Valve mediated hemodynamics and their association with distal ascending aortic diameter in bicuspid aortic valve subjects.

Vrishank Raghav1,2, Alex J Barker3, Daniel Mangiameli1, Lucia Mirabella1, Michael Markl3, Ajit P Yoganathan1.   

Abstract

PURPOSE: Valve mediated hemodynamics have been postulated to contribute to pathology of the ascending aorta (AAo). The objective of this study is to assess the association of aortic valve morphology and hemodynamics with downstream AAo size in subjects with bicuspid aortic valve (BAV) disease.
MATERIALS AND METHODS: Four-dimensional flow MRI at 1.5 or 3 Tesla was used to evaluate the hemodynamics in the proximal AAo of 52 subjects: size-matched controls with tricuspid aortic valves (n = 24, mid ascending aorta [MAA] diameter = 38.0 ± 4.9 mm) and BAV patients with aortic dilatation (n = 14 right and left coronary leaflet fusion [RL]-BAV, MAA diameter = 38.1 ± 5.3 mm; n = 14 right and noncoronary leaflet fusion [RN]-BAV, MAA diameter = 36.5 ± 6.6 mm). A validated semi-automated technique was used to evaluate hemodynamic metrics (flow angle, flow displacement, and jet quadrant) and valve morphology (orifice circularity) for all subjects. Regression analysis of these metrics to AAo diameter was performed.
RESULTS: RN-BAV subjects displayed a stronger correlation between hemodynamic metrics in the proximal AAo with diameter in the distal AAo compared with size-matched tricuspid aortic valve (TAV) controls and RL-BAV subjects. The distal AAo diameter was found to be strongly correlated to the upstream flow displacement (R2adjusted = 0.75) and flow angle (R2adjusted = 0.66) measured at the sino-tubular junction (STJ). Orifice circularity was also strongly correlated (R2adjusted = 0.53) to the distal AAo diameter in RN-BAV subjects. For TAV controls and RL-BAV subjects, correlations were weaker (R2adjusted < 0.2).
CONCLUSION: Hemodynamics in the STJ were strongly correlated to the distal AAo diameter for the RN-BAV subjects. Hemodynamic metrics were more strongly correlated to the downstream aortic size when compared with valve morphology metrics. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:246-254.
© 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  4D flow MRI; aortic diseases; bicuspid aortic valve; flow displacement; hemodynamics; valve fusion pattern

Mesh:

Year:  2017        PMID: 28390180      PMCID: PMC5632568          DOI: 10.1002/jmri.25719

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

Review 1.  Clinical significance of the bicuspid aortic valve.

Authors:  C Ward
Journal:  Heart       Date:  2000-01       Impact factor: 5.994

2.  Four-dimensional flow magnetic resonance imaging-based characterization of aortic morphometry and haemodynamics: impact of age, aortic diameter, and valve morphology.

Authors:  Julio Garcia; Alex J Barker; Ian Murphy; Kelly Jarvis; Susanne Schnell; Jeremy D Collins; James C Carr; S Chris Malaisrie; Michael Markl
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-09-15       Impact factor: 6.875

Review 3.  Ascending aortic dilatation associated with bicuspid aortic valve: pathophysiology, molecular biology, and clinical implications.

Authors:  Thomas M Tadros; Michael D Klein; Oz M Shapira
Journal:  Circulation       Date:  2009-02-17       Impact factor: 29.690

4.  The bicuspid aortic valve aortopathy mystery continues: Are we that mediocre?

Authors:  Hector I Michelena
Journal:  Trends Cardiovasc Med       Date:  2015-01-02       Impact factor: 6.677

Review 5.  The natural history of guidelines: the case of aortopathy related to bicuspid aortic valves.

Authors:  Ashutosh A Hardikar; Thomas H Marwick
Journal:  Int J Cardiol       Date:  2015-06-25       Impact factor: 4.164

6.  Functional Aortic Root Parameters and Expression of Aortopathy in Bicuspid Versus Tricuspid Aortic Valve Stenosis.

Authors:  Evaldas Girdauskas; Mina Rouman; Kushtrim Disha; Beatrix Fey; Georg Dubslaff; Bernhard Theis; Iver Petersen; Matthias Gutberlet; Michael A Borger; Thomas Kuntze
Journal:  J Am Coll Cardiol       Date:  2016-04-19       Impact factor: 24.094

7.  Cardiac magnetic resonance imaging is more diagnostic than 2-dimensional echocardiography in determining the presence of bicuspid aortic valve.

Authors:  S Chris Malaisrie; James Carr; Issam Mikati; Vera Rigolin; Byron K Yip; Brittany Lapin; Patrick M McCarthy
Journal:  J Thorac Cardiovasc Surg       Date:  2011-12-10       Impact factor: 5.209

8.  Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns.

Authors:  Michael D Hope; Thomas A Hope; Alison K Meadows; Karen G Ordovas; Thomas H Urbania; Marcus T Alley; Charles B Higgins
Journal:  Radiology       Date:  2010-04       Impact factor: 11.105

9.  Bicuspid aortic valve disease: a comprehensive review.

Authors:  Ify Mordi; Nikolaos Tzemos
Journal:  Cardiol Res Pract       Date:  2012-05-28       Impact factor: 1.866

10.  Aortic dilation in bicuspid aortic valve disease: flow pattern is a major contributor and differs with valve fusion type.

Authors:  Malenka M Bissell; Aaron T Hess; Luca Biasiolli; Steffan J Glaze; Margaret Loudon; Alex Pitcher; Anne Davis; Bernard Prendergast; Michael Markl; Alex J Barker; Stefan Neubauer; Saul G Myerson
Journal:  Circ Cardiovasc Imaging       Date:  2013-06-14       Impact factor: 7.792

View more
  6 in total

1.  Analysis of Inlet Velocity Profiles in Numerical Assessment of Fontan Hemodynamics.

Authors:  Zhenglun Alan Wei; Connor Huddleston; Phillip M Trusty; Shelly Singh-Gryzbon; Mark A Fogel; Alessandro Veneziani; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2019-06-24       Impact factor: 3.934

2.  Clinical-pathological correlations of BAV and the attendant thoracic aortopathies. Part 1: Pluridisciplinary perspective on their hemodynamics and morphomechanics.

Authors:  Ares Pasipoularides
Journal:  J Mol Cell Cardiol       Date:  2019-05-28       Impact factor: 5.000

3.  Association between flow skewness and aortic dilatation in patients with aortic stenosis.

Authors:  Hojin Ha; Hyun Jung Koo; June Goo Lee; Guk Bae Kim; Jihoon Kweon; Sang Joon Lee; Joon Won Kang; Tae Hwan Lim; Dae Hee Kim; Jong Min Song; Duk Hyun Kang; Jae Kwan Song; Young Hak Kim; Namkug Kim; Dong Hyun Yang
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-16       Impact factor: 2.357

Review 4.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

Review 5.  Pathogenic Mechanisms of Bicuspid Aortic Valve Aortopathy.

Authors:  Noor M Yassine; Jasmine T Shahram; Simon C Body
Journal:  Front Physiol       Date:  2017-09-25       Impact factor: 4.566

Review 6.  Clinical implications of the biomechanics of bicuspid aortic valve and bicuspid aortopathy.

Authors:  Ali Fatehi Hassanabad; Melissa A King; Elena Di Martino; Paul W M Fedak; Julio Garcia
Journal:  Front Cardiovasc Med       Date:  2022-08-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.