A Feasibility Study of Using Hybrid Collimation for Nuclear Environment.

L J Meng1, D K Wehe1.   

Abstract

This paper presents a feasibility of a gamma ray imager using combined electronic and mechanical collimation methods. This detector is based on the use of a multiple pinhole collimator, a position sensitive scintillation detector with Anger logic readout. A pixelated semiconductor detector, located between the collimator and the scintillation detector, is used as a scattering detector. For gamma rays scattered in the first detector and then stopped in the second detector, an image can also be built up based on the joint probability of their passing through the collimator and falling into a broadened conical surface, defined by the detected Compton scattering event. Since these events have a much smaller angular uncertainty, they provide more information content per photon compared with using solely the mechanical or electronic collimation. Therefore, the overall image quality can be improved. This feasibility study adapted a theoretical approach, based on analysing the resolution-variance trade-off in images reconstructed using Maximum a priori (MAP) algorithm. The effect of factors such as the detector configuration, Doppler broadening and collimator configuration are studied. The results showed that the combined collimation leads to a significant improvement in image quality at energy range below 300keV. However, due to the mask penetration, the performance of such a detector configuration is worse than a standard Compton camera at above this energy.

Entities:  

Keywords:  Compton-scattering; environmental imager

Year:  2003        PMID: 28260807      PMCID: PMC5333790          DOI: 10.1109/TNS.2003.815135

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  2 in total

1.  A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data.

Authors:  J Qi; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1999-04       Impact factor: 10.048

2.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs.

Authors:  J A Fessler; W L Rogers
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

  2 in total
  3 in total

1.  A modified uniform Cramer-Rao bound for multiple pinhole aperture design.

Authors:  L J Meng; N H Clinthorne
Journal:  IEEE Trans Med Imaging       Date:  2004-07       Impact factor: 10.048

Review 2.  Compton imaging for medical applications.

Authors:  Hideaki Tashima; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2022-07-22

3.  SPECT system optimization against a discrete parameter space.

Authors:  L J Meng; N Li
Journal:  Phys Med Biol       Date:  2013-04-15       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.