| Literature DB >> 28501905 |
Michael Anderson1, Qin Zheng1, Xinzhong Dong2,3.
Abstract
Due to the complex circuitry and plethora of cell types involved in somatosensation, it is becoming increasingly important to be able to observe cellular activity at the population level. In addition, since cells rely on an intricate variety of extracellular factors, it is important to strive to maintain the physiological environment. Many electrophysiological techniques require the implementation of artificially-produced physiological environments and it can be difficult to assess the activity of many cells simultaneously. Moreover, imaging Ca2+ transients using Ca2+-sensitive dyes often requires in vitro preparations or in vivo injections, which can lead to variable expression levels. With the development of more sensitive genetically-encoded Ca2+ indicators (GECIs) it is now possible to observe changes in Ca2+ transients in large populations of cells at the same time. Recently, groups have used a GECI called GCaMP to address fundamental questions in somatosensation. Researchers can now induce GCaMP expression in the mouse genome using viral or gene knock-in approaches and observe the activity of populations of cells in the pain pathway such as dorsal root ganglia (DRG), spinal neurons, or glia. This approach can be used in vivo and thus maintains the organism's biological integrity. The implementation of GCaMP imaging has led to many advances in our understanding of somatosensation. Here, we review the current findings in pain research using GCaMP imaging as well as discussing potential methodological considerations.Entities:
Keywords: DRG; GCaMP imaging; Neural circuit; Pain pathways; Spinal cord
Mesh:
Substances:
Year: 2017 PMID: 28501905 PMCID: PMC5799123 DOI: 10.1007/s12264-017-0139-9
Source DB: PubMed Journal: Neurosci Bull ISSN: 1995-8218 Impact factor: 5.203
Fig. 1Representative in vivo DRG images from a Pirt-cre;Rosa26-flox-stop-flox-GCaMP6s heterozygous mouse. A Background GCaMP fluorescence in the absence of stimulation to the hind paw. Arrows indicate spontaneously firing neurons. B ROIs manually traced for neurons from panels C and D responding to noxious heat (red), brush (green), or both heat and brush (yellow). C Representative Ca2+ transient in response to placing the ipsilateral hindpaw in a beaker of 48 °C water. Cell diameters of responding neurons range from 11.3 to 33.1 μm. Mean cell diameter = 21.0 ± 0.3 μm. D Representative Ca2+ response to applying gentle brushing to the dorsal aspect of the ipsilateral hind paw. Cell diameters of responding neurons range from 18.7 to 44.6 μm. Mean cell diameter = 29.8 ± 1.1 μm.
Advantages and disadvantages of in vivo GCaMP imaging.
| Advantages | Disadvantages |
|---|---|
| Simultaneous visualization of Ca2+ transients in large populations of cells | Can be difficult to observe targets in highly scattering tissue |
| Excellent spatial resolution | Limited temporal resolution |
| Improved preservation of physiological condition | Not a direct measurement of action potential firing |
| Does not require application or injection of Ca2+-sensitive dyes | Can be susceptible to effects of Ca2+-buffering |
| Uses minimally-invasive properties of light | Cannot measure neurophysiological characteristics such as action potential number, frequency, duration |
| Maintenance of somatotopic organization | Level of fluorescence can be affected by variable GCaMP expression levels |
| Can be inserted into mouse genome, allowing for easy and repeatable expression between generations | Susceptible to effects of phototoxicity |
| Can be combined with other fluorophores for multichannel imaging |