Ultraviolet (UV)-reflective paint with ultraviolet germicidal irradiation (UVGI) improves decontamination of nosocomial bacteria on hospital room surfaces.

Katelyn C Jelden1, Shawn G Gibbs2, Philip W Smith3, Angela L Hewlett3, Peter C Iwen4,5, Kendra K Schmid6, John J Lowe1.   

Abstract

An ultraviolet germicidal irradiation (UVGI) generator (the TORCH, ClorDiSys Solutions, Inc.) was used to compare the disinfection of surface coupons (plastic from a bedrail, stainless steel, and chrome-plated light switch cover) in a hospital room with walls coated with ultraviolet (UV)-reflective paint (Lumacept) or standard paint. Each surface coupon was inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE), placed at 6 different sites within a hospital room coated with UV-reflective paint or standard paint, and treated by 10 min UVC exposure (UVC dose of 0-688 mJ/cm2 between sites with standard paint and 0-553 mJ/cm2 with UV-reflective paint) in 8 total trials. Aggregated MRSA concentrations on plastic bedrail surface coupons were reduced on average by 3.0 log10 (1.8 log10 Geometric Standard Deviation [GSD]) with standard paint and 4.3 log10 (1.3 log10 GSD) with UV-reflective paint (p = 0.0005) with no significant reduction differences between paints on stainless steel and chrome. Average VRE concentrations were reduced by ≥4.9 log10 (<1.2 log10 GSD) on all surface types with UV-reflective paint and ≤4.1 log10 (<1.7 log10 GSD) with standard paint (p < 0.05). At 5 aggregated sites directly exposed to UVC light, MRSA concentrations on average were reduced by 5.2 log10 (1.4 log10 GSD) with standard paint and 5.1 log10 (1.2 log10 GSD) with UV-reflective paint (p = 0.017) and VRE by 4.4 log10 (1.4 log10 GSD) with standard paint and 5.3 log10 (1.1 log10 GSD) with UV-reflective paint (p < 0.0001). At one indirectly exposed site on the opposite side of the hospital bed from the UVGI generator, MRSA concentrations on average were reduced by 1.3 log10 (1.7 log10 GSD) with standard paint and 4.7 log10 (1.3 log10 GSD) with UV-reflective paint (p < 0.0001) and VRE by 1.2 log10 (1.5 log10 GSD) with standard paint and 4.6 log10 (1.1 log10 GSD) with UV-reflective paint (p < 0.0001). Coating hospital room walls with UV-reflective paint enhanced UVGI disinfection of nosocomial bacteria on various surfaces compared to standard paint, particularly at a surface placement site indirectly exposed to UVC light.

Entities:  

Keywords:  Environmental decontamination; UV-reflective paint; hospital room; surfaces; ultraviolet germicidal irradiation

Mesh:

Year:  2017        PMID: 28278065     DOI: 10.1080/15459624.2017.1296231

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  2 in total

1.  Ambulance disinfection using Ultraviolet Germicidal Irradiation (UVGI): Effects of fixture location and surface reflectivity.

Authors:  William G Lindsley; Tia L McClelland; Dylan T Neu; Stephen B Martin; Kenneth R Mead; Robert E Thewlis; John D Noti
Journal:  J Occup Environ Hyg       Date:  2018-01       Impact factor: 2.155

2.  Comparing and optimizing ultraviolet germicidal irradiation systems use for patient room terminal disinfection: an exploratory study using radiometry and commercial test cards.

Authors:  Vincent Masse; Michael J Hartley; Michael B Edmond; Daniel J Diekema
Journal:  Antimicrob Resist Infect Control       Date:  2018-02-22       Impact factor: 4.887

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.