Literature DB >> 28192907

Automated Trapping Column Exchanger for High-Throughput Nanoflow Liquid Chromatography.

Sandra E Spencer1, Thomas N Corso2, James G Bollinger1, Clark M Henderson3, Andrew N Hoofnagle3, Michael J MacCoss1.   

Abstract

As compared to conventional high-performance liquid chromatography (HPLC) techniques, nanoflow HPLC exhibits improved sensitivity and limits of detection. However, nanoflow HPLC suffers from low throughput due to instrument failure (e.g., fitting fatigue and trapping column failure), limiting the utility of the technique for clinical and industrial applications. To increase the robustness of nanoflow HPLC, we have developed and tested a trapping column exchanging robot for autonomous interchange of trapping columns. This robot makes reproducible, automated connections between the active trapping column and the rest of the HPLC system. The intertrapping column retention time is shown to be sufficiently reproducible for scheduled selected reaction monitoring assays to be performed on different trapping columns without rescheduling the selection windows.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28192907      PMCID: PMC5798597          DOI: 10.1021/acs.analchem.6b04227

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics.

Authors:  Yufeng Shen; Rui Zhao; Scott J Berger; Gordon A Anderson; Nestor Rodriguez; Richard D Smith
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

2.  Specific detection of anabasine, nicotine, and nicotine metabolites in urine by liquid chromatography-tandem mass spectrometry.

Authors:  Andrew N Hoofnagle; Thomas J Laha; Petrie M Rainey; Sayed M H Sadrzadeh
Journal:  Am J Clin Pathol       Date:  2006-12       Impact factor: 2.493

3.  LC-MS/MS in the Clinical Laboratory - Where to From Here?

Authors:  Stefan Kg Grebe; Ravinder J Singh
Journal:  Clin Biochem Rev       Date:  2011-02

4.  Development and characterization of a novel plug and play liquid chromatography-mass spectrometry (LC-MS) source that automates connections between the capillary trap, column, and emitter.

Authors:  Michael S Bereman; Edward J Hsieh; Thomas N Corso; Colleen K Van Pelt; Michael J Maccoss
Journal:  Mol Cell Proteomics       Date:  2013-02-19       Impact factor: 5.911

Review 5.  The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry.

Authors:  Andrew N Hoofnagle; Mark H Wener
Journal:  J Immunol Methods       Date:  2009-06-16       Impact factor: 2.303

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.