Literature DB >> 9756174

What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?

L Ekberg1, O Holmberg, L Wittgren, G Bjelkengren, T Landberg.   

Abstract

BACKGROUND: The planning target volume in radiotherapy treatment planning takes into account both movements of the clinical target volume (CTV) and set-up deviations.
MATERIALS AND METHODS: A group of patients who received radiotherapy for lung cancer were studied. In order to measure the CTV movements due to respiration and other internal organ motions, fluoroscopy was performed for 20 patients. To study the accuracy and reproducibility of patient and beam set-up, 553 electronic portal images from 20 patients were evaluated. Discrepancies between planned and actual field positions were measured and the systematic and random errors were identified. The combined effect of these geometrical variations was evaluated.
RESULTS: The average CTV movement with quiet respiration was about 2.4 mm in the medio-lateral and dorso-ventral directions. Movement in the cranio-caudal direction was on average 3.9 mm with a range of 0-12 mm. The systematic set-up errors were on average 2.0 mm in the transversal plane and 3.0 mm in the cranio-caudal direction. The random errors can be described by their standard deviations of 3.2 and 2.6 mm. In this study, the combined effect of the two parameters (CTV movement and set-up deviations) varied between 7.5 and 10.3 mm in different anatomical directions.
CONCLUSIONS: In our daily clinical routine, we use a margin of 11 mm in the transversal plane and 15 mm cranially and caudally, also taking into account other unquantified variations and uncertainties.

Entities:  

Mesh:

Year:  1998        PMID: 9756174     DOI: 10.1016/s0167-8140(98)00046-2

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  43 in total

1.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Practical approaches to four-dimensional heavy-charged-particle lung therapy.

Authors:  Shinichiro Mori; Ziji Wu; Michael R Folkert; Motoki Kumagai; Suguru Dobashi; Toshio Sugane; Masayuki Baba
Journal:  Radiol Phys Technol       Date:  2009-10-14

3.  Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis.

Authors:  Jaesung Eom; Xie George Xu; Suvranu De; Chengyu Shi
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: preliminary results.

Authors:  Luca Guerra; Sofia Meregalli; Alessandra Zorz; Rita Niespolo; Elena De Ponti; Federica Elisei; Sabrina Morzenti; Sarah Brenna; Andrea Crespi; Gianstefano Gardani; Cristina Messa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-01       Impact factor: 9.236

5.  Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters.

Authors:  Huijun Xu; J James Gordon; Jeffrey V Siebers
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 6.  MRI in medical practice and its future use in radiation oncology. Resume of XXV GOCO Congress (Montpellier) 2017.

Authors:  Xavier Druet; Estrella Acosta Sanchez; Ken Soleakhena; Anne Laprie; Jordi Sáez; Stéphanie Nougaret; Olivier Riou; Elodie Rigal; Laura Kibranian; Miguel Palacios; Ismael Membrive
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-05

7.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Dynamic MR based analysis of tumor movement in upper and mid lobe localized lung cancer.

Authors:  A Kovacs; J Hadjiev; F Lakosi; G Antal; C Vandulek; E Somogyine Ezer; P Bogner; A Horvath; I Repa
Journal:  Pathol Oncol Res       Date:  2008-09-24       Impact factor: 3.201

9.  Real-time dynamic MLC tracking for inversely optimized arc radiotherapy.

Authors:  Marianne Falk; Per Munck af Rosenschöld; Paul Keall; Herbert Cattell; Byung Chul Cho; Per Poulsen; Sergey Povzner; Amit Sawant; Jens Zimmerman; Stine Korreman
Journal:  Radiother Oncol       Date:  2010-01-19       Impact factor: 6.280

10.  Assessing four-dimensional radiotherapy planning and respiratory motion-induced dose difference based on biologically effective uniform dose.

Authors:  F-C Su; C Shi; P Mavroidis; V Goytia; R Crownover; P Rassiah-Szegedi; N Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2009-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.