Literature DB >> 28299704

Loop-Mediated Isothermal Amplification and LFD Combination for Detection of Plasmodium falciparum and Plasmodium vivax.

Darin Kongkasuriyachai1, Suganya Yongkiettrakul2, Wansika Kiatpathomchai2, Narong Arunrut2.   

Abstract

Loop-mediated isothermal amplification (LAMP) has been used to detect several pathogens including malaria parasites from field and clinical samples. In this protocol, the malaria LAMP technology is developed to differentiate between Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) species by targeting the dihydrofolate reductase thymidylate synthase (dhfr-ts) gene, a known target for the antifolate class of drugs such as Pyrimethamine. LAMP primer sets are designed and validated for species specific amplification. Additionally, specific probes help improve detection and visualization of the products when combined with lateral flow dipstick-based (LFD) detection. The protocols are further simplified to eliminate tedious sample preparation steps, such that crude lysis prepared simply by diluting few microliter (μL) of blood sample with distilled water is sufficient. The LAMP-LFD malaria dhfr-ts protocols are sensitive and can detect as little as 1 picogram (pg) of PfDNA and 1 nanogram (ng) of PvDNA, or a few microliters of crude lysate from infected blood samples (Yongkiettrakul et al., Parasitol Int 63: 777-784, 2014). These simplified steps not only reduce cost but also increase the potential for large application in the fields and clinical settings.

Entities:  

Keywords:  Detection; LAMP; LFD; Lateral flow dipstick; Loop-mediated isothermal amplification; Malaria; Plasmodium

Mesh:

Substances:

Year:  2017        PMID: 28299704     DOI: 10.1007/978-1-4939-6911-1_28

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  5 in total

1.  Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening patients with imported malaria in a non-endemic setting.

Authors:  Camille Ponce; Flora Kaczorowski; Thomas Perpoint; Patrick Miailhes; Alain Sigal; Etienne Javouhey; Yves Gillet; Laurent Jacquin; Marion Douplat; Karim Tazarourte; Véronique Potinet; Bruno Simon; Adeline Lavoignat; Guillaume Bonnot; Fatimata Sow; Anne-Lise Bienvenu; Stéphane Picot
Journal:  Parasite       Date:  2017-12-18       Impact factor: 3.000

2.  Poor Diagnostic Performance of a Species-Specific Loop-Mediated Isothermal Amplification (LAMP) Platform for Malaria.

Authors:  Hans Kollenda; Ralf Matthias Hagen; Miriam Hanke; Sandra Rojak; Rebecca Hinz; Lars Wassill; Sven Poppert; Egbert Tannich; Hagen Frickmann
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2018-09-28

Review 3.  Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms.

Authors:  Y-P Wong; S Othman; Y-L Lau; S Radu; H-Y Chee
Journal:  J Appl Microbiol       Date:  2018-02-12       Impact factor: 3.772

4.  Sensitive Immunoassay Detection of Plasmodium Lactate Dehydrogenase by Inductively Coupled Plasma Mass Spectrometry.

Authors:  Jianbing Mu; Lee L Yu; Thomas E Wellems
Journal:  Front Cell Infect Microbiol       Date:  2021-01-11       Impact factor: 5.293

5.  Loop-mediated isothermal amplification-lateral-flow dipstick (LAMP-LFD) to detect Mycoplasma ovipneumoniae.

Authors:  Jie Zhang; Junjun Cao; Mingsong Zhu; Mingguo Xu; Feng Shi
Journal:  World J Microbiol Biotechnol       Date:  2019-01-30       Impact factor: 3.312

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.