Literature DB >> 26779381

Real-time Needle Steering in Response to Rolling Vein Deformation by a 9-DOF Image-Guided Autonomous Venipuncture Robot.

Alvin I Chen1, Max L Balter2, Timothy J Maguire3, Martin L Yarmush4.   

Abstract

Venipuncture is the most common invasive medical procedure performed in the United States and the number one cause of hospital injury. Failure rates are particularly high in pediatric and elderly patients, whose veins tend to deform, move, or roll as the needle is introduced. To improve venipuncture accuracy in challenging patient populations, we have developed a portable device that autonomously servos a needle into a suitable vein under image guidance. The device operates in real time, combining near-infrared and ultrasound imaging, computer vision software, and a 9 degrees-of-freedom robot that servos the needle. In this paper, we present the kinematic and mechanical design of the latest generation robot. We then investigate in silico and in vitro the mechanics of vessel rolling and deformation in response to needle insertions performed by the robot. Finally, we demonstrate how the robot can make real-time adjustments under ultrasound image guidance to compensate for subtle vessel motions during venipuncture.

Entities:  

Year:  2015        PMID: 26779381      PMCID: PMC4714798          DOI: 10.1109/IROS.2015.7353736

Source DB:  PubMed          Journal:  Rep U S        ISSN: 2153-0858


  9 in total

1.  Force modeling for needle insertion into soft tissue.

Authors:  Allison M Okamura; Christina Simone; Mark D O'Leary
Journal:  IEEE Trans Biomed Eng       Date:  2004-10       Impact factor: 4.538

2.  The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experiments.

Authors:  F M Hendriks; D Brokken; C W J Oomens; D L Bader; F P T Baaijens
Journal:  Med Eng Phys       Date:  2005-08-11       Impact factor: 2.242

Review 3.  Vascular access management 1: an overview.

Authors:  Margaret McCann; Hildur Einarsdóttir; Jean-Pierre Van Waeleghem; F Murphy; J Sedgewick
Journal:  J Ren Care       Date:  2008-06

Review 4.  Difficult venous access in children: taking control.

Authors:  Laura L Kuensting; Scott DeBoer; Reneé Holleran; Barbara L Shultz; Rebecca A Steinmann; Jeanne Venella
Journal:  J Emerg Nurs       Date:  2009-03-21       Impact factor: 1.836

5.  Use of puncture force measurement to investigate the conditions of blood vessel needle insertion.

Authors:  Yo Kobayashi; Ryutaro Hamano; Hiroki Watanabe; Jaesung Hong; Kazutaka Toyoda; Makoto Hashizume; Masakatsu G Fujie
Journal:  Med Eng Phys       Date:  2013-01-14       Impact factor: 2.242

6.  Ultrasound or near-infrared vascular imaging to guide peripheral intravenous catheterization in children: a pragmatic randomized controlled trial.

Authors:  Sarah J Curtis; William R Craig; Erin Logue; Ben Vandermeer; Amanda Hanson; Terry Klassen
Journal:  CMAJ       Date:  2015-04-20       Impact factor: 8.262

7.  Portable robot for autonomous venipuncture using 3D near infrared image guidance.

Authors:  Alvin Chen; Kevin Nikitczuk; Jason Nikitczuk; Tim Maguire; Martin Yarmush
Journal:  Technology (Singap World Sci)       Date:  2013-09

8.  The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot.

Authors:  Max L Balter; Alvin I Chen; Timothy J Maguire; Martin L Yarmush
Journal:  IEEE Trans Robot       Date:  2015-08       Impact factor: 5.567

9.  Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery.

Authors:  Gerhardt Konig; Todd N McAllister; Nathalie Dusserre; Sergio A Garrido; Corey Iyican; Alicia Marini; Alex Fiorillo; Hernan Avila; Wojciech Wystrychowski; Krzysztof Zagalski; Marcin Maruszewski; Alyce Linthurst Jones; Lech Cierpka; Luis M de la Fuente; Nicolas L'Heureux
Journal:  Biomaterials       Date:  2008-12-25       Impact factor: 12.479

  9 in total
  6 in total

1.  SCADE: Simultaneous Sensor Calibration and Deformation Estimation of FBG-Equipped Unmodeled Continuum Manipulators.

Authors:  Farshid Alambeigi; Sahba Aghajani Pedram; Jason L Speyer; Jacob Rosen; Iulian Iordachita; Russell H Taylor; Mehran Armand
Journal:  IEEE Trans Robot       Date:  2019-10-29       Impact factor: 5.567

2.  3D Near Infrared and Ultrasound Imaging of Peripheral Blood Vessels for Real-Time Localization and Needle Guidance.

Authors:  Alvin I Chen; Max L Balter; Timothy J Maguire; Martin L Yarmush
Journal:  Med Image Comput Comput Assist Interv       Date:  2016-10-02

3.  Automated end-to-end blood testing at the point-of-care: Integration of robotic phlebotomy with downstream sample processing.

Authors:  M L Balter; J M Leipheimer; A I Chen; A Shrirao; T J Maguire; M L Yarmush
Journal:  Technology (Singap World Sci)       Date:  2018-06

4.  Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance.

Authors:  Max L Balter; Alvin I Chen; Timothy J Maguire; Martin L Yarmush
Journal:  IEEE Trans Ind Electron       Date:  2016-04-21       Impact factor: 8.236

5.  System Design and Development of a Robotic Device for Automated Venipuncture and Diagnostic Blood Cell Analysis.

Authors:  Max L Balter; Alvin I Chen; Alex Fromholtz; Alex Gorshkov; Tim J Maguire; Martin L Yarmush
Journal:  Rep U S       Date:  2016-12-01

6.  Novel Opportunities for Improving the Quality of Preanalytical Phase. A Glimpse to the Future?

Authors:  Giuseppe Lippi; Janne Cadamuro
Journal:  J Med Biochem       Date:  2017-10-28       Impact factor: 3.402

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.