Literature DB >> 28361128

Design of dual multiple aperture devices for dynamical fluence field modulated CT.

Aswin John Mathews1, Steven Tilley1, Grace Gang1, Satomi Kawamoto1, Wojciech Zbijewski1, Jeffrey H Siewerdsen1, Reuven Levinson1, J Webster Stayman1.   

Abstract

A Multiple Aperture Device (MAD) is a novel x-ray beam modulator that uses binary filtration on a fine scale to spatially modulate an x-ray beam. Using two MADs in series enables a large variety of fluence profiles by shifting the MADS relative to each other. This work details the design and control of dual MADs for a specific class of desired fluence patterns. Specifically, models of MAD operation are integrated into a best fit objective followed by CMA-ES optimization. To illustrate this framework we demonstrate the design process for an abdominal phantom with the goal of uniform detected signal. Achievable fluence profiles show good agreement with target fluence profiles, and the ability to flatten projections when a phantom is scanned is demonstrated. Simulated data reconstruction using traditional tube current modulation (TCM) and MAD filtering with TCM are investigated with the dual MAD system demonstrating more uniformity in noise and illustrating the potential for dose reduction under a maximum noise level constraint.

Entities:  

Keywords:  Dynamic bow-tie filter; Fluence field modulation; Patient-specific CT; Radiation dose reduction; Region-of-interest CT; X-ray beam modulation

Year:  2016        PMID: 28361128      PMCID: PMC5370167     

Source DB:  PubMed          Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr


  7 in total

1.  Fluence field optimization for noise and dose objectives in CT.

Authors:  Steven Bartolac; Sean Graham; Jeff Siewerdsen; David Jaffray
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization.

Authors:  J H Siewerdsen; A M Waese; D J Moseley; S Richard; D A Jaffray
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

3.  The feasibility of a piecewise-linear dynamic bowtie filter.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

4.  Fluence-Field Modulated X-ray CT using Multiple Aperture Devices.

Authors:  J Webster Stayman; Aswin Mathews; Wojciech Zbijewski; Grace Gang; Jeffrey Siewerdsen; Satomi Kawamoto; Ira Blevis; Reuven Levinson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

5.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.

Authors:  Timothy P Szczykutowicz; Charles A Mistretta
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Task-Driven Tube Current Modulation and Regularization Design in Computed Tomography with Penalized-Likelihood Reconstruction.

Authors:  G J Gang; J H Siewerdsen; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-25

7.  Dynamic bowtie filter for cone-beam/multi-slice CT.

Authors:  Fenglin Liu; Qingsong Yang; Wenxiang Cong; Ge Wang
Journal:  PLoS One       Date:  2014-07-22       Impact factor: 3.240

  7 in total
  4 in total

1.  Dynamic fluence field modulation for miscentered patients in computed tomography.

Authors:  Andrew Mao; Grace J Gang; William Shyr; Reuven Levinson; Jeffrey H Siewerdsen; Satomi Kawamoto; J Webster Stayman
Journal:  J Med Imaging (Bellingham)       Date:  2018-10-24

2.  Dynamic fluence field modulation in computed tomography using multiple aperture devices.

Authors:  Grace J Gang; Andrew Mao; Wenying Wang; Jeffrey H Siewerdsen; Aswin Mathews; Satomi Kawamoto; Reuven Levinson; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-05-21       Impact factor: 3.609

3.  Dose reduction in abdominal CT: The road to submillisievert imaging.

Authors:  Alexander A Fingerle; Peter B Noël
Journal:  Eur Radiol       Date:  2018-04-10       Impact factor: 5.315

4.  Dynamic beam filtering for miscentered patients.

Authors:  Andrew Mao; William Shyr; Grace J Gang; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.