Ultrasound Screening for Adverse Local Tissue Reaction after Hip Arthroplasty.

David J Robinson1, Steven Lee2, Paul Marks3, Michal E Schneider4.   

Abstract

Early detection of adverse local tissue reaction (ALTR) to prosthetic hip wear debris is vital to improve the success of revision surgery. Magnetic resonance imaging with metal artefact reduction sequencing (MARS MRI) is considered the modality of choice to provide cross-sectional imaging of the soft tissues. The areas adjacent to the prosthesis are, however, not readily imaged using these protocols. Ultrasound has also been recommended as an imaging modality in the follow-up of hip replacement surgery. We decided to characterise the typical ultrasound findings in a group of patients undergoing routine biennial review of arthroplastic hips with particular reference to the hip capsule, femoral neck and iliopsoas bursa and tendon adjacent to the implant. Fifty-two patients with a mean (±SD) age of 60.4 (±12) y were prospectively recruited. Twelve patients had bilateral hip prostheses, giving 64 hips for analysis. Mean (±SD) age of the prosthesis in situ was 8.2 (±3.3) y. Data were grouped on the basis of the shape of the iliofemoral ligament. The median (range) maximal anteroposterior synovial thickness was 5 (2-8) mm in the normal concave iliofemoral ligament group and 7 (4-56) mm in the abnormal straight/convex iliofemoral ligament group (p = 0.001). The anteroposterior iliopsoas tendon measurement was 5 (3-8) mm in the normal group and 5 (4-8) mm in the abnormal group (p = 0.065). ALTR development in asymptomatic well-functioning prostheses may be recognised earlier using ultrasound rather than MARS MRI by carefully assessing the shape of the iliofemoral ligament. Ultrasound findings of an abnormal straight or convex ligament may be suggestive of early ALTR and warrant streaming of patients to a more frequent surveillance program.
Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Arthroplasty; Hip replacement; Ultrasonography

Mesh:

Year:  2017        PMID: 28411966     DOI: 10.1016/j.ultrasmedbio.2017.02.001

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

1.  Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up.

Authors:  Giuseppe Sessa; Gianluca Testa; Salvatore Gioitta Iachino; Luciano Costarella; Calogero Puma Pagliarello; Margherita Ferrante; Alfina Grasso; Vito Pavone
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-22

2.  Reliability of slice-encoding for metal artefact correction (SEMAC) MRI to identify prosthesis loosening in patients with painful total hip arthroplasty - a single centre, prospective, surgical validation study.

Authors:  Tsuneari Takahashi; Siddharth Thaker; Giovanni Lettieri; Anthony Redmond; Michael R Backhouse; Martin Stone; Hemant Pandit; Philip O'Connor
Journal:  Br J Radiol       Date:  2022-02-11       Impact factor: 3.629

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.