| Literature DB >> 28505086 |
Yiyan Song1, Zhihui Xu2, Xinyu Yu3, Xueyan Shi4, Huijun Jiang5, Xiaoming Li6, Yan Kong7, Qin Xu8, Jin Chen9,10.
Abstract
BiOCl-SiO₂ KIT-6 composite materials with raspberry-like structures are facilely prepared under hydrothermal conditions. The mesoporous siliceous support of SiO₂ KIT-6-incorporated BiOCl with enlarged yet refined surface morphology characterized by physiochemical methods exhibits an improved electrochemical performance. A sensitive electrochemical detection method of cadmium concentration using square wave anodic stripping voltammetry was developed based on BiOCl-SiO₂ KIT-6 composite-modified glassy carbon electrodes, which displayed wide linear ranges of 0.5 to 10 μg/L and 10 to 300 μg/L and a detection limit of 65 ng/L. The sensitive, versatile and eco-friendly sensor was successfully applied for the determination of cadmium-spiked human blood samples.Entities:
Keywords: ICP-MS; anodic stripping voltammetry; bismuth; blood cadmium; mesoporous materials
Mesh:
Substances:
Year: 2017 PMID: 28505086 PMCID: PMC6154545 DOI: 10.3390/molecules22050797
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1SEM images of (A) BiOCl and (B) BiOCl-SiO2 KIT-6 composite, with insets showing magnified views of the surfaces.
Figure 2TEM images of the pure (A) SiO2 KIT-6, (B) BiOCl, (C) BiOCl-SiO2 KIT-6, and (D) energy-dispersive X-ray (EDX) spectrum of BiOCl- SiO2 KIT-6 composite.
Figure 3XRD pattern of BiOCl-SiO2 KIT-6 composite.
Figure 4(A) Square wave anodic stripping voltammetric (SWASV) responses of peak current on the concentration of Cd2+ using BiOCl-SiO2 KIT-6/GCE in 0.1 M acetate buffer solution (pH 4.5) at optimal conditions. (B) Calibration curves of Cd2+ over a concentration range of 0.5 to 300 μg/L. (C) Cyclic voltammetric (CV) analysis of BiOCl-SiO2 KIT-6/GCE in acetate buffer (0.1 M, pH 4.5). (D) The determination result of blood cadmium concentration by anodic stripping voltammetry (ASV) using BiOCl-SiO2 KIT-6/GCE in comparison with ICP-MS assay.
Analytical parameters for ASV in the determination of Cd2+ obtained by BiOCl-SiO2 KIT-6/GCE.
| Electrode | pH | Deposition Potential (V) | Deposition Time (s) | Dropping Volume of Composite (μL) |
|---|---|---|---|---|
| BiOCl-SiO2 KIT-6/GCE | 4.5 | −1.3 | 120 | 10 |
Comparison of the analytical performance of Bi film-modified electrodes for the measurement of Cd (II) by ASV.
| Electrode | Linear Range (μg/L) | Detection Limit (μg/L) | Reference |
|---|---|---|---|
| Bi/SPME | NR | 1.3 | [ |
| Bi/MWCNT-EBP-NA/GCE | 1.0–50.0 | 0.06 | [ |
| BiOCl/MWCNT/GCE | 5–50 | 1.2 | [ |
| BiFE | NR | 0.2 | [ |
| BiOPE | 20–100 | 1.5 | [ |
| BiOCl-SiO2 KIT-6/GCE | 0.5–300 | 0.065 | This work |
Bi/SPME: bismuth-coated screen-printed microband electrode, Bi/MWCNT-EBP-NA/GCE: Bi/multi-walled carbon nanotube-emeraldine base polyaniline-Nafion composite-modified glassy carbon electrode, BiOCl/MWCNT/GCE: BiOCl particle-multiwalled carbon nanotube composite-modified glassy carbon electrode, BiFE: bismuth film electrode, BiOPE: bismuth oxide printed on electrode, NR: not reported.