Literature DB >> 28366544

Evaluation of dried blood spot protocols with the Bio-Rad GS HIV Combo Ag/Ab EIA and Geenius™ HIV 1/2 Supplemental Assay.

Wei Luo1, Geoff Davis2, LiXia Li1, M Kathleen Shriver2, Joanne Mei1, Linda M Styer3, Monica M Parker3, Amanda Smith1, Gabriela Paz-Bailey1, Steve Ethridge1, Laura Wesolowski1, S Michele Owen1, Silvina Masciotra4.   

Abstract

OBJECTIVE: FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm.
METHODS: BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms.
RESULTS: BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens.
CONCLUSIONS: The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture. Published by Elsevier B.V.

Entities:  

Keywords:  DBS testing; HIV diagnostics; Surveillance

Mesh:

Substances:

Year:  2017        PMID: 28366544     DOI: 10.1016/j.jcv.2017.03.011

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  8 in total

1.  Validation of mailed via postal service dried blood spot cards on commercially available HIV testing systems.

Authors:  Tsunefusa Hayashida; Misao Takano; Kiyoto Tsuchiya; Takahiro Aoki; Hiroyuki Gatanaga; Noriyo Kaneko; Shinichi Oka
Journal:  Glob Health Med       Date:  2021-12-31

2.  HIV testing in COVID-19 pandemic and beyond in Japan.

Authors:  Shinichi Oka
Journal:  Glob Health Med       Date:  2021-12-31

3.  Stability of Human Immunodeficiency Virus Serological Markers in Samples Collected as HemaSpot and Whatman 903 Dried Blood Spots.

Authors:  Mark M Manak; Holly R Hack; Ashley L Shutt; Brook A Danboise; Linda L Jagodzinski; Sheila A Peel
Journal:  J Clin Microbiol       Date:  2018-09-25       Impact factor: 5.948

4.  Screening for Human Immunodeficiency Virus Infection by Use of a Fourth-Generation Antigen/Antibody Assay and Dried Blood Spots: In-Depth Analysis of Sensitivity and Performance Assessment in a Cross-Sectional Study.

Authors:  Karl Stefic; Jerome Guinard; Gilles Peytavin; Leïla Saboni; Cécile Sommen; Claire Sauvage; Florence Lot; Syria Laperche; Annie Velter; Francis Barin
Journal:  J Clin Microbiol       Date:  2019-12-23       Impact factor: 5.948

5.  Assessment of HIV prevalence among MSM in Tokyo using self-collected dried blood spots delivered through the postal service.

Authors:  Misao Takano; Kohta Iwahashi; Ikuo Satoh; Junko Araki; Takuya Kinami; Yuzuru Ikushima; Toshiya Fukuhara; Hiroo Obinata; Yasuyo Nakayama; Yoshimi Kikuchi; Shinichi Oka
Journal:  BMC Infect Dis       Date:  2018-12-05       Impact factor: 3.090

6.  Evaluation of the Bio-Rad Geenius HIV 1/2 Assay as Part of a Confirmatory HIV Testing Strategy for Quebec, Canada: Comparison with Western Blot and Inno-Lia Assays.

Authors:  Bouchra Serhir; Céline Desjardins; Florence Doualla-Bell; Marc Simard; Cécile Tremblay; Jean Longtin
Journal:  J Clin Microbiol       Date:  2019-05-24       Impact factor: 5.948

7.  The feasibility of modified HIV and antiretroviral drug testing using self-collected dried blood spots from men who have sex with men.

Authors:  Wei Luo; Vickie Sullivan; Pollyanna R Chavez; Sarah E Wiatrek; Maria Zlotorzynska; Amy Martin; Rebecca Rossetti; Travis Sanchez; Patrick Sullivan; Robin J MacGowan; S Michele Owen; Silvina Masciotra
Journal:  BMC Infect Dis       Date:  2021-05-05       Impact factor: 3.090

8.  Evaluation of Rapid Testing Algorithms for Venue-based Anonymous HIV Testing among Non-HIV-Positive Men Who Have Sex with Men, National HIV Behavioral Surveillance (NHBS), 2017.

Authors:  Shamaya Whitby; Amanda Smith; Rebecca Rossetti; Johanna Chapin-Bardales; Amy Martin; Cyprian Wejnert; Silvina Masciotra
Journal:  J Community Health       Date:  2020-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.