Literature DB >> 28455465

Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis.

A K Nebergall1, M E Greene1, M B Laursen2, P T Nielsen2, H Malchau1, A Troelsen3.   

Abstract

AIMS: The objective of this five-year prospective, blinded, randomised controlled trial (RCT) was to compare femoral head penetration into a vitamin E diffused highly cross-linked polyethylene (HXLPE) liner with penetration into a medium cross-linked polyethylene control liner using radiostereometric analysis. PATIENTS AND METHODS: Patients scheduled for total hip arthroplasty (THA) were randomised to receive either the study E1 (32 patients) or the control ArComXL polyethylene (35 patients). The median age (range) of the overall cohort was 66 years (40 to 76).
RESULTS: The five-year median (interquartile range) proximal femoral head penetration into the E1 was -0.05 mm (-0.13 to -0.02) and 0.07 mm (-0.03 to 0.16) for ArComXL. At three and five years, the penetration was significantly greater in the ArComXL group compared with the E1 group (p = 0.029 and p = 0.019, respectively). All patient-reported outcomes (PROs) improved significantly from the pre-operative interval compared with those at one year, and remained favourable at five years. There were no differences between the two groups at any interval.
CONCLUSION: The five-year results showed that E1 polyethylene does not wear more than the control, ArComXL. This is the longest-term RCT comparing the wear performance and clinical outcome of vitamin E diffused HXLPE with a previous generation of medium cross-linked polyethylene. Cite this article: Bone Joint J 2017;99-B:577-84. ©2017 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Patient-reported outcome measures; Radiostereometric analysis; Randomised controlled trial; Total hip arthroplasty; Vitamin E-diffused highly cross-linked polyethylene

Mesh:

Substances:

Year:  2017        PMID: 28455465     DOI: 10.1302/0301-620X.99B5.37521

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  13 in total

Review 1.  [Total hip arthroplasty in young patients : Bearings and custom-made prostheses].

Authors:  C Benignus; M Morlock; J Beckmann
Journal:  Orthopade       Date:  2019-04       Impact factor: 1.087

2.  Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty.

Authors:  Hannah Spece; Jaclyn T Schachtner; Daniel W MacDonald; Gregg R Klein; Michael A Mont; Gwo-Chin Lee; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2019-07-18       Impact factor: 4.757

3.  Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up.

Authors:  Josef Baghdadi; Shareef Alkhateeb; Alexander Roth; Marcus Jäger
Journal:  Arch Orthop Trauma Surg       Date:  2022-04-10       Impact factor: 3.067

4.  The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up.

Authors:  T E Snijders; J J Halma; J R A Massier; S M van Gaalen; A de Gast
Journal:  HSS J       Date:  2019-04-10

5.  Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register.

Authors:  Matias Hemmilä; Inari Laaksonen; Markus Matilainen; Antti Eskelinen; Jaason Haapakoski; Ari-Pekka Puhto; Jukka Kettunen; Konsta Pamilo; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2021-02-01       Impact factor: 3.717

6.  Bearing surfaces in primary total hip arthroplasty.

Authors:  Luigi Zagra; Enrico Gallazzi
Journal:  EFORT Open Rev       Date:  2018-05-21

Review 7.  The current role of robotics in total hip arthroplasty.

Authors:  Babar Kayani; Sujith Konan; Atif Ayuob; Salamah Ayyad; Fares S Haddad
Journal:  EFORT Open Rev       Date:  2019-11-01

8.  Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.

Authors:  Kristian Kjærgaard; Ming Ding; Carsten Jensen; Charles Bragdon; Henrik Malchau; Christina M Andreasen; Ole Ovesen; Christian Hofbauer; Søren Overgaard
Journal:  Bone Joint J       Date:  2020-10       Impact factor: 5.082

9.  A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.

Authors:  Julie R A Massier; Joost H J Van Erp; Thom E Snijders; Arthur DE Gast
Journal:  Acta Orthop       Date:  2020-08-24       Impact factor: 3.717

10.  2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene.

Authors:  Joost H J van Erp; Julie R A Massier; Jelle J Halma; Thom E Snijders; Arthur de Gast
Journal:  Acta Orthop       Date:  2020-02-26       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.