| Literature DB >> 28278561 |
Jin Suk Bae1, Dong Hyun Kim1,2, Won Taek Kim1,2, Yong Ho Kim1, Dahl Park1,2, Yong Kan Ki1,2.
Abstract
PURPOSE: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). METHODS AND MATERIALS: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ≤2 cm) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions.Entities:
Keywords: Clip; Hepatobiliary cancer; Interfractional error; Pancreatic cancer; Postoperative radiotherapy
Year: 2017 PMID: 28278561 PMCID: PMC5398350 DOI: 10.3857/roj.2016.02019
Source DB: PubMed Journal: Radiat Oncol J ISSN: 2234-1900
Patients’ characteristics
| Characteristic | No. of patients |
|---|---|
| Age (yr), median (range) | 62 (49–75) |
| Sex | |
| Male | 17 |
| Female | 3 |
| Diagnosis | |
| Cholangiocarcinoma | 9 |
| Intrahepatic | 1 |
| Hilar | 2 |
| Distal | 6 |
| Pancreatic cancer | 6 |
| Ampulla of Vater cancer | 3 |
| Gallbladder cancer | 1 |
| Stomach cancer | 1 |
| Surgical technique | |
| Pylorus-preserving PD | 8 |
| Liver resection, bile duct resection | 6 |
| Whipple’s operation | 4 |
| Cholecystectomy | 1 |
| Subtotal stomach-preserving PD/SMV resection | 1 |
PD, pancreaticoduodenectomy; SMV, superior mesenteric vein.
Fig. 1.The location of 6 clips in digitally reconstructed radiographs (A) and kilovoltage images (B). Clips were consist of 3 proximal clips (red, clip_p, ≤2 cm) and 3 distal clips (blue, clip_d, >2 cm), which were classified according to distance from treatment center. The magenta, sky, and yellow lines show the planning target volume contours, right diaphragm, and left diaphragm, respectively.
Fig. 2.Scatter plot of clip shift in SI (A, B), AP (C, D), and RL (E, F) directions. SI, superior-inferior; AP, anterior-posterior; RL, right-left; p, proximal clip; d, distal clip.
Fig. 3.(A, B) Box plot of inter-fractional clip position change in SI direction. SI, superior-inferior; p, proximal clip; d, distal clip.