| Literature DB >> 28382294 |
Nadiar Mussin1, Marco Sumo2, Kwang-Woong Lee1, YoungRok Choi3, Jin Yong Choi1, Sung-Woo Ahn1, Kyung Chul Yoon1, Hyo-Sin Kim1, Suk Kyun Hong1, Nam-Joon Yi1, Kyung-Suk Suh1.
Abstract
PURPOSE: Liver volumetry is a vital component in living donor liver transplantation to determine an adequate graft volume that meets the metabolic demands of the recipient and at the same time ensures donor safety. Most institutions use preoperative contrast-enhanced CT image-based software programs to estimate graft volume. The objective of this study was to evaluate the accuracy of 2 liver volumetry programs (Rapidia vs. Dr. Liver) in preoperative right liver graft estimation compared with real graft weight.Entities:
Keywords: Donor selection; Living donors; Organ size
Year: 2017 PMID: 28382294 PMCID: PMC5378562 DOI: 10.4174/astr.2017.92.4.214
Source DB: PubMed Journal: Ann Surg Treat Res ISSN: 2288-6575 Impact factor: 1.859
Descriptive summary of characteristics of available liver volumetry softwares
Baseline characteristics of living donors
Values are presented as number, mean ± standard deviation, or number (%).
GRWR, graft-to-recipient weight ratio.
a)Graft volume by volumetry/recipient body weight. b)Graft weight measured intraoperatively/recipient body weight.
Rapidia software (Infinitt Co., Ltd., Seoul, Korea); Dr. Liver software (Virtual Liver Surgery Planning System, Humanopia Co. Ltd, Pohang, Korea).
Grading of difference between estimated graft volume and real graft weight
Values are presented as number (%).
Rapidia software (Infinitt Co., Ltd., Seoul, Korea); Dr. Liver software (Virtual Liver Surgery Planning System, Humanopia Co. Ltd, Pohang, Korea).
Fig. 1Correlation between preoperative and real graft weight using the 2 programs. Scatterplot diagrams show a positive linear correlation for preoperative volume (Volumetry) and real graft weight (Graft Weight) determinations in Rapidia (A) and Dr. Liver (B). The correlation coefficient was better in the Dr. Liver group (R2 = 0.688 vs. R2 = 0.719). Rapidia software (Infinitt Co., Ltd., Seoul, Korea); Dr. Liver software (Virtual Liver Surgery Planning System, Humanopia Co. Ltd, Pohang, Korea).
Fig. 2Difference in liver extraction process between Rapidia and Dr. Liver for normal and fatty liver. (A, B) Parenchyma of normal and fatty liver at same threshold range 83–150 (Rapidia). (C) Fatty liver at an adjusted threshold range 50–1,000 (Rapidia) to include most of parenchyma. (D, E) Parenchyma of normal and fatty liver (Dr. Liver) not dependent on attenuation/thresholding adjustments. Rapidia software (Infinitt Co., Ltd., Seoul, Korea); Dr. Liver software (Virtual Liver Surgery Planning System, Humanopia Co. Ltd, Pohang, Korea).