Literature DB >> 28451817

Morphometric analysis of high-intensity focused ultrasound-induced lipolysis on cadaveric abdominal and thigh skin.

Sugun Lee1, Hee-Jin Kim2, Hyun Jun Park3, Hyoung Moon Kim4, So Hyun Lee4, Sung Bin Cho5,6.   

Abstract

Non-focused ultrasound and high-intensity focused ultrasound (HIFU) devices induce lipolysis by generating acoustic cavitation and coagulation necrosis in targeted tissues. We aimed to investigate the morphometric characteristics of immediate tissue reactions induced by 2 MHz, 13-mm focused HIFU via two-dimensional ultrasound images and histologic evaluation of cadaveric skin from the abdomen and thigh. Acoustic fields of a 2 MHz, 38-mm HIFU transducer were characterized by reconstruction of the fields using acoustic intensity measurement. Additionally, abdominal and thigh tissues from a fresh cadaver were treated with a HIFU device for a single, two, and three pulses at the pulse energy of 130 J/cm2 and a penetration depth of 13 mm. Acoustic intensity measurement revealed characteristic focal zones of significant thermal injury at the depth of 38 mm. In both the abdomen and thigh tissue, round to oval ablative thermal injury zones (TIZs) were visualized in subcutaneous fat layers upon treatment with a single pulse of HIFU treatment. Two to three HIFU pulses generated larger and more remarkable ablative zones throughout subcutaneous fat layers. Finally, experimental treatment in a tumescent infiltration-like setting induced larger HIFU-induced TIZs of an oval or columnar shape, compared to non-tumescent settings. Although neither acoustic intensity measurement nor cadaveric tissue exactly reflects in vivo HIFU-induced reactions in human tissue, we believe that our data will help guide further in vivo studies in investigating the therapeutic efficacy and safety of HIFU-induced lipolysis.

Entities:  

Keywords:  Ablation; Acoustic field; Cadaver; Coagulation; High-intensity focused ultrasound; Morphometric analysis

Mesh:

Year:  2017        PMID: 28451817     DOI: 10.1007/s10103-017-2220-z

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  15 in total

1.  Safety Assessment of Advanced Imaging Sequences I: Measurements.

Authors:  Jorgen Arendt Jensen; Morten Fischer Rasmussen; Michael Johannes Pihl; Simon Holbek; Carlos Armando Villagómez Hoyos; David P Bradway; Matthias Bo Stuart; Borislav Gueorguiev Tomov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-11-23       Impact factor: 2.725

2.  Measurement of high intensity focused ultrasound fields by a fiber optic probe hydrophone.

Authors:  Yufeng Zhou; Liang Zhai; Rebecca Simmons; Pei Zhong
Journal:  J Acoust Soc Am       Date:  2006-08       Impact factor: 1.840

3.  Noninvasive body contouring by focused ultrasound: safety and efficacy of the Contour I device in a multicenter, controlled, clinical study.

Authors:  Steven A Teitelbaum; John L Burns; Junichiro Kubota; Hidenori Matsuda; Morkel J Otto; Yukio Shirakabe; Yoshiro Suzuki; Spencer A Brown
Journal:  Plast Reconstr Surg       Date:  2007-09       Impact factor: 4.730

4.  Tumescent liposuction: partitioning of lidocaine at a lower dose (252 mg/l).

Authors:  Gang Wang; Weigang Cao
Journal:  Dermatology       Date:  2011-05-04       Impact factor: 5.366

5.  Efficacy of high-intensity focused ultrasonography for noninvasive body sculpting in Chinese patients.

Authors:  Samantha Y N Shek; Chi K Yeung; Johnny C Y Chan; Henry H L Chan
Journal:  Lasers Surg Med       Date:  2014-03-03       Impact factor: 4.025

Review 6.  Thermal ablation of tumours: biological mechanisms and advances in therapy.

Authors:  Katrina F Chu; Damian E Dupuy
Journal:  Nat Rev Cancer       Date:  2014-03       Impact factor: 60.716

7.  Evaluation of a novel high-intensity focused ultrasound device: preclinical studies in a porcine model.

Authors:  Mark L Jewell; Charles Desilets; Bruce R Smoller
Journal:  Aesthet Surg J       Date:  2011-05       Impact factor: 4.283

8.  The use of focused ultrasound for non-invasive body contouring in Asians.

Authors:  Sam Shek; Carol Yu; C K Yeung; Taro Kono; Henry H Chan
Journal:  Lasers Surg Med       Date:  2009-12       Impact factor: 4.025

9.  Simulation of non-linear acoustic field and thermal pattern of phased-array high-intensity focused ultrasound (HIFU).

Authors:  Mingjun Wang; Yufeng Zhou
Journal:  Int J Hyperthermia       Date:  2016-05-05       Impact factor: 3.914

10.  Histological and Ultrastructural Effects of Ultrasound-induced Cavitation on Human Skin Adipose Tissue.

Authors:  Daniele Bani; Alessandro Quattrini Li; Giancarlo Freschi; Giulia Lo Russo
Journal:  Plast Reconstr Surg Glob Open       Date:  2013-10-07
View more
  2 in total

1.  Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring.

Authors:  Bishara S Atiyeh; Fadl Chahine
Journal:  Aesthetic Plast Surg       Date:  2020-07-23       Impact factor: 2.326

2.  Case report: Traumatic carotid artery dissection after 7D High-Intensity Macro- and Micro-Focused Ultrasound treatment for skin laxity of the neck.

Authors:  Fenghe Du; Jiang Shao; Zhichao Lai; Kang Li; Chaonan Wang; Bao Liu
Journal:  Front Cardiovasc Med       Date:  2022-08-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.