Kareem Allinjawi1, Sharanjeet-Kaur Sharanjeet-Kaur1, Saadah Mohamed Akhir1, Haliza Abdul Mutalib1.
Abstract
Aim: The purpose of this study was to compare the changes in relative peripheral refractive error produced by two different designs of progressive soft contact lenses in myopic schoolchildren.Entities:
Keywords: Progressive contact lens; hyperopic defocus; myopia; peripheral retina
Year: 2016 PMID: 28163898 PMCID: PMC5247792 DOI: 10.12688/f1000research.9971.1
Source DB: PubMed Journal: F1000Res ISSN: 2046-1402
The designs and materials of Progressive contact lenses.
| Multistage PCL | Proclear PCL | |
|---|---|---|
| Brand | 2 weeks multistage | Proclear |
| Material | Group IV - Ioinc high water content | Omfilcon A |
| Modality | 2 weeks | 1 month |
| Power(s) | Type (B) Add +1.50 | Type (D) Add +1.50 |
| Base curve | 8.6 mm | 8.7 mm |
| Diameter | 14.2 mm | 14.4 mm |
|
| 2.5 ɸ mm
| 2.3 ɸ mm
|
| Water content | 58% | 62% |
Mean spherical equivalent ( M ± SD), horizontal astigmatism component ( J 0 ± SD) and oblique astigmatism component ( J 45 ± SD) for 27 eyes at different eccentricities under different conditions: without lens, Multistage PCL (Add +1.50D) and Proclear PCL (Add +1.50).
| Eccentricity |
|
|
| ||||||
|---|---|---|---|---|---|---|---|---|---|
| WL | Multistage
| Proclear
| WL | Multistage
| Proclear
| WL | Multistage
| Proclear
| |
| N35 | -3.32 ±1.59 | -0.41 ±1.25 | 0.02 ±1.35 | 0.11 ±0.84 | -0.04 ±1.15 | 0.14 ±0.86 | 0.18±0.91 | 0.17±0.83 | 0.21±0.9 |
| N30 | -3.6 ±1.49 | -0.73 ±1.01 | -0.41 ±1.19 | 0.02 ±0.93 | -0.08 ±0.78 | 0.15 ±0.6 | -0.15±0.58 | -0.1±0.7 | 0.21±0.83 |
| N25 | -4.09 ± 1.36 | -1.13 ± 0.83 | -0.78 ± 0.97 | 0.06 ±0.7 | 0.23 ±0.55 | 0.01 ±0.62 | -0.18±0.58 | -0.18±0.73 | -0.05±0.59 |
| N20 | -4.31 ±1.09 | -1.3 ±0.59 | -1.14 ±0.76 | 0 ±0.36 | 0 ±0.42 | -0.11 ±0.44 | 0.07±0.51 | 0.21±0.45 | -0.1±0.41 |
| N15 | -4.41 ±1.11 | -1.32 ±0.45 | -1.16 ±0.62 | 0.01 ±0.28 | -0.02 ±0.43 | -0.01 ±0.3 | 0.05±0.37 | -0.09±0.38 | -0.04±0.34 |
| N10 | -4.43 ±0.93 | -1.3 ±0.49 | -1.22 ±0.55 | -0.03 ±0.23 | 0.11 ±0.28 | 0.03 ±0.3 | -0.04±0.25 | -0.04±0.41 | -0.03±0.27 |
| N5 | -4.37 ±0.89 | -1.05 ±0.44 | -1.13 ±0.4 | 0 ±0.27 | 0.04 ±0.26 | 0.07 ±0.24 | -0.01±0.23 | 0.06±0.27 | 0.03±0.29 |
|
| -4.39 ±0.95 | -1.08 ±0.29 | -1.11 ±0.36 | -0.04 ±0.25 | 0 ±0.24 | 0.05 ±0.26 | -0.03±0.23 | -0.01±0.27 | -0.01±0.26 |
| T5 | -4.2 ± 0.98 | -0.89 ±0.57 | -1.19 ±0.5 | 0.02 ±0.26 | 0.07 ±0.22 | -0.03 ±0.34 | -0.06±0.28 | -0.01±0.4 | 0.1±0.37 |
| T10 | -4.52 ±1.04 | -1.01 ± 0.81 | -1.21 ±0.7 | 0.07 ±0.31 | 0.01 ±0.35 | 0 ±0.32 | 0.02±0.32 | -0.05±0.25 | -0.01±0.29 |
| T15 | -4.33 ±1.34 | -0.93 ±0.90 | -1.13 ±0.86 | 0.03 ±0.34 | 0.11 ±0.31 | -0.02 ±0.28 | -0.07±0.27 | 0.06±0.38 | -0.06±0.32 |
| T20 | -4.19 ±1.2 | -0.99 ±1.04 | -0.77 ±0.98 | -0.07 ±0.38 | -0.04 ±0.45 | 0.24 ±0.47 | -0.04±0.36 | -0.2±0.35 | 0.09±0.37 |
| T25 | -3.86 ±1.31 | -0.79 ±1.05 | -0.69 ± 1.02 | -0.05 ±0.34 | 0.01 ±0.36 | 0.07 ±0.33 | -0.01±0.36 | -0.02±0.27 | -0.01±0.3 |
| T30 | -3.63 ±1.35 | -0.72 ±1.05 | -0.5 ±1.13 | -0.07 ±0.54 | 0.07 ±0.45 | 0.04 ±0.44 | 0.11±0.41 | 0.02±0.45 | 0.07±0.53 |
| T35 | -3.34 ±1.32 | -0.57 ±1.14 | -0.3 ±1.11 | 0.13 ±0.5 | -0.25 ±0.58 | 0.19 ±0.4 | -0.01±0.59 | 0.04±0.6 | 0.06±0.39 |
* Values are expressed in diopters (D). N is nasal visual field; T is temporal visual field; C is centre.
