OBJECTIVE: We compared the dose distributions of postoperative plans with preoperative plans for 3D printing template-assisted radioactive seed implantations.
METHODS: A total of 14 patients with malignant tumors enrolled in the study. The dose parameters included D90, minimum peripheral dose, V100, V150, and V200. The statistical method was the paired t-test.
RESULTS: There was no significant difference in P values between the two groups for all parameters except for V100.
CONCLUSIONS: The 3D printing guide template can provide good accuracy for radioactive seed implantation.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D printing; Cancer; Dosimetry; Radioactive seeds; Template

Mesh:

Substances:

Year:  2016        PMID: 28342381     DOI: 10.1016/j.apradiso.2016.12.009

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  18 in total

1.  Accuracy and dosimetric parameters comparison of 3D-printed non-coplanar template-assisted computed tomography-guided iodine-125 seed ablative brachytherapy in pelvic lateral recurrence of gynecological carcinomas.

Authors:  Ang Qu; Ping Jiang; Shuhua Wei; Yuliang Jiang; Zhe Ji; Haitao Sun; Weiyan Li; Yuxia Shao; Jinghong Fan; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-02-18

2.  Dosimetric comparison of computed tomography-guided iodine-125 seed implantation assisted with and without three-dimensional printing non-coplanar template in locally recurrent rectal cancer: a propensity score matching study.

Authors:  Lu Wang; Hao Wang; Yuliang Jiang; Zhe Ji; Fuxin Guo; Ping Jiang; Bin Qiu; Haitao Sun; Jinghong Fan; Weiyan Li; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-02-18

3.  Therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors.

Authors:  Tao Han; Xiaodan Yang; Ying Xu; Zhendong Zheng; Ying Yan; Ning Wang
Journal:  Onco Targets Ther       Date:  2017-07-03       Impact factor: 4.147

4.  Comparative study for CT-guided 125I seed implantation assisted by 3D printing coplanar and non-coplanar template in peripheral lung cancer.

Authors:  Zhe Ji; Haitao Sun; Yuliang Jiang; Fuxin Guo; Ran Peng; Jinghong Fan; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2019-04-29

5.  Dosimetry verification of 3D-printed individual template based on CT-MRI fusion for radioactive 125I seed implantation in recurrent high-grade gliomas.

Authors:  Shifeng Liu; Hong Wang; Congxiao Wang; Hao Zhang; Wei Li; Qian Dong; Xiaokun Hu
Journal:  J Contemp Brachytherapy       Date:  2019-06-28

6.  The dosimetry evaluation of 3D printing non-coplanar template-assisted CT-guided 125I seed stereotactic ablation brachytherapy for pelvic recurrent rectal cancer after external beam radiotherapy.

Authors:  Hao Wang; Ran Peng; Xuemin Li; Yuxia Wang; Yuliang Jiang; Zhe Ji; Fuxin Guo; Suqing Tian; Haitao Sun; Jinghong Fan; Junjie Wang
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

7.  The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer.

Authors:  Weijuan Jiang; Yi Chen; Zhe Ji; Yuliang Jiang; Bin Qiu; Haitao Sun; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-05-18

8.  Dosimetric analysis of rib interference of the CTV during interstitial brachytherapy of lung tumors.

Authors:  Bo Yang; Xiaoyang Sun; Haowen Pang; Xiangxiang Shi; Tao Tang; Guangpeng Zhang; Renjin Chen; Jing Zhang; Hong Wu; Sheng Lin; Qinglian Wen; Yunwei Han; Jingbo Wu
Journal:  J Contemp Brachytherapy       Date:  2017-12-30

9.  Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors.

Authors:  Zhe Ji; Haitao Sun; Yuliang Jiang; Yi Chen; Fuxin Guo; Jinghong Fan; Junjie Wang
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

Review 10.  Dosimetry study of three-dimensional print template for 125I implantation therapy.

Authors:  Enli Chen; Yuwei Zhang; Hongtao Zhang; Chenfei Jia; Yansong Liang; Juan Wang
Journal:  Radiat Oncol       Date:  2021-06-24       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.