Abstract

PURPOSE OF REVIEW: Cardiac positron emission tomography (PET) images often contain errors due to cardiac, respiratory, and patient motion during relatively long image acquisition. Advanced motion compensation techniques may improve PET spatial resolution, eliminate potential artifacts, and ultimately improve the research and clinical capabilities of PET. RECENT
FINDINGS: Combined cardiac and respiratory gating has only recently been implemented in clinical PET systems. Considering that the gated image bins contain much lower counts than the original PET data, they need to be summed after correcting for motion, forming motion-corrected, high-count image volume. Furthermore, automated image registration techniques can be used to correct for motion between CT attenuation scan and PET acquisition. While motion correction methods are not yet widely used in clinical practice, approaches including dual-gated non-rigid motion correction and the incorporation of motion correction information into the reconstruction process have the potential to markedly improve cardiac PET imaging.

Entities:  

Keywords:  Cardiac PET imaging; Coronary imaging; Gated PET; PET motion correction

Mesh:

Year:  2017        PMID: 28185169     DOI: 10.1007/s11886-017-0825-2

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  55 in total

1.  Acquiring 4D thoracic CT scans using a multislice helical method.

Authors:  P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

2.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

3.  Displacement and velocity of the coronary arteries: cardiac and respiratory motion.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

4.  Enhanced definition PET for cardiac imaging.

Authors:  Ludovic Le Meunier; Piotr J Slomka; Damini Dey; Amit Ramesh; Louis E J Thomson; Sean W Hayes; John D Friedman; Victor Cheng; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2010-02-12       Impact factor: 5.952

5.  Dual cardiac-respiratory gated PET: implementation and results from a feasibility study.

Authors:  Axel Martinez-Möller; Darko Zikic; René M Botnar; Ralph A Bundschuh; William Howe; Sibylle I Ziegler; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-21       Impact factor: 9.236

6.  Practical PET Respiratory Motion Correction in Clinical PET/MR.

Authors:  Richard Manber; Kris Thielemans; Brian F Hutton; Anna Barnes; Sébastien Ourselin; Simon Arridge; Celia O'Meara; Simon Wan; David Atkinson
Journal:  J Nucl Med       Date:  2015-05-07       Impact factor: 10.057

Review 7.  Clinical myocardial perfusion PET/CT.

Authors:  Marcelo F Di Carli; Sharmila Dorbala; Jolene Meserve; Georges El Fakhri; Arkadiusz Sitek; Stephen C Moore
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

8.  Motion Correction of 18F-NaF PET for Imaging Coronary Atherosclerotic Plaques.

Authors:  Mathieu Rubeaux; Nikhil V Joshi; Marc R Dweck; Alison Fletcher; Manish Motwani; Louise E Thomson; Guido Germano; Damini Dey; Debiao Li; Daniel S Berman; David E Newby; Piotr J Slomka
Journal:  J Nucl Med       Date:  2015-10-15       Impact factor: 10.057

9.  Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging.

Authors:  Mojtaba Jafari Tadi; Tero Koivisto; Mikko Pänkäälä; Ari Paasio
Journal:  Int J Biomed Imaging       Date:  2014-07-10

10.  Demons versus Level-Set motion registration for coronary 18F-sodium fluoride PET.

Authors:  Mathieu Rubeaux; Nikhil Joshi; Marc R Dweck; Alison Fletcher; Manish Motwani; Louise E Thomson; Guido Germano; Damini Dey; Daniel S Berman; David E Newby; Piotr J Slomka
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-21
View more
  18 in total

1.  Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Ajmal; Saira Farid; John C O'Horo; Panithaya Chareonthaitawee; Larry M Baddour; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-10-30       Impact factor: 5.952

2.  Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Farid; Saira Ajmal; Geoffrey B Johnson; Larry M Baddour; Panithaya Chareonthaitawee; Paul A Friedman; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-09-14       Impact factor: 5.952

Review 3.  Motion Correction and Its Impact on Absolute Myocardial Blood Flow Measures with PET.

Authors:  Marina Piccinelli; John R Votaw; Ernest V Garcia
Journal:  Curr Cardiol Rep       Date:  2018-03-24       Impact factor: 2.931

Review 4.  Gating Approaches in Cardiac PET Imaging.

Authors:  Martin Lyngby Lassen; Jacek Kwiecinski; Piotr J Slomka
Journal:  PET Clin       Date:  2019-02-01

5.  Rescued diagnostic quality by motion correction of dynamic cardiac positron emission tomography (PET) perfusion images.

Authors:  Andrea D Thompson; Edward P Ficaro; Venkatesh L Murthy; Richard L Weinberg
Journal:  J Nucl Cardiol       Date:  2018-01-22       Impact factor: 5.952

6.  Body motion detection and correction in cardiac PET: Phantom and human studies.

Authors:  Tao Sun; Yoann Petibon; Paul K Han; Chao Ma; Sally J W Kim; Nathaniel M Alpert; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2019-10-08       Impact factor: 4.071

7.  Feasibility of Coronary 18F-Sodium Fluoride Positron-Emission Tomography Assessment With the Utilization of Previously Acquired Computed Tomography Angiography.

Authors:  Jacek Kwiecinski; Philip D Adamson; Martin L Lassen; Mhairi K Doris; Alastair J Moss; Sebastian Cadet; Maurits A Jansen; Damini Dey; Sang-Eun Lee; Mijin Yun; Hyuk-Jae Chang; Marc R Dweck; David E Newby; Daniel S Berman; Piotr J Slomka
Journal:  Circ Cardiovasc Imaging       Date:  2018-12       Impact factor: 7.792

8.  Automated dynamic motion correction using normalized gradient fields for 82rubidium PET myocardial blood flow quantification.

Authors:  Benjamin C Lee; Jonathan B Moody; Alexis Poitrasson-Rivière; Amanda C Melvin; Richard L Weinberg; James R Corbett; Venkatesh L Murthy; Edward P Ficaro
Journal:  J Nucl Cardiol       Date:  2018-11-07       Impact factor: 5.952

9.  Analytical quantification of aortic valve 18F-sodium fluoride PET uptake.

Authors:  Daniele Massera; Mhairi K Doris; Sebastien Cadet; Jacek Kwiecinski; Tania A Pawade; Frederique E C M Peeters; Damini Dey; David E Newby; Marc R Dweck; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2018-11-29       Impact factor: 5.952

10.  Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR.

Authors:  Thibault Marin; Yanis Djebra; Paul K Han; Yanis Chemli; Isabelle Bloch; Georges El Fakhri; Jinsong Ouyang; Yoann Petibon; Chao Ma
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.