| Literature DB >> 28469512 |
Naseer Ahmed1,2, Sankar Venkataraman1,2, Kate Johnson1,2, Keith Sutherland1, Shaun K Loewen3.
Abstract
INTRODUCTION: Modern radiotherapy with 4-dimensional computed tomographic (4D-CT) image acquisition for non-small cell lung cancer (NSCLC) captures respiratory-mediated tumor motion to provide more accurate target delineation. This study compares conventional 3-dimensional (3D) conformal radiotherapy (3DCRT) plans generated with standard helical free-breathing CT (FBCT) with plans generated on 4D-CT contoured volumes to determine whether target volume coverage is affected.Entities:
Keywords: 4D-CT; lung cancer; radiation
Year: 2017 PMID: 28469512 PMCID: PMC5395259 DOI: 10.1177/1179554917698461
Source DB: PubMed Journal: Clin Med Insights Oncol ISSN: 1179-5549
Patient characteristics.
| Parameter | Number | Percent |
|---|---|---|
|
| ||
| Female | 4 | 28.6 |
| Male | 10 | 71.4 |
|
| ||
| Stage I | 1 | 7.14 |
| Stage II | 1 | 7.14 |
| Stage III | 9 | 64.2 |
| Stage IV | 3 | 21.4 |
|
| ||
| <50–60 | 3 | 21.4 |
| 61–70 | 3 | 21.4 |
| 71–80 | 6 | 42.9 |
| 81–90 | 2 | 14.3 |
| Mean: 71 | Range: 53-88 | |
|
| ||
| Adenocarcinoma | 5 | 35.7 |
| Squamous cell carcinoma | 4 | 28.6 |
| Not otherwise specified | 5 | 35.2 |
|
| ||
| ⩾60 | 6 | 42.9 |
| 50–59 | 7 | 50 |
| 30–49 | 1 | 7.14 |
Total dose (Gy)/fractionation (n) schedules include 30/10, 40/16, 50/20, 55/22, and 60/30.
Comparison of treatment volumes between 2 imaging data sets.
| Parameter | No. of patients | Mean volume, cm3 | Standard deviation | Median volume, cm3 | Lower quartile | Upper quartile | |
|---|---|---|---|---|---|---|---|
| GTV_3D | 14 | 115 | 80 | 106 | 45 | 180 | .0014 |
| IGTV_4D | 14 | 152 | 84 | 160 | 86 | 219 | |
| GTVN_3D | 5 | 30 | 8 | 28 | 26 | 38 | .014 |
| ITVN_4D | 5 | 61 | 16 | 65 | 54 | 71 | |
| GTVP_3D | 14 | 105 | 82 | 77 | 31 | 179 | .0040 |
| ITVP_4D | 14 | 131 | 85 | 106 | 86 | 219 | |
| PTV_3D | 14 | 530.0 | 229.8 | 550.4 | 343.3 | 716.6 | .40 |
| PTV_4D | 14 | 499.8 | 224.0 | 544.7 | 373.2 | 661.8 |
Abbreviations: 3D, 3 dimensional; 4D, 4 dimensional; GTV, gross tumor volume; GTVN, gross tumor volume Node; GTVP, Gross tumor volume Primary; IGTV, internal gross tumor volume; ITVN, internal target volume Node; ITVP, Internal target volume Primary; PTV, planning tumor volume.
Except PTV all other volumes are significantly larger on 4D scan compared with FBCT scan.
Figure 1.Relationship between IGTV_4D and GTV_3D and individual variation in volume in each data set. The diagonal line represents perfect agreement between the 2 volumes. 3D indicates 3 dimensional; 4D, 4 dimensional; GTV, gross tumor volume; IGTV, internal gross tumor volume.
Figure 2.Minimum isodose coverage of PTV: variability was more pronounced in the 3DCRT plans superimposed on the 4D-CT data set compared with plans generated with FBCT data set indicating under-coverage due to the impact of incorporating 4D-CT gross tumor. The diagonal line represents perfect agreement. 3DCRT indicates 3-dimensional conformal radiotherapy; 4D-CT, 4-dimensional computed tomographic; FBCT, free-breathing CT; PTV, planning tumor volume.
Figure 3.Dice Similarity Coefficient for PTV_3D and PTV_4D. The mean DIC was 84%. 3D indicates 3 dimensional; 4D, 4 dimensional; PTV, planning tumor volume.