Literature DB >> 28372729

Development of a thermostabilised triplex LAMP assay with dry-reagent four target lateral flow dipstick for detection of Entamoeba histolytica and non-pathogenic Entamoeba spp.

Phiaw Chong Foo1, Yean Yean Chan2, Maizan Mohamed3, Weng Kin Wong4, A B Nurul Najian5, Boon Huat Lim6.   

Abstract

This study highlighted the development of a four target nitrocellulose-based nucleic acid lateral flow immunoassay biosensor in a dry-reagent strip format for interpretation of double-labelled double-stranded amplicons from thermostabilised triplex loop-mediated isothermal amplification assay. The DNA biosensor contained two test lines which captured biotin and texas red labelled amplicons; a LAMP internal amplification control line that captured digoxigenin labelled amplicon; and a chromatography control line that validated the functionality of the conjugated gold nanoparticles and membrane. The red lines on detection pad were generated when the gold nanoparticles conjugated antibody bound to the fluorescein labelled amplicons, and the capture agents bound to their specific hapten on the other 5' end of the double-stranded amplicon. The applicability of this DNA biosensor was demonstrated using amoebiasis-causing Entamoeba histolytica simultaneously with the non-pathogenic but morphologically identical Entamoeba dispar and Entamoeba moshkovskii. The biosensor detection limit was 10 E. histolytica trophozoites, and revealed 100% specificity when it was evaluated against 3 medically important Entamoeba species and 75 other pathogenic microorganisms. Heat stability test showed that the biosensor was stable for at least 181 days at ambient temperature. This ready-to-use and cold-chain-free biosensor facilitated the post-LAMP analysis based on visualisation of lines on strip instead of observation of amplicon patterns in agarose gel.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DNA lateral flow biosensor; Entamoeba histolytica; Isothermal amplification; Multiplex LAMP; Thermostabilization

Mesh:

Substances:

Year:  2017        PMID: 28372729     DOI: 10.1016/j.aca.2017.02.019

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

1.  Development of Loop-Mediated Isothermal Amplification-Based Lateral Flow Device Method for the Detection of Malaria.

Authors:  Prudhvi Chand Mallepaddi; Meng-Yee Lai; Sudhakar Podha; Choo-Huck Ooi; Jonathan Wee-Kent Liew; Rathnagiri Polavarapu; Yee-Ling Lau
Journal:  Am J Trop Med Hyg       Date:  2018-06-21       Impact factor: 2.345

2.  Recent Advances in Design of Fluorescence-Based Assays for High-Throughput Screening.

Authors:  Xiaoni Fang; Yongzan Zheng; Yaokai Duan; Yang Liu; Wenwan Zhong
Journal:  Anal Chem       Date:  2018-12-10       Impact factor: 6.986

Review 3.  Update on laboratory diagnosis of amoebiasis.

Authors:  Syazwan Saidin; Nurulhasanah Othman; Rahmah Noordin
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2018-09-25       Impact factor: 3.267

4.  Loop-mediated isothermal amplification (LAMP) reaction as viable PCR substitute for diagnostic applications: a comparative analysis study of LAMP, conventional PCR, nested PCR (nPCR) and real-time PCR (qPCR) based on Entamoeba histolytica DNA derived from faecal sample.

Authors:  Phiaw Chong Foo; A B Nurul Najian; Nuramin A Muhamad; Mariana Ahamad; Maizan Mohamed; Chan Yean Yean; Boon Huat Lim
Journal:  BMC Biotechnol       Date:  2020-06-22       Impact factor: 2.563

Review 5.  Mini review: Recent progress in RT-LAMP enabled COVID-19 detection.

Authors:  Dorian Thompson; Yu Lei
Journal:  Sens Actuators Rep       Date:  2020-08-15

6.  Point of care colourimetric and lateral flow LAMP assay for the detection of Haemonchus contortus in ruminant faecal samples.

Authors:  Rojesh Khangembam; Mariann Tóth; Nóra Vass; Marián Várady; Levente Czeglédi; Róbert Farkas; Alistair Antonopoulos
Journal:  Parasite       Date:  2021-12-15       Impact factor: 3.000

7.  Multicenter international assessment of a SARS-CoV-2 RT-LAMP test for point of care clinical application.

Authors:  Suying Lu; David Duplat; Paula Benitez-Bolivar; Cielo León; Stephany D Villota; Eliana Veloz-Villavicencio; Valentina Arévalo; Katariina Jaenes; Yuxiu Guo; Seray Cicek; Lucas Robinson; Philippos Peidis; Joel D Pearson; Jim Woodgett; Tony Mazzulli; Patricio Ponce; Silvia Restrepo; John M González; Adriana Bernal; Marcela Guevara-Suarez; Keith Pardee; Varsovia E Cevallos; Camila González; Rod Bremner
Journal:  PLoS One       Date:  2022-05-11       Impact factor: 3.752

Review 8.  New Advances in Lateral Flow Immunoassay (LFI) Technology for Food Safety Detection.

Authors:  Guangxu Xing; Xuefeng Sun; Ning Li; Xuewu Li; Tiantian Wu; Fangyu Wang
Journal:  Molecules       Date:  2022-10-05       Impact factor: 4.927

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.