Hongge Shu1,2, Jie Sun2, Thomas S Hatsukami3, Niranjan Balu2, Daniel S Hippe2, Haining Liu4, Ted R Kohler3,5, Wenzhen Zhu1, Chun Yuan2,4. 1. Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan, China. 2. Department of Radiology, University of Washington, Seattle, Washington, USA. 3. Department of Surgery, University of Washington, Seattle, Washington, USA. 4. Department of Bioengineering, University of Washington, Seattle, Washington, USA. 5. Surgery and Perioperative Care, VA Puget Sound Health Care System, Seattle, Washington, USA.
Abstract
PURPOSE: To evaluate in a proof-of-concept study the feasibility of Simultaneous Noncontrast Angiography and intraPlaque hemorrhage (SNAP) imaging as a clinical magnetic resonance angiography (MRA) technique for measuring carotid stenosis. There is a growing interest in detecting intraplaque hemorrhage (IPH) during the clinical management of carotid disease, yet luminal stenosis has remained indispensable during clinical decision-making. SNAP imaging has been proposed as a novel IPH imaging technique that provides carotid MRA with no added scan time. Flowing blood shows negative signal on SNAP because of phase-sensitive inversion recovery. MATERIALS AND METHODS: In all, 58 asymptomatic subjects with 16-79% stenosis on ultrasound were scanned at 3T by SNAP with 0.8 mm isotropic resolution and 16 cm longitudinal coverage. Two readers measured luminal stenosis of bilateral carotid arteries (n = 116) on minimum intensity projections of SNAP using the NASCET criteria. In the subset (48 arteries) with contrast-enhanced (CE) MRA available for comparison, luminal stenosis was also measured on maximum intensity projections of CE-MRA. RESULTS: Intraclass correlation coefficients (ICCs) with 95% confidence intervals were 0.94 (0.90-0.96) and 0.93 (0.88-0.96) for intra- and interreader agreement on stenosis measurements, respectively. Corresponding kappas for grading stenosis (0-29%, 30-69%, 70-99%, and 100%) were 0.79 (0.67-0.89) and 0.80 (0.68-0.90). Agreement between SNAP and CE-MRA was high (ICC: 0.95 [0.90-0.98]; kappa: 0.82 [0.71-0.93]). CONCLUSION: As a dedicated IPH-imaging sequence, SNAP also provided carotid stenosis measurement that showed high intra- and interreader consistency and excellent agreement with CE-MRA. Further comparisons with digital subtraction angiography and other noninvasive techniques are warranted. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1045-1052.
PURPOSE: To evaluate in a proof-of-concept study the feasibility of Simultaneous Noncontrast Angiography and intraPlaque hemorrhage (SNAP) imaging as a clinical magnetic resonance angiography (MRA) technique for measuring carotid stenosis. There is a growing interest in detecting intraplaque hemorrhage (IPH) during the clinical management of carotid disease, yet luminal stenosis has remained indispensable during clinical decision-making. SNAP imaging has been proposed as a novel IPH imaging technique that provides carotid MRA with no added scan time. Flowing blood shows negative signal on SNAP because of phase-sensitive inversion recovery. MATERIALS AND METHODS: In all, 58 asymptomatic subjects with 16-79% stenosis on ultrasound were scanned at 3T by SNAP with 0.8 mm isotropic resolution and 16 cm longitudinal coverage. Two readers measured luminal stenosis of bilateral carotid arteries (n = 116) on minimum intensity projections of SNAP using the NASCET criteria. In the subset (48 arteries) with contrast-enhanced (CE) MRA available for comparison, luminal stenosis was also measured on maximum intensity projections of CE-MRA. RESULTS: Intraclass correlation coefficients (ICCs) with 95% confidence intervals were 0.94 (0.90-0.96) and 0.93 (0.88-0.96) for intra- and interreader agreement on stenosis measurements, respectively. Corresponding kappas for grading stenosis (0-29%, 30-69%, 70-99%, and 100%) were 0.79 (0.67-0.89) and 0.80 (0.68-0.90). Agreement between SNAP and CE-MRA was high (ICC: 0.95 [0.90-0.98]; kappa: 0.82 [0.71-0.93]). CONCLUSION: As a dedicated IPH-imaging sequence, SNAP also provided carotid stenosis measurement that showed high intra- and interreader consistency and excellent agreement with CE-MRA. Further comparisons with digital subtraction angiography and other noninvasive techniques are warranted. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1045-1052.
Authors: Norihide Takaya; Chun Yuan; Baocheng Chu; Tobias Saam; Nayak L Polissar; Gail P Jarvik; Carol Isaac; Judith McDonough; Cynthia Natiello; Randy Small; Marina S Ferguson; Thomas S Hatsukami Journal: Circulation Date: 2005-05-23 Impact factor: 29.690
Authors: H J Barnett; D W Taylor; M Eliasziw; A J Fox; G G Ferguson; R B Haynes; R N Rankin; G P Clagett; V C Hachinski; D L Sackett; K E Thorpe; H E Meldrum; J D Spence Journal: N Engl J Med Date: 1998-11-12 Impact factor: 91.245
Authors: Sarah M Debrey; Hua Yu; John K Lynch; Karl-Olof Lövblad; Violet L Wright; Sok-Ja D Janket; Alison E Baird Journal: Stroke Date: 2008-06-12 Impact factor: 7.914
Authors: Jie Sun; Gador Canton; Niranjan Balu; Daniel S Hippe; Dongxiang Xu; Jin Liu; Thomas S Hatsukami; Chun Yuan Journal: Arterioscler Thromb Vasc Biol Date: 2016-02-04 Impact factor: 8.311
Authors: Jin Liu; Jie Sun; Niranjan Balu; Marina S Ferguson; Jinnan Wang; William S Kerwin; Daniel S Hippe; Amy Wang; Thomas S Hatsukami; Chun Yuan Journal: J Magn Reson Imaging Date: 2019-03-12 Impact factor: 4.813