chart comparing coronary computed tomography angiography referrals in this study to those reported in other studies using the 2010 appropriate use criteria guidelinesThese results indicate proper, relatively efficient utilization of CCTA scans in the Mohammed bin Khalifa Cardiac Center that is largely in line with published guidelines.As evident from the clinical characteristics of the study sample, patients who were referred to CCTA were predominantly symptomatic with a low or intermediate risk of CAD. This further reinforces the appropriateness of the referrals as patients in this category are likely to benefit from the high-negative predictive value that CCTA offers, providing an effective method of ruling out CAD and avoiding the risks of invasive angiography.[12] Hence, it is not surprising that the detection of CAD in symptomatic patients was identified as the most common appropriate indication for referral to CCTA, both by this study and in similar studies.[1314]Referrals that fall into inappropriate AUC category also showed resemblance to those reported in similar studies; “CAD detection in asymptomatic patients with low- or intermediate-risk of CHD” constituted the majority of inappropriate indications in this study and most studies which reported this statistic.[111314] This striking similarity can possibly reflect universal physician misconceptions regarding the utilization of CCTA in this particular patient group. If so, intervention in the form of a quality improvement program is likely to be beneficial, as interventions aiming to rectify previously assessed inappropriate CCTA referrals were proven to be efficacious in significantly lowering the rates of inappropriate CCTA scans.[813] This study has demonstrated a statistically significant higher proportion of asymptomatic patients compromising the inappropriate AUC group relative to other groups (P < 0.001), indicating that paying particular heed to asymptomatic patients' clinical situation prior to their referral to CCTA may also be efficacious in decreasing inappropriate referrals.Interestingly, this study revealed that a considerable proportion of referrals were deemed “uncertain” by guidelines, echoing a universal pattern seen in similar studies.[910131415] This is a significant obstacle; one fifth of referrals analyzed fall into this category, making it impossible to appreciate or act on the appropriateness of these referrals. This highlights the need to reach a consensus on such cases to refine and update the current guidelines, which will facilitate a better understanding on the appropriateness of CCTA referrals and provide valuable guidance on how inappropriate scans can be minimized.
Study limitations
This study was conducted with the underlying assumption that all pertinent data that physicians' used to make a clinical decision is documented in the databases. Any information not documented could have resulted in misclassification. Considering the relatively thorough documentation of patient information in the databases analyzed and the exclusion of cases with clearly insufficient data, the effect of this assumption on data accuracy is expected to be limited.While the guidelines take into account a multitude of clinical parameters to yield an appropriateness score, they did not take into consideration the type of scan mode or radiation dose associated with CCTA imaging; although the variation in radiation dose for spiral CT imaging may not vary significantly between hospitals to warrant special consideration, the “Flash” scan mode of the DSCT scanner used in Mohammed bin Khalifa Cardiac Center is associated with a radiation dose of < 1 mSV.[5] Ideally, this relatively low-radiation dose should be taken into account as part of the benefit-to-risk analysis. Taking this into consideration would potentially lower the already small proportion of referrals deemed “inappropriate” by this audit.
CONCLUSION
This audit provides evidence of appropriate and efficient use of CCTA in the Mohammed bin Khalifa Cardiac Center, identifying limited room for improvement. Setting up a continuous quality improvement system that incorporates AUC guidelines is recommended to maintain and further enhance current CCTA referral patterns. Reaching a consensus on “uncertain” scenarios in the guidelines is required to gain a deeper understanding of the appropriateness of CCTA referrals.
Authors: Daniel B Mark; Daniel S Berman; Matthew J Budoff; J Jeffrey Carr; Thomas C Gerber; Harvey S Hecht; Mark A Hlatky; John McB Hodgson; Michael S Lauer; Julie M Miller; Richard L Morin; Debabrata Mukherjee; Michael Poon; Geoffrey D Rubin; Robert S Schwartz Journal: Catheter Cardiovasc Interv Date: 2010-08-01 Impact factor: 2.692
Authors: Meagan K Murphy; Thomas J Brady; Khurram Nasir; G Scott Gazelle; Fabian Bamberg; Quynh A Truong; Wilfred S Mamuya; Suhny Abbara; Thomas H Lee; Ron Blankstein Journal: J Nucl Cardiol Date: 2010-06-15 Impact factor: 5.952
Authors: Matthew J Budoff; Stephan Achenbach; Roger S Blumenthal; J Jeffrey Carr; Jonathan G Goldin; Philip Greenland; Alan D Guerci; Joao A C Lima; Daniel J Rader; Geoffrey D Rubin; Leslee J Shaw; Susan E Wiegers Journal: Circulation Date: 2006-10-02 Impact factor: 29.690
Authors: Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Tobias Krauss; Lotus Desbiolles; André Plass; Michele Genoni; Thomas G Flohr; Simon Wildermuth; Borut Marincek; Hatem Alkadhi Journal: Radiology Date: 2008-10 Impact factor: 11.105
Authors: Stephan Achenbach; Mohamed Marwan; Dieter Ropers; Tiziano Schepis; Tobias Pflederer; Katharina Anders; Axel Kuettner; Werner G Daniel; Michael Uder; Michael M Lell Journal: Eur Heart J Date: 2009-11-05 Impact factor: 29.983
Authors: Allen J Taylor; Manuel Cerqueira; John McB Hodgson; Daniel Mark; James Min; Patrick O'Gara; Geoffrey D Rubin Journal: J Cardiovasc Comput Tomogr Date: 2010-11-23
Authors: Kavitha M Chinnaiyan; Patricia Peyser; Tauqir Goraya; Karthikeyan Ananthasubramaniam; Michael Gallagher; Ann Depetris; Judith A Boura; Ella Kazerooni; Chad Poopat; Mouaz Al-Mallah; Souheil Saba; Smita Patel; Steven Girard; Thomas Song; David Share; Gilbert Raff Journal: J Am Coll Cardiol Date: 2012-08-08 Impact factor: 24.094