Electromagnetically tracked personalized templates for surgical navigation.

Andrew W L Dickinson1, Michelle L Zec1, David R Pichora1, Brian J Rasquinha1, Randy E Ellis2.   

Abstract

PURPOSE: An electromagnetic (EM) surgical tracking system was developed for orthopedic navigation. The reportedly poor accuracy of point-based EM navigation was improved by using anatomical impressions, which were EM-tracked personalized templates. Lines, rather than points, were consistently used for calibration and error evaluation.
METHODS: Technical accuracy was tested using models derived from CT scans of ten cadaver shoulders. Tracked impressions were first designed, calibrated, and tested using lines as fiducial objects. Next, tracked impressions were tested against EM point-based navigation and optical point-based navigation, in environments that were either relatively empty or that included surgical instruments. Finally, a tracked impression was tested on a cadaver forearm in a simulated fracture-repair task.
RESULTS: Calibration of anatomical impressions to EM tracking was highly accurate, with mean fiducial localization errors in positions of 0.3 mm and in angles of [Formula: see text]. Technical accuracy on physical shoulder models was also highly accurate; in an EM field with surgical instruments, the mean of target registration errors in positions was 2.2 mm and in angles was [Formula: see text]. Preclinical accuracy in a cadaver forearm in positions was 0.4 mm and in angles was [Formula: see text]. The technical accuracy was significantly better than point-based navigation, whether by EM tracking or by optical tracking. The preclinical accuracy was comparable to that achieved by point-based optical navigation.
CONCLUSIONS: EM-tracked impressions-a hybrid of personalized templates and EM navigation-are a promising technology for orthopedic applications. The two technical contributions are the novel hybrid navigation and the consistent use of lines as fiducial objects, replacing traditional point-based computations. The accuracy improvement was attributed to the combination of physical surfaces and line directions in the processes of calibration and registration. The technical studies and preclinical trial suggest that EM-tracked impressions are an accurate, ergonomic innovation in image-guided orthopedic surgery.

Keywords:  Electromagnetic tracking; Personalized templates; Surgical navigation; Target registration error

Mesh:

Year:  2017        PMID: 28332159     DOI: 10.1007/s11548-017-1563-z

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  13 in total

1.  Augmented virtuality for arthroscopic knee surgery.

Authors:  John M Li; Davide D Bardana; A James Stewart
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

2.  Design and application of an assessment protocol for electromagnetic tracking systems.

Authors:  Johann B Hummel; Michael R Bax; Michael L Figl; Yan Kang; Calvin Maurer; Wolfgang W Birkfellner; Helmar Bergmann; Ramin Shahidi
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

3.  Robust registration for computer-integrated orthopedic surgery: laboratory validation and clinical experience.

Authors:  B Ma; R E Ellis
Journal:  Med Image Anal       Date:  2003-09       Impact factor: 8.545

4.  Least-squares fitting of two 3-d point sets.

Authors:  K S Arun; T S Huang; S D Blostein
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1987-05       Impact factor: 6.226

5.  Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty.

Authors:  Gabriel Venne; Brian J Rasquinha; David Pichora; Randy E Ellis; Ryan Bicknell
Journal:  J Shoulder Elbow Surg       Date:  2015-01-01       Impact factor: 3.019

6.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

7.  Minimizing electromagnetic interference from surgical instruments on electromagnetic surgical navigation.

Authors:  Faustin Stevens; Michael A Conditt; Nikhil Kulkarni; Sabir K Ismaily; Philip C Noble; David R Lionberger
Journal:  Clin Orthop Relat Res       Date:  2010-05-29       Impact factor: 4.176

8.  Comparing position and orientation accuracy of different electromagnetic sensors for tracking during interventions.

Authors:  Jasper Nijkamp; Bram Schermers; Sander Schmitz; Sofieke de Jonge; Koert Kuhlmann; Ferdinand van der Heijden; Jan-Jakob Sonke; Theo Ruers
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-01-25       Impact factor: 2.924

9.  Computer-assisted hip resurfacing using individualized drill templates.

Authors:  Manuela Kunz; John F Rudan; George L Xenoyannis; Randy E Ellis
Journal:  J Arthroplasty       Date:  2009-05-22       Impact factor: 4.757

10.  Technical accuracy of optical and the electromagnetic tracking systems.

Authors:  Tapani Koivukangas; Jani Pa Katisko; John P Koivukangas
Journal:  Springerplus       Date:  2013-03-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.