Literature DB >> 28203730

Influence of head and neck position on ventilation using the air-Q® SP airway in anaesthetized paralysed patients: a prospective randomized crossover study.

H J Kim, K Lee, S Bai, M H Kim, E Oh, Y C Yoo.   

Abstract

Background: The influence of different head and neck positions on the effectiveness of ventilation with the air-Q® self-pressurizing airway remains unevaluated. This study aimed to evaluate the influence of different head and neck positions on ventilation with the air-Q® SP airway.
Methods: In this prospective, randomized crossover study, we enrolled 51 female patients who were to undergo elective gynaecological or breast surgery under general anaesthesia. An air-Q® SP airway was placed in all patients, and mechanical ventilation was performed using a volume-controlled mode with a tidal volume of 10 ml kg−1 and a respiratory rate of 12 bpm. The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score were assessed first for the neutral head position and then for the extended, flexed, and rotated head positions in a random order.
Results: All parameters were similar for the rotated head and neck position and the neutral position. Compared with the neutral position, the oropharyngeal leak pressure and peak inspiratory pressure decreased in the extended position but increased significantly in the flexed position (P<0.001). However, the expiratory tidal volume and ventilation score decreased significantly in only the extended position (P<0.001) but were similar in the flexed and neutral positions. Conclusions: Ventilation was not adversely affected in the rotated or flexed head and neck positions, whereas head and neck extension negatively influenced ventilation. Clinically, it is better to avoid head and neck extension during ventilation with an air-Q® SP airway. Clinical trial registration: NCT02402387.
© The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

Entities:  

Mesh:

Year:  2017        PMID: 28203730     DOI: 10.1093/bja/aew448

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  Efficacy and Safety of Flexible Laryngeal Mask Ventilation in Otologic Surgery: A Retrospective Analysis.

Authors:  Feihong Liu; Chunhua Xi; Xu Cui; Guyan Wang
Journal:  Risk Manag Healthc Policy       Date:  2022-05-09

2.  Conditions for laryngeal mask airway placement in terms of oropharyngeal leak pressure: a comparison between blind insertion and laryngoscope-guided insertion.

Authors:  Go Wun Kim; Jong Yeop Kim; Soo Jin Kim; Yeo Rae Moon; Eun Jeong Park; Sung Yong Park
Journal:  BMC Anesthesiol       Date:  2019-01-05       Impact factor: 2.217

3.  Influence of head and neck position on the performance of supraglottic airway devices: A systematic review and meta-analysis.

Authors:  Min-Soo Kim; Jin Ha Park; Ki-Young Lee; Seung Ho Choi; Hwan Ho Jung; Ji-Ho Kim; Bora Lee
Journal:  PLoS One       Date:  2019-05-09       Impact factor: 3.240

4.  Lightwand-Guided Insertion of Flexible Reinforced Laryngeal Mask Airway: Comparison with Standard Digital Manipulation Insertion.

Authors:  Dae Hee Kim; Yun Jeong Chae; Sang Kee Min; Eun Ji Ha; Ji Young Yoo
Journal:  Med Sci Monit       Date:  2021-01-11

5.  Effects of Passive Head-and-Neck Movements on the Performance of i-gel® Supraglottic Airway Device in Anesthetized Patients - A Randomized Crossover Trial.

Authors:  Shreyasi Ray; Jyotirmay Kirtania
Journal:  Anesth Essays Res       Date:  2020-10-12

6.  Safety, efficacy and airway complications of the flexible laryngeal mask airway in functional endoscopic sinus surgery: A retrospective study of 6661 patients.

Authors:  Chunhua Xi; Dongjing Shi; Xu Cui; Guyan Wang
Journal:  PLoS One       Date:  2021-02-04       Impact factor: 3.240

7.  Influence of head and neck positions on oropharyngeal seal pressure with Baska mask® versus I-gel™; A randomised clinical study.

Authors:  Gurkaran Kaur Sidhu; Seema Jindal; Rupali Mahajan; Sheetal Bhagat
Journal:  Indian J Anaesth       Date:  2020-07-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.