Literature DB >> 28466154

Spinal cord constraints in the era of high-precision radiotherapy : Retrospective analysis of 62 spinal/paraspinal lesions with possible infringements of spinal cord constraints within a minimal volume.

Sebastian Zschaeck1, Peter Wust2, Reinhold Graf2, Waldemar Wlodarczyk2, Reinhard Schild2, Alexander Henry Thieme2, Mirko Weihrauch2, Volker Budach2, Pirus Ghadjar2.   

Abstract

OBJECTIVE: Current constraints aim to minimize the risk of radiation myelitis by the use of restrictive maximal spinal cord doses, commonly 50 Gy. However, several studies suggested that a dose-volume effect could exist. Based on these observations, we evaluated patients receiving potentially excessive doses to the spinal cord within minimal volumes. PATIENTS AND METHODS: Patients receiving radiotherapy between June 2010 and May 2015 using the NovalisTM (Varian, Palo Alto, CA, USA; Brainlab, Heimstetten, Germany) radiosurgery system were retrospectively analyzed. A total of 56 patients with 62 treated lesions that had been prescribed radiation doses close to the spinal cord potentially higher than the common 50 Gy 2‑Gy equivalent-dose (EQD2) constraint were selected for further analysis. Of these patients, 26 with 31 lesions had no history of previous irradiation, while 30 patients with 31 lesions had been previously irradiated within the treatment field.
RESULTS: According to different dose evaluation approaches (spinal canal, spinal cord contour), 16 and 10 out of 31 primary irradiated lesions infringed constraints. For the 16 lesions violating spinal canal doses, the maximum doses ranged from 50.5 to 61.9 Gy EQD2. Reirradiated lesions had an average and median cumulative dose of 70.5 and 69 Gy, respectively. Dose drop-off was steep in both groups. Median overall survival was 17 months. No radiation myelitis or radiomorphological alterations were observed during follow-up.
CONCLUSION: This study adds to the increasing body of evidence indicating that excessive spinal cord doses within a minimal volume, especially in a reirradiation setting with topographically distinct high-point doses, may be given to patients after careful evaluation of treatment- and tumor-associated risks.

Entities:  

Keywords:  Myelitis; Myelopathy; Radiosurgery; Reirradiation; Toxicity

Mesh:

Year:  2017        PMID: 28466154     DOI: 10.1007/s00066-017-1138-5

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  27 in total

1.  Effective local control of vertebral metastases by simultaneous integrated boost radiotherapy: preliminary results.

Authors:  Dorota Lubgan; Anke Ziegaus; Sabine Semrau; Ulrike Lambrecht; Sebastian Lettmaier; Rainer Fietkau
Journal:  Strahlenther Onkol       Date:  2014-11-14       Impact factor: 3.621

2.  Regional differences in radiosensitivity across the rat cervical spinal cord.

Authors:  Hendrik P Bijl; Peter van Luijk; Rob P Coppes; Jacobus M Schippers; Antonius W T Konings; Albert J van Der Kogel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

Review 3.  Dose-volume effects in the spinal cord.

Authors:  A J van der Kogel
Journal:  Radiother Oncol       Date:  1993-11       Impact factor: 6.280

4.  New approach for treatment of vertebral metastases using intensity-modulated radiotherapy.

Authors:  Toshihiko Inoue; Ryoong-Jin Oh; Hiroya Shiomi
Journal:  Strahlenther Onkol       Date:  2011-01-21       Impact factor: 3.621

Review 5.  Update of human spinal cord reirradiation tolerance based on additional data from 38 patients.

Authors:  Carsten Nieder; Anca L Grosu; Nicolaus H Andratschke; Michael Molls
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-11-02       Impact factor: 7.038

6.  Spinal cord tolerance for stereotactic body radiotherapy.

Authors:  Arjun Sahgal; Lijun Ma; Iris Gibbs; Peter C Gerszten; Sam Ryu; Scott Soltys; Vivian Weinberg; Shun Wong; Eric Chang; Jack Fowler; David A Larson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-09-16       Impact factor: 7.038

Review 7.  Radiation response of the central nervous system.

Authors:  T E Schultheiss; L E Kun; K K Ang; L C Stephens
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-03-30       Impact factor: 7.038

8.  The radiation dose-response of the human spinal cord.

Authors:  Timothy E Schultheiss
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-02-19       Impact factor: 7.038

9.  Local blood flow, oxygen tension, and oxygen consumption in the rat spinal cord. Part 1: Oxygen metabolism and neuronal function.

Authors:  N Hayashi; B A Green; M Gonzalez-Carvajal; J Mora; R P Veraa
Journal:  J Neurosurg       Date:  1983-04       Impact factor: 5.115

10.  Unexpected changes of rat cervical spinal cord tolerance caused by inhomogeneous dose distributions.

Authors:  Hendrik P Bijl; Peter van Luijk; Rob P Coppes; Jacobus M Schippers; Antonius W T Konings; Albert J van der Kogel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-09-01       Impact factor: 7.038

View more
  3 in total

1.  Repeat reirradiation of the spinal cord: multi-national expert treatment recommendations.

Authors:  Carsten Nieder; Laurie E Gaspar; Dirk De Ruysscher; Matthias Guckenberger; Minesh P Mehta; Chad G Rusthoven; Arjun Sahgal; Eleni Gkika
Journal:  Strahlenther Onkol       Date:  2018-01-23       Impact factor: 3.621

Review 2.  Cumulative dose, toxicity, and outcomes of spinal metastases re-irradiation : Systematic review on behalf of the Re-Irradiation Working Group of the Italian Association of Radiotherapy and Clinical Oncology (AIRO).

Authors:  Antonio Pontoriero; Sara Lillo; Luciana Caravatta; Fabiana Bellafiore; Silvia Longo; Elisabetta Lattanzi; Silvana Parisi; Francesco Fiorica; Mariangela Massaccesi
Journal:  Strahlenther Onkol       Date:  2021-02-26       Impact factor: 3.621

Review 3.  Re-irradiation for intra-thoracic tumours and extra-thoracic breast cancer: dose accumulation, evaluation of efficacy and toxicity based on a literature review.

Authors:  Dorota Gabrys; Roland Kulik; Agnieszka Namysł-Kaletka
Journal:  Br J Radiol       Date:  2021-12-08       Impact factor: 3.629

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.