Literature DB >> 28492433

COMBINED PARS PLANA VITRECTOMY AND SCLERAL FIXATION OF AN INTRAOCULAR LENS USING GORE-TEX SUTURE: One-Year Outcomes.

M Ali Khan1,2, Wasim A Samara1, Adam T Gerstenblith3, Allen Chiang1, Sonia Mehta1, Sunir J Garg1, Jason Hsu1, Omesh P Gupta1.   

Abstract

PURPOSE: To report the 1-year clinical outcomes of combined pars plana vitrectomy and ab externo scleral fixation of an intraocular lens using Gore-Tex suture.
METHODS: Retrospective, interventional case series. Outcome measures were change in visual acuity and occurrence of intraoperative and postoperative complications with minimum follow-up of 1 year.
RESULTS: Eighty-four eyes of 83 patients were identified. The mean best available visual acuity improved from 20/782 preoperatively to 20/65 postoperatively (P < 0.001). The mean follow-up was 598 ± 183 days (median 533 days, range 365-1,323 days). There were no intraoperative complications noted. A Bausch &amp; Lomb Akreos AO60 intraocular lens was implanted in 77 eyes and an Alcon CZ70BD in 7 eyes. Postoperative complications included transient vitreous hemorrhage in six eyes (7.1%), cystoid macular edema in four eyes (4.8%), ocular hypertension in three eyes (3.6%), hyphema in two eyes (2.4%), and transient corneal edema in two eyes (2.4%). There were no cases of postoperative endophthalmitis, suture erosion/breakage, hypotony, retinal detachment, suprachoroidal hemorrhage, choroidal detachment, uveitis-glaucoma-hyphema syndrome, or persistent postoperative inflammation during the follow-up period.
CONCLUSION: Combined pars plana vitrectomy and ab externo scleral fixation of an intraocular lens with Gore-Tex suture was well tolerated at a minimum of 1-year follow-up. No suture-related complications were encountered.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 28492433     DOI: 10.1097/IAE.0000000000001692

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  12 in total

1.  Scleral Fixation of Intraocular Lenses with Gore-Tex Suture: Refractive Outcomes and Comparison of Lens Power Formulas.

Authors:  Benjamin W Botsford; Andrew M Williams; Ian P Conner; Joseph N Martel; Andrew W Eller
Journal:  Ophthalmol Retina       Date:  2019-02-19

2.  Short-term outcomes of a modified technique for small-incision scleral-fixated intraocular lens implantation using Gore-Tex sutures.

Authors:  Ching-Wen Huang; Chia-Ying Tsai; Tso-Ting Lai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-04-29       Impact factor: 3.117

3.  Refractive outcomes of scleral-sutured posterior chamber intraocular lenses in post-traumatic eyes.

Authors:  Wenlong Wei; Haishuang Lin; Xuanli Zheng; Siyi Wang; Shengsheng Bai; Zhenquan Zhao
Journal:  Int Ophthalmol       Date:  2022-08-23       Impact factor: 2.029

4.  Clinical outcomes of 4-point scleral fixated 1-piece hydrophobic acrylic equiconvex intraocular lens using polytetrafluoroethylene suture.

Authors:  Nimesh A Patel; Parth Shah; Nicolas A Yannuzzi; Zubair Ansari; Jill S Zaveri; Nidhi Relhan; Basil K Williams; Ajay E Kuriyan; Christopher R Henry; Jayanth Sridhar; Luis Haddock; Jorge A Fortun; Thomas A Albini; Janet L Davis; Harry W Flynn
Journal:  Clin Ophthalmol       Date:  2018-10-23

5.  Clinical Outcomes of Secondary Scleral-Sutured Foldable Hydrophilic Acrylic Intraocular Lens Placement by Trainees: A Single-Site Analysis.

Authors:  Yesha S Shah; Angela Y Zhu; Sidra I Zafar; Daniel Sarezky; Ximin Li; T Y Alvin Liu; Mira M Sachdeva; Fasika A Woreta
Journal:  Clin Ophthalmol       Date:  2021-02-24

6.  Refractive Outcomes of Four-Point Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture.

Authors:  Nimesh A Patel; Kenneth C Fan; Nicolas A Yannuzzi; Jorge A Fortun; Luis J Haddock; Sonia H Yoo; Patrice J Persad; Elizabeth A Vanner; Sarah P Read; Basil K Williams; Jayanth Sridhar; Thomas A Albini; Harry W Flynn; Kendall Donaldson; Justin H Townsend
Journal:  Clin Ophthalmol       Date:  2020-12-21

7.  Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture: An Eye on Visual Outcomes and Postoperative Complications.

Authors:  Mariana Leuzinger-Dias; Mário Lima-Fontes; Rita Rodrigues; Cláudia Oliveira-Ferreira; Carolina Madeira; Fernando Falcão-Reis; Vítor Fernandes; Amândio Rocha-Sousa; Manuel Falcão
Journal:  J Ophthalmol       Date:  2021-12-20       Impact factor: 1.909

8.  Scleral Fixation of a Hydrophobic Acrylic Intraocular Lens with Eyelets Using 8-0 Polypropylene Suture.

Authors:  Do Wook Kim; Sung Chul Lee; Ji Hwan Lee
Journal:  Korean J Ophthalmol       Date:  2021-11-08

9.  Evaluation of the Findings of Patients Who Underwent Sutureless Flanged Transconjunctival Intrascleral Intraocular Lens Implantation with or without Pars Plana Vitrectomy.

Authors:  Elcin Suren; Mustafa Kalayci; Ersan Cetinkaya; Mehmet Fatih Kucuk; Mehmet Erkan Dogan; Doğan Durmaz; Fulya Duman; Muhammet Kazim Erol
Journal:  J Ophthalmol       Date:  2021-09-01       Impact factor: 1.909

10.  Scleral fixation using a hydrophilic four-haptic lens and polytetrafluoroethylene suture.

Authors:  Natacha B Junqueira; Leandro J Chaves; Omero Poli-Neto; Ingrid U Scott; Rodrigo Jorge
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.