Evaluation of the BreastSimulator software platform for breast tomography.

G Mettivier1, K Bliznakova, I Sechopoulos, J M Boone, F Di Lillo, A Sarno, R Castriconi, P Russo.   

Abstract

The aim of this work was the evaluation of the software BreastSimulator, a breast x-ray imaging simulation software, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of computed tomography (CT) scanners dedicated to the breast. Eight 3D digital breast phantoms were created with glandular fractions in the range 10%-35%. The models are characterised by different sizes and modelled realistic anatomical features. X-ray CT projections were simulated for a dedicated cone-beam CT scanner and reconstructed with the FDK algorithm. X-ray projection images were simulated for 5 mono-energetic (27, 32, 35, 43 and 51 keV) and 3 poly-energetic x-ray spectra typically employed in current CT scanners dedicated to the breast (49, 60, or 80 kVp). Clinical CT images acquired from two different clinical breast CT scanners were used for comparison purposes. The quantitative evaluation included calculation of the power-law exponent, β, from simulated and real breast tomograms, based on the power spectrum fitted with a function of the spatial frequency, f, of the form S(f)  =  α/f   β . The breast models were validated by comparison against clinical breast CT and published data. We found that the calculated β coefficients were close to that of clinical CT data from a dedicated breast CT scanner and reported data in the literature. In evaluating the software package BreastSimulator to generate breast models suitable for use with breast CT imaging, we found that the breast phantoms produced with the software tool can reproduce the anatomical structure of real breasts, as evaluated by calculating the β exponent from the power spectral analysis of simulated images. As such, this research tool might contribute considerably to the further development, testing and optimisation of breast CT imaging techniques.

Entities:  

Mesh:

Year:  2017        PMID: 28398906      PMCID: PMC5753580          DOI: 10.1088/1361-6560/aa6ca3

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Spectral analysis of full field digital mammography data.

Authors:  John J Heine; Robert P Velthuizen
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

2.  A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography.

Authors:  J M Boone; N Shah; T R Nelson
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

3.  Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality.

Authors:  Avice O'Connell; David L Conover; Yan Zhang; Posy Seifert; Wende Logan-Young; Chuen-Fu Linda Lin; Lawrence Sahler; Ruola Ning
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

4.  The myth of the 50-50 breast.

Authors:  M J Yaffe; J M Boone; N Packard; O Alonzo-Proulx; S Y Huang; C L Peressotti; A Al-Mayah; K Brock
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

5.  Comparison of power spectra for tomosynthesis projections and reconstructed images.

Authors:  Emma Engstrom; Ingrid Reiser; Robert Nishikawa
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

Review 6.  Dedicated breast computed tomography: Basic aspects.

Authors:  Antonio Sarno; Giovanni Mettivier; Paolo Russo
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

7.  Cone-beam micro computed tomography dedicated to the breast.

Authors:  Antonio Sarno; Giovanni Mettivier; Francesca Di Lillo; Mario Cesarelli; Paolo Bifulco; Paolo Russo
Journal:  Med Eng Phys       Date:  2016-10-07       Impact factor: 2.242

8.  Imaging performance of phase-contrast breast computed tomography with synchrotron radiation and a CdTe photon-counting detector.

Authors:  A Sarno; G Mettivier; B Golosio; P Oliva; G Spandre; F Di Lillo; C Fedon; R Longo; P Russo
Journal:  Phys Med       Date:  2016-05-06       Impact factor: 2.685

9.  Human observer detection experiments with mammograms and power-law noise.

Authors:  A E Burgess; F L Jacobson; P F Judy
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

10.  Association between power law coefficients of the anatomical noise power spectrum and lesion detectability in breast imaging modalities.

Authors:  Lin Chen; Craig K Abbey; John M Boone
Journal:  Phys Med Biol       Date:  2013-02-19       Impact factor: 3.609

View more
  2 in total

Review 1.  Dedicated Breast Gamma Camera Imaging and Breast PET: Current Status and Future Directions.

Authors:  Deepa Narayanan; Wendie A Berg
Journal:  PET Clin       Date:  2018-07

2.  Patient-derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis.

Authors:  Marco Caballo; Carolina Rabin; Christian Fedon; Alejandro Rodríguez-Ruiz; Oliver Diaz; John M Boone; David R Dance; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2022-06-08       Impact factor: 4.506

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.