| Literature DB >> 28302112 |
David Lyell1, Farah Magrabi2, Magdalena Z Raban3, L G Pont3, Melissa T Baysari3,4, Richard O Day5, Enrico Coiera2.
Abstract
BACKGROUND: Clinical decision support (CDS) in e-prescribing can improve safety by alerting potential errors, but introduces new sources of risk. Automation bias (AB) occurs when users over-rely on CDS, reducing vigilance in information seeking and processing. Evidence of AB has been found in other clinical tasks, but has not yet been tested with e-prescribing. This study tests for the presence of AB in e-prescribing and the impact of task complexity and interruptions on AB.Entities:
Keywords: Automation bias; Clinical; Cognitive biases; Complexity; Decision support systems; Electronic prescribing; Human-automation interaction; Human-computer interaction; Medication errors
Mesh:
Year: 2017 PMID: 28302112 PMCID: PMC5356416 DOI: 10.1186/s12911-017-0425-5
Source DB: PubMed Journal: BMC Med Inform Decis Mak ISSN: 1472-6947 Impact factor: 2.796
Fig. 1Experimental design with the number of participants in each condition. All participants completed all conditions. However, some were excluded from the analysis of interruption conditions as they did not trigger the interruption task
Fig. 2The e-prescribing system interface and scenario
Fig. 3CDS Alert
Prescribing errors
| Control | Quality of Decision Support | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| No CDS | Correct CDS | Incorrect CDS | Total | ||||||
| n | % | n | % | n | % | n | % | ||
| Omission errors | |||||||||
| Wrong drug | 57 | 35.8 | 7 | 25.0 | 116 | 41.9 | 180 | 38.8 | |
| Wrong dose | 55 | 34.6 | 9 | 32.1 | 72 | 26.0 | 136 | 29.3 | |
| Wrong frequency | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | |
| Drug-drug interaction | 28 | 17.6 | 7 | 25.0 | 60 | 21.7 | 95 | 20.5 | |
| Wrong route | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | |
| Wrong formulation | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | |
| Duplicated drug therapy | 19 | 11.9 | 5 | 17.9 | 29 | 10.5 | 53 | 11.4 | |
| Not indicated | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | |
| Not Prescribed | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | |
| Total omission errors | 159 | 28 | 277 | 464 | |||||
| Commission errors | |||||||||
| Not prescribed | 24 | 100.0 | 18 | 100.0 | 229 | 100.0 | 271 | 100.0 | |
| Total commission errors | 24 | 18 | 229 | 271 | |||||
| User originated errors | |||||||||
| Wrong drug | 8 | 5.8 | 10 | 11.6 | 9 | 9.9 | 27 | 8.6 | |
| Wrong dose | 43 | 31.4 | 29 | 33.7 | 22 | 24.2 | 94 | 29.9 | |
| Wrong frequency | 10 | 7.3 | 6 | 7.0 | 4 | 4.4 | 20 | 6.4 | |
| Drug-drug interaction | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | 0 | 0.0 | |
| Wrong route | 0 | 0.0 | 0 | 0.0 | 1 | 1.1 | 1 | 0.3 | |
| Wrong formulation | 1 | 0.7 | 0 | 0.0 | 0 | 0.0 | 1 | 0.3 | |
| Duplicated drug therapy | 0 | 0.0 | 0 | 0.0 | 1 | 1.1 | 1 | 0.3 | |
| Not indicated | 0 | 0.0 | 1 | 1.2 | 0 | 0.0 | 1 | 0.3 | |
| Not prescribed | 75 | 54.7 | 40 | 46.5 | 54 | 59.3 | 169 | 53.8 | |
| Total user originated errors | 137 | 86 | 91 | 314 | |||||
| Total errors | |||||||||
| Wrong drug | 65 | 20.3 | 17 | 12.9 | 125 | 20.9 | 207 | 19.7 | |
| Wrong dose | 98 | 30.6 | 38 | 28.8 | 94 | 15.7 | 230 | 21.9 | |
| Wrong frequency | 10 | 3.1 | 6 | 4.5 | 4 | 0.7 | 20 | 1.9 | |
| Drug-drug interaction | 28 | 8.8 | 7 | 5.3 | 60 | 10.1 | 95 | 9.1 | |
| Wrong route | 0 | 0.0 | 0 | 0.0 | 1 | 0.2 | 1 | 0.1 | |
| Wrong formulation | 1 | 0.3 | 0 | 0.0 | 0 | 0.0 | 1 | 0.1 | |
| Duplicated drug therapy | 19 | 5.9 | 5 | 3.8 | 30 | 5.0 | 54 | 5.1 | |
| Not indicated | 0 | 0.0 | 1 | 0.8 | 0 | 0.0 | 1 | 0.1 | |
| Not Prescribed | 99 | 30.9 | 58 | 43.9 | 283 | 47.4 | 440 | 41.9 | |
| Total errors | 320 | 132 | 597 | 1049 | |||||
Number of participants making omission and commission errors
| Scenario complexity | Quality of Decision Support | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Control (No CDS) | Correct CDS | Incorrect CDS | ||||||||||
| Omission | Commission | Omission | Commission | Omission | Commission | |||||||
| No alert | No alert | True positive alert | True negative alert | False negative alert | False positive alert | |||||||
| ( | ( | ( | ( | ( | ( | |||||||
| n | % | n | % | n | % | n | % | n | % | n | % | |
| Low | 55 | 45.8 | 4 | 3.3 | 9 | 7.5 | 5 | 4.2 | 95 | 79.2 | 83 | 69.2 |
| Low + Interrupta | 46 | 54.8 | 5 | 6 | 8 | 8.2 | 1 | 1 | 92 | 79.3 | 69 | 59.5 |
| High | 58 | 48.3 | 15 | 12.5 | 11 | 9.2 | 12 | 10 | 90 | 75 | 77 | 64.2 |
| Total | 159 | 49.1 | 24 | 7.4 | 28 | 8.3 | 18 | 5.3 | 277 | 77.8 | 229 | 64.3 |
aNumber of participants in low + interrupt conditions: Control (n = 84), Correct DS (n = 98), and Incorrect DS (n = 116)