Literature DB >> 28239509

System Design and Development of a Robotic Device for Automated Venipuncture and Diagnostic Blood Cell Analysis.

Max L Balter1, Alvin I Chen1, Alex Fromholtz1, Alex Gorshkov1, Tim J Maguire2, Martin L Yarmush3.   

Abstract

Diagnostic blood testing is the most prevalent medical procedure performed in the world and forms the cornerstone of modern health care delivery. Yet blood tests are still predominantly carried out in centralized labs using large-volume samples acquired by manual venipuncture, and no end-to-end solution from blood draw to sample analysis exists today. Our group is developing a platform device that merges robotic phlebotomy with automated diagnostics to rapidly deliver patient information at the site of the blood draw. The system couples an image-guided venipuncture robot, designed to address the challenges of routine venous access, with a centrifuge-based blood analyzer to obtain quantitative measurements of hematology. In this paper, we first present the system design and architecture of the integrated device. We then perform a series of in vitro experiments to evaluate the cannulation accuracy of the system on blood vessel phantoms. Next, we assess the effects of vessel diameter, needle gauge, flow rate, and viscosity on the rate of sample collection. Finally, we demonstrate proof-of-concept of a white cell assay on the blood analyzer using in vitro human samples spiked with fluorescently labeled microbeads.

Entities:  

Year:  2016        PMID: 28239509      PMCID: PMC5321615          DOI: 10.1109/IROS.2016.7759102

Source DB:  PubMed          Journal:  Rep U S        ISSN: 2153-0858


  10 in total

Review 1.  Commercialization of microfluidic point-of-care diagnostic devices.

Authors:  Curtis D Chin; Vincent Linder; Samuel K Sia
Journal:  Lab Chip       Date:  2012-02-17       Impact factor: 6.799

Review 2.  Centrifugal microfluidics for biomedical applications.

Authors:  Robert Gorkin; Jiwoon Park; Jonathan Siegrist; Mary Amasia; Beom Seok Lee; Jong-Myeon Park; Jintae Kim; Hanshin Kim; Marc Madou; Yoon-Kyoung Cho
Journal:  Lab Chip       Date:  2010-05-28       Impact factor: 6.799

3.  National Hospital Ambulatory Medical Care Survey: 2007 emergency department summary.

Authors:  Richard Niska; Farida Bhuiya; Jianmin Xu
Journal:  Natl Health Stat Report       Date:  2010-08-06

4.  Drop-to-drop variation in the cellular components of fingerprick blood: implications for point-of-care diagnostic development.

Authors:  Meaghan M Bond; Rebecca R Richards-Kortum
Journal:  Am J Clin Pathol       Date:  2015-12       Impact factor: 2.493

Review 5.  Laboratory automation: total and subtotal.

Authors:  Charles D Hawker
Journal:  Clin Lab Med       Date:  2007-12       Impact factor: 1.935

6.  Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties.

Authors:  Alvin I Chen; Max L Balter; Melanie I Chen; Daniel Gross; Sheikh K Alam; Timothy J Maguire; Martin L Yarmush
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

7.  Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance.

Authors:  Max L Balter; Alvin I Chen; Timothy J Maguire; Martin L Yarmush
Journal:  IEEE Trans Ind Electron       Date:  2016-04-21       Impact factor: 8.236

8.  The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot.

Authors:  Max L Balter; Alvin I Chen; Timothy J Maguire; Martin L Yarmush
Journal:  IEEE Trans Robot       Date:  2015-08       Impact factor: 5.567

9.  Real-time Needle Steering in Response to Rolling Vein Deformation by a 9-DOF Image-Guided Autonomous Venipuncture Robot.

Authors:  Alvin I Chen; Max L Balter; Timothy J Maguire; Martin L Yarmush
Journal:  Rep U S       Date:  2015 Sep-Oct

10.  The use of the white cell count and haemoglobin in combination as an effective screen to predict the normality of the full blood count.

Authors:  A Osei-Bimpong; R McLean; E Bhonda; S M Lewis
Journal:  Int J Lab Hematol       Date:  2011-08-24       Impact factor: 2.877

  10 in total
  2 in total

1.  Design and Evaluation of a Handheld Robotic Device for Peripheral Catheterization.

Authors:  Josh Leipheimer; Max Balter; Alvin Chen; Martin Yarmush
Journal:  J Med Device       Date:  2022-03-02       Impact factor: 0.743

Review 2.  Anemia in salmon aquaculture: Scotland as a case study.

Authors:  A R Currie; D Cockerill; M Diez-Padrisa; H Haining; F L Henriquez; B Quinn
Journal:  Aquaculture       Date:  2022-01-15       Impact factor: 4.242

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.