SSh versus TSE sequence protocol in rapid MR examination of pediatric patients with programmable drainage system.

Eva Brichtová1, J Šenkyřík2.   

Abstract

PURPOSE: A low radiation burden is essential during diagnostic procedures in pediatric patients due to their high tissue sensitivity. Using MR examination instead of the routinely used CT reduces the radiation exposure and the risk of adverse stochastic effects. Our retrospective study evaluated the possibility of using ultrafast single-shot (SSh) sequences and turbo spin echo (TSE) sequences in rapid MR brain imaging in pediatric patients with hydrocephalus and a programmable ventriculoperitoneal drainage system.
METHODS: SSh sequences seem to be suitable for examining pediatric patients due to the speed of using this technique, but significant susceptibility artifacts due to the programmable drainage valve degrade the image quality. Therefore, a rapid MR examination protocol based on TSE sequences, less sensitive to artifacts due to ferromagnetic components, has been developed. Of 61 pediatric patients who were examined using MR and the SSh sequence protocol, a group of 15 patients with hydrocephalus and a programmable drainage system also underwent TSE sequence MR imaging. The susceptibility artifact volume in both rapid MR protocols was evaluated using a semiautomatic volumetry system.
RESULTS: A statistically significant decrease in the susceptibility artifact volume has been demonstrated in TSE sequence imaging in comparison with SSh sequences. Using TSE sequences reduced the influence of artifacts from the programmable valve, and the image quality in all cases was rated as excellent. In all patients, rapid MR examinations were performed without any need for intravenous sedation or general anesthesia.
CONCLUSIONS: Our study results strongly suggest the superiority of the TSE sequence MR protocol compared to the SSh sequence protocol in pediatric patients with a programmable ventriculoperitoneal drainage system due to a significant reduction of susceptibility artifact volume. Both rapid sequence MR protocols provide quick and satisfactory brain imaging with no ionizing radiation and a reduced need for intravenous or general anesthesia.

Entities:  

Keywords:  Pediatric patients; Rapid magnetic resonance imaging; Susceptibility artifact; TSE sequence; Ventriculoperitoneal drainage

Mesh:

Year:  2017        PMID: 28342115     DOI: 10.1007/s00381-017-3385-2

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  8 in total

1.  Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: current situation and clinical perspective.

Authors:  M J W Götte; I K Rüssel; G J de Roest; T Germans; R F Veldkamp; P Knaapen; C P Allaart; A C van Rossum
Journal:  Neth Heart J       Date:  2010-01       Impact factor: 2.380

2.  Rapid brain magnetic resonance imaging: An alternative to head computed tomography for evaluation of ventricular shunt malfunction.

Authors:  Lori M Singleton
Journal:  J Pediatr       Date:  2016-01-16       Impact factor: 4.406

3.  Utility of computed tomography or magnetic resonance imaging evaluation of ventricular morphology in suspected cerebrospinal fluid shunt malfunction.

Authors:  Jonathan N Sellin; Jacob Cherian; James M Barry; Sheila L Ryan; Thomas G Luerssen; Andrew Jea
Journal:  J Neurosurg Pediatr       Date:  2014-05-23       Impact factor: 2.375

4.  Programmable CSF shunt valves: radiographic identification and interpretation.

Authors:  S Scott Lollis; A C Mamourian; T J Vaccaro; A-C Duhaime
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

5.  Test characteristics of quick brain MRI for shunt evaluation in children: an alternative modality to avoid radiation.

Authors:  Esther L Yue; Garth D Meckler; Ross J Fleischman; Nathan R Selden; Dianna M E Bardo; Amity K Chu O'Connor; Eugene T Vu; Rongwei Fu; David M Spiro
Journal:  J Neurosurg Pediatr       Date:  2015-01-30       Impact factor: 2.375

6.  Benefits of brain magnetic resonance imaging over computed tomography in children requiring emergency evaluation of ventriculoperitoneal shunt malfunction: reducing lifetime attributable risk of cancer.

Authors:  In Kim; Susan B Torrey; Sarah S Milla; Marisa C Torch; Michael G Tunik; Jessica C Foltin
Journal:  Pediatr Emerg Care       Date:  2015-04       Impact factor: 1.454

Review 7.  Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art.

Authors:  P Stradiotti; A Curti; G Castellazzi; A Zerbi
Journal:  Eur Spine J       Date:  2009-05-13       Impact factor: 3.134

8.  Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus.

Authors:  Brent R O'Neill; Sumit Pruthi; Harmanjeet Bains; Ryan Robison; Keiko Weir; Jeff Ojemann; Richard Ellenbogen; Anthony Avellino; Samuel R Browd
Journal:  World Neurosurg       Date:  2012-10-27       Impact factor: 2.104

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.