PURPOSE: HIFU becomes an effective and non-invasive modality of solid tumour/cancer ablation. Simulation of the non-linear acoustic wave propagation using a phased-array transducer in multiple layered media using different focusing strategies and the consequent lesion formation are essential in HIFU planning in order to enhance the efficacy and efficiency of treatment.
MATERIALS AND METHODS: An angular spectrum approach with marching fractional steps was applied in the wave propagation from phased-array HIFU transducer, and diffraction, attenuation, and non-linearity effects were accounted for by a second-order operator splitting scheme. The simulated distributions of the first three harmonics along and transverse to the transducer axis were compared to the hydrophone measurements. The bioheat equation was used to simulate the subsequent temperature elevation using the deposited acoustic energy, and lesion formation was determined by the thermal dose.
RESULTS: Better agreement was found between the measured harmonics distribution and simulation using the proposed algorithm than the Khokhlov-Zabozotskaya-Kuznetsov equation. Variable focusing of the phased-array transducer (geometric focusing, transverse shifting and the generation of multiple foci) can be simulated successfully. The shifting and splitting of focus was found to result in significantly less temperature elevation at the focus and the subsequently, the smaller lesion size, but the larger grating lobe grating lobe in the pre-focal region.
CONCLUSIONS: The proposed algorithm could simulate the non-linear wave propagation from the source with arbitrary shape and distribution of excitation through multiple tissue layers in high computation accuracy. The performance of phased-array HIFU can be optimised in the treatment planning.

Entities:  

Keywords:  Angular spectrum approach; high intensity focused ultrasound (HIFU); non-linear acoustic field; second-order operator splitting; thermal field

Mesh:

Substances:

Year:  2016        PMID: 27145871     DOI: 10.3109/02656736.2016.1160154

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  3 in total

1.  Morphometric analysis of high-intensity focused ultrasound-induced lipolysis on cadaveric abdominal and thigh skin.

Authors:  Sugun Lee; Hee-Jin Kim; Hyun Jun Park; Hyoung Moon Kim; So Hyun Lee; Sung Bin Cho
Journal:  Lasers Med Sci       Date:  2017-04-27       Impact factor: 3.161

2.  Modeling of Microbubble-Enhanced High-Intensity Focused Ultrasound.

Authors:  Aswin Gnanaskandan; Chao-Tsung Hsiao; Georges Chahine
Journal:  Ultrasound Med Biol       Date:  2019-04-12       Impact factor: 2.998

3.  An Out-of-Plane Operated Soft Engine Driving Stretchable Zone Plate for Adjusting Focal Point of an Ultrasonic Beam.

Authors:  Guo-Hua Feng; Hong-Yu Liu
Journal:  Sensors (Basel)       Date:  2019-09-04       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.