Literature DB >> 28281026

Neoatherosclerosis assessed with optical coherence tomography in restenotic bare metal and first- and second-generation drug-eluting stents.

Lei Song1,2,3, Gary S Mintz1, Dong Yin1,2,3, Myong Hwa Yamamoto1,2, Chee Yang Chin1,4, Mitsuaki Matsumura1, Khady Fall2, Ajay J Kirtane1,2, Manish A Parikh1,2, Jeffrey W Moses1,2, Ziad A Ali1,2, Richard A Shlofmitz5, Akiko Maehara6,7.   

Abstract

Although reported in bare metal stents (BMS) and first-generation drug-eluting stents (DES), little is known about neoatherosclerosis in second-generation DES. We used optical coherence tomography to evaluate neoatherosclerosis among different stent generations. Overall, 274 in-stent restenosis (ISR) lesions (duration from implantation 56.9 ± 47.2 months) in 274 patients were assessed for the presence of neoatherosclerosis. Neoatherosclerosis was identified in 38.7% of lesions (106/274): 23.0% second-generation DES (38/165), 65.1% first-generation DES (54/83), and 53.8% BMS (14/26). In the neoatherosclerosis cohort (n = 106), more stent underexpansion or fracture/deformation was observed in second-generation DES, whereas thrombus, without plaque rupture, or evagination was more common in first-generation DES. In multivariable analyses, duration from implantation >1 year (OR: 2.44, 95% CI 1.12-5.31; p = 0.03), absence of angiotensin-converting enzyme inhibitors/angiotensin II receptor blockers (OR 1.95, 95% CI 1.10-3.44; p = 0.02) or statins at the time of ISR (OR 3.12, 95% CI 1.42-6.84; p = 0.01), and first-generation vs first-generation DES (OR 5.32, 95% CI 2.82-10.10; p < 0.001) correlated with a higher prevalence of neoatherosclerosis. Duration from implantation <1 year (OR 2.17, 95% CI 1.03-4.55; p = 0.04) and thin fibrous cap, thrombus, or rupture (OR 2.72, 95% CI 1.15-6.39; p = 0.02) were independent predictors for acute coronary syndromes presentation. Neoatherosclerosis is an important ISR mechanism, especially in first generation DES.

Entities:  

Keywords:  Bare metal stent; Drug-eluting stent; Imaging; In-stent restenosis; Optical coherence tomography

Mesh:

Substances:

Year:  2017        PMID: 28281026     DOI: 10.1007/s10554-017-1106-2

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  28 in total

1.  Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage.

Authors:  Peter Barlis; Konstantinos Dimopoulos; Jun Tanigawa; Ewa Dzielicka; Giuseppe Ferrante; Francesca Del Furia; Carlo Di Mario
Journal:  Int J Cardiol       Date:  2009-01-19       Impact factor: 4.164

Review 2.  Neoatherosclerosis: overview of histopathologic findings and implications for intravascular imaging assessment.

Authors:  Fumiyuki Otsuka; Robert A Byrne; Kazuyuki Yahagi; Hiroyoshi Mori; Elena Ladich; David R Fowler; Robert Kutys; Erion Xhepa; Adnan Kastrati; Renu Virmani; Michael Joner
Journal:  Eur Heart J       Date:  2015-05-20       Impact factor: 29.983

3.  Two-year outcomes after first- or second-generation drug-eluting or bare-metal stent implantation in all-comer patients undergoing percutaneous coronary intervention: a pre-specified analysis from the PRODIGY study (PROlonging Dual Antiplatelet Treatment After Grading stent-induced Intimal hyperplasia studY).

Authors:  Marco Valgimigli; Matteo Tebaldi; Marco Borghesi; Pascal Vranckx; Gianluca Campo; Carlo Tumscitz; Elisa Cangiano; Monica Minarelli; Antonella Scalone; Caterina Cavazza; Jlenia Marchesini; Giovanni Parrinello
Journal:  JACC Cardiovasc Interv       Date:  2013-12-11       Impact factor: 11.195

4.  Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.

Authors:  Soo-Jin Kang; Gary S Mintz; Takashi Akasaka; Duk-Woo Park; Jong-Young Lee; Won-Jang Kim; Seung-Whan Lee; Young-Hak Kim; Cheol Whan Lee; Seong-Wook Park; Seung-Jung Park
Journal:  Circulation       Date:  2011-06-06       Impact factor: 29.690

5.  Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents.

Authors:  Adnan Kastrati; Julinda Mehilli; Jürgen Pache; Christoph Kaiser; Marco Valgimigli; Henning Kelbaek; Maurizio Menichelli; Manel Sabaté; Maarten J Suttorp; Dietrich Baumgart; Melchior Seyfarth; Matthias E Pfisterer; Albert Schömig
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

6.  Optical coherence tomographic observation of in-stent neoatherosclerosis in lesions with more than 50% neointimal area stenosis after second-generation drug-eluting stent implantation.

Authors:  Seung-Yul Lee; Seung-Ho Hur; Sang-Gon Lee; Sang-Wook Kim; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Circ Cardiovasc Interv       Date:  2015-02       Impact factor: 6.546

7.  Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.

Authors:  Stéphane Cook; Elena Ladich; Gaku Nakazawa; Parham Eshtehardi; Michel Neidhart; Rolf Vogel; Mario Togni; Peter Wenaweser; Michael Billinger; Christian Seiler; Steffen Gay; Bernhard Meier; Werner J Pichler; Peter Jüni; Renu Virmani; Stephan Windecker
Journal:  Circulation       Date:  2009-07-20       Impact factor: 29.690

8.  In-Stent Restenosis Caused by a Calcified Nodule: A Novel Pattern of Neoatherosclerosis.

Authors:  Fernando Alfonso; Javier Cuesta; Teresa Bastante; María Cruz Aguilera; Amparo Benedicto; Fernando Rivero
Journal:  Can J Cardiol       Date:  2015-08-20       Impact factor: 5.223

9.  Incidence and Clinical Impact of Stent Fracture After PROMUS Element Platinum Chromium Everolimus-Eluting Stent Implantation.

Authors:  Shoichi Kuramitsu; Takashi Hiromasa; Soichiro Enomoto; Tomohiro Shinozaki; Masashi Iwabuchi; Toru Mazaki; Takenori Domei; Kyohei Yamaji; Yoshimitsu Soga; Makoto Hyodo; Shinichi Shirai; Kenji Ando
Journal:  JACC Cardiovasc Interv       Date:  2015-07-22       Impact factor: 11.195

10.  Quantitative ex vivo and in vivo comparison of lumen dimensions measured by optical coherence tomography and intravascular ultrasound in human coronary arteries.

Authors:  Nieves Gonzalo; Patrick W Serruys; Héctor M García-García; Gijs van Soest; Takayuki Okamura; Jurgen Ligthart; Michiel Knaapen; Stefan Verheye; Nico Bruining; Evelyn Regar
Journal:  Rev Esp Cardiol       Date:  2009-06       Impact factor: 4.753

View more
  2 in total

1.  Cardiovascular imaging 2017 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Amer Alaiti; Hiram G Bezerra; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2018-06       Impact factor: 2.357

Review 2.  Intravascular imaging in coronary stent restenosis: Prevention, characterization, and management.

Authors:  Amr Abouelnour; Tommaso Gori
Journal:  Front Cardiovasc Med       Date:  2022-08-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.