Literature DB >> 17949057

Antimony film electrode for electrochemical stripping analysis.

Samo B Hocevar1, Ivan Svancara, Bozidar Ogorevc, Karel Vytras.   

Abstract

In this work, an antimony film electrode (SbFE) is reported for the first time as a possible alternative for electrochemical stripping analysis of trace heavy metals. The SbFE was prepared in situ on a glassy carbon substrate electrode and employed in combination with either anodic stripping voltammetry or stripping chronopotentiometry in nondeaerated solutions of 0.01 M hydrochloric acid (pH 2). Several key operational parameters influencing the electroanalytical response of SbFE were examined and optimized, such as deposition potential, deposition time, and composition of the measurement solution. The SbFE exhibited well-defined and separated stripping signals for both model metal ions, Cd(II) and Pb(II), surrounded with low background contribution and a relatively large negative potential range. The electrode revealed good linear behavior in the examined concentration range from 20 to 140 microg L-1 for both test metal ions, with a limit of detection (3sigma) of 0.7 microg L-1 for Cd(II) and 0.9 microg L-1 for Pb(II) obtained after a 120 s deposition step, and good reproducibility, with a relative standard deviation (RSD) of +/-3.6% for Cd(II) and +/-6.2% for Pb(II) (60 microg L-1, n = 12). When comparing the SbFE with the commonly used mercury film electrode and recently introduced bismuth film electrode, the newly proposed electrode offers a remarkable performance in more acidic solutions (pH < or = 2), which can be advantageous in electrochemical analysis of trace heavy metals, hence contributing to the wider applicability of electrochemical stripping techniques in connection with "mercury-free" electrodes.

Entities:  

Year:  2007        PMID: 17949057     DOI: 10.1021/ac070478m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

2.  The Use of a Solid Bismuth Microelectrode for Vanadium Quantification by Adsorptive Stripping Voltammetry in Environmental Water Samples.

Authors:  Malgorzata Grabarczyk; Marzena Adamczyk; Edyta Wlazlowska
Journal:  Molecules       Date:  2022-03-27       Impact factor: 4.411

Review 3.  Modified electrodes used for electrochemical detection of metal ions in environmental analysis.

Authors:  Gregory March; Tuan Dung Nguyen; Benoit Piro
Journal:  Biosensors (Basel)       Date:  2015-04-29

4.  Quantification of lead in cooking utensils and vegetables using square wave anodic stripping voltammetry.

Authors:  Belete Tesfaw; Solomon Mehretie; Shimelis Admassie
Journal:  Heliyon       Date:  2018-02-01

Review 5.  Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

Authors:  Anastasios Economou
Journal:  Sensors (Basel)       Date:  2018-03-29       Impact factor: 3.576

6.  Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination.

Authors:  Matjaž Finšgar; David Majer; Uroš Maver; Tina Maver
Journal:  Sensors (Basel)       Date:  2018-11-15       Impact factor: 3.576

7.  Raspberry-Like Bismuth Oxychloride on Mesoporous Siliceous Support for Sensitive Electrochemical Stripping Analysis of Cadmium.

Authors:  Yiyan Song; Zhihui Xu; Xinyu Yu; Xueyan Shi; Huijun Jiang; Xiaoming Li; Yan Kong; Qin Xu; Jin Chen
Journal:  Molecules       Date:  2017-05-13       Impact factor: 4.411

8.  Disposable Injection Molded Conductive Electrodes Modified with Antimony Film for the Electrochemical Determination of Trace Pb(II) and Cd(II).

Authors:  Savvina Christidi; Alexia Chrysostomou; Anastasios Economou; Christos Kokkinos; Peter R Fielden; Sara J Baldock; Nicholas J Goddard
Journal:  Sensors (Basel)       Date:  2019-11-05       Impact factor: 3.576

Review 9.  Thin Film Electrodes for Anodic Stripping Voltammetry: A Mini-Review.

Authors:  Bryan R Wygant; Timothy N Lambert
Journal:  Front Chem       Date:  2022-02-02       Impact factor: 5.221

10.  Electrode Modified by Reduced Graphene Oxide for Monitoring of Total Thallium in Grain Products.

Authors:  Bozena Karbowska; Tomasz Rębiś; Grzegorz Milczarek
Journal:  Int J Environ Res Public Health       Date:  2018-04-01       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.