Literature DB >> 28361324

Coffee: the key to safer image-guided surgery-a granular jamming cap for non-invasive, rigid fixation of fiducial markers to the patient.

Patrick S Wellborn1, Neal P Dillon2, Paul T Russell3, Robert J Webster2.   

Abstract

PURPOSE: Accurate image guidance requires a rigid connection between tracked fiducial markers and the patient, which cannot be guaranteed by current non-invasive attachment techniques. We propose a new granular jamming approach to firmly, yet non-invasively, connect fiducials to the patient.
METHODS: Our granular jamming cap surrounds the head and conforms to the contours of the patient's skull. When a vacuum is drawn, the device solidifies in a manner conceptually like a vacuum-packed bag of ground coffee, providing a rigid structure that can firmly hold fiducial markers to the patient's skull. By using the new Polaris Krios optical tracker, we can also use more fiducials in advantageous configurations to reduce registration error.
RESULTS: We tested our new approach against a clinically used headband-based fiducial fixation device under perturbations that could reasonably be expected to occur in a real-world operating room. In bump testing, we found that the granular jamming cap reduced average TRE at the skull base from 2.29 to 0.56 mm and maximum TRE at the same point from 7.65 to 1.30 mm. Clinically significant TRE reductions were also observed in head repositioning and static force testing experiments.
CONCLUSION: The granular jamming cap concept increases the robustness and accuracy of image-guided sinus and skull base surgery by more firmly attaching fiducial markers to the patient's skull.

Entities:  

Keywords:  Endonasal surgery; Granular jamming; Image-guided surgery; Registration; Skull base surgery

Mesh:

Year:  2017        PMID: 28361324      PMCID: PMC6252059          DOI: 10.1007/s11548-017-1569-6

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  11 in total

1.  Fiducial point placement and the accuracy of point-based, rigid body registration.

Authors:  J B West; J M Fitzpatrick; S A Toms; C R Maurer; R J Maciunas
Journal:  Neurosurgery       Date:  2001-04       Impact factor: 4.654

2.  Comparison of 4 registration strategies for computer-aided maxillofacial surgery.

Authors:  Marc Christian Metzger; Amir Rafii; Bettina Holhweg-Majert; Annette M Pham; Brad Strong
Journal:  Otolaryngol Head Neck Surg       Date:  2007-07       Impact factor: 3.497

3.  A new nasopharyngeal dynamic reference frame improves accuracy in navigated skull base targets.

Authors:  Florian Kral; Matthew DiFranco; Johanna Puschban; Romed Hoermann; Herbert Riechelmann; Wolfgang Freysinger
Journal:  Surg Innov       Date:  2013-10-08       Impact factor: 2.058

4.  Predicting error in rigid-body point-based registration.

Authors:  J M Fitzpatrick; J B West; C R Maurer
Journal:  IEEE Trans Med Imaging       Date:  1998-10       Impact factor: 10.048

5.  Celebrating Soft Matter's 10th Anniversary: toward jamming by design.

Authors:  Heinrich M Jaeger
Journal:  Soft Matter       Date:  2015-01-07       Impact factor: 3.679

6.  Quantification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration.

Authors:  Christopher R Mascott; Jean-Christophe Sol; Philippe Bousquet; Jacques Lagarrigue; Yves Lazorthes; Valérie Lauwers-Cances
Journal:  Neurosurgery       Date:  2006-07       Impact factor: 4.654

7.  The role of registration in accurate surgical guidance.

Authors:  J M Fitzpatrick
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

8.  The silent loss of neuronavigation accuracy: a systematic retrospective analysis of factors influencing the mismatch of frameless stereotactic systems in cranial neurosurgery.

Authors:  Lennart Henning Stieglitz; Jens Fichtner; Robert Andres; Philippe Schucht; Ann-Kathrin Krähenbühl; Andreas Raabe; Jürgen Beck
Journal:  Neurosurgery       Date:  2013-05       Impact factor: 4.654

9.  [The use of the BrainLAB Kolibri navigation system in endoscopic paranasal sinus surgery under local anaesthesia. An analysis of 35 cases].

Authors:  K J Lorenz; S Frühwald; H Maier
Journal:  HNO       Date:  2006-11       Impact factor: 1.284

10.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01
View more
  3 in total

1.  A multi-subject accuracy study on granular jamming for non-invasive attachment of fiducial markers to patients.

Authors:  Patrick S Wellborn; Paul T Russell; Robert J Webster Iii
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-10       Impact factor: 2.924

2.  Cyclic Loading of Jammed Granular Systems.

Authors:  Piotr Bartkowski; Marta Ciemiorek; Hubert Bukowiecki; Robert Zalewski
Journal:  Materials (Basel)       Date:  2022-07-17       Impact factor: 3.748

3.  Image-guided cochlear access by non-invasive registration: a cadaveric feasibility study.

Authors:  Jiang Wang; Hongsheng Liu; Jia Ke; Lei Hu; Shaoxing Zhang; Biao Yang; Shilong Sun; Na Guo; Furong Ma
Journal:  Sci Rep       Date:  2020-10-27       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.