Relative peripheral refractive error as mean spherical equivalent values (M±SD), horizontal astigmatism component ( J 0 ± SD) and oblique astigmatism component ( J 45 ± SD) for 27 eyes at different eccentricities under different conditions: without lens, Multistage PCL (Add +1.50D) and Proclear PCL (Add +1.50).
| Eccentricity |
|
|
| ||||||
|---|---|---|---|---|---|---|---|---|---|
| WL ± SD
| Multistage
| Proclear
| WL ± SD
| Multistage
| Proclear
| WL ± SD
| Multistage
| Proclear
| |
| N35 | 1.08±1.24
| 0.67 ± 1.23
| 1.13 ± 1.31
| -0.33 ± 0.84
| -0.51±1.05
| -0.03±0.87
| 0.17±1.02
| 0.18±0.87
| 0.29±0.92
|
| N30 | 0.8±1.1
| 0.35 ± 1.02
| 0.69 ± 1.16
| 0.4 ± 1.03
| -0.05±0.82
| 0.18±0.69
| -0.19±0.61
| -0.16±0.72
| 0.17±0.87
|
| N25 | 0.31±0.86
| -0.05 ± 0.79
| 0.32 ± 0.91
| 0.1 ± 0.7
| 0.19±0.71
| 0.01±0.66
| -0.19±0.7
| -0.12±0.64
| 0.04±0.57
|
| N20 | 0.09±0.57
| -0.22 ± 0.5
| -0.03 ± 0.66
| 0.05 ± 0.51
| -0.07±0.55
| -0.07±0.42
| 0.01±0.42
| 0.18±0.33
| -0.14±0.38
|
| N15 | 0.03 ± 0.43
| -0.24 ± 0.35
| -0.06 ± 0.5
| 0.02 ± 0.29
| -0.05±0.38
| -0.06±0.4
| -0.03±0.3
| -0.14±0.27
| -0.03±0.38
|
| N10 | 0.02 ± 0.35
| -0.22 ± 0.46
| -0.1 ± 0.41
| 0.03 ± 0.32
| 0.02±0.48
| 0.04±0.38
| -0.04±0.23
| -0.01±0.48
| -0.02±0.33
|
| N5 | 0.02 ± 0.19
| 0.03 ± 0.37
| -0.02 ± 0.22
| -0.01 ± 0.37
| -0.05±0.33
| 0.04±0.31
| -0.01±0.26
| 0.02±0.36
| 0.01±0.37
|
| T5 | -0.02 ± 0.31
| 0.19 ± 0.56
| -0.08 ± 0.43
| 0.09 ± 0.28
| 0.01±0.35
| -0.05±0.39
| -0.06±0.37
| -0.01±0.34
| 0.05±0.33
|
| T10 | -0.13 ± 0.50
| 0.07 ± 0.8
| -0.1 ± 0.59
| 0.05 ± 0.32
| -0.03±0.46
| -0.03±0.46
| 0±0.35
| -0.04±0.38
| -0.03±0.39
|
| T15 | 0.06 ± 0.92
| 0.15 ± 0.9
| -0.02 ± 0.79
| 0.06 ± 0.33
| 0.07±0.42
| -0.12±0.4
| -0.08±0.28
| 0.11±0.46
| -0.04±0.37
|
| T20 | 0.2 ± 0.77
| 0.08 ± 1.04
| 0.34 ± 0.94
| -0.02 ± 0.48
| -0.11±0.43
| 0.11±0.6
| -0.07±0.44
| -0.18±0.36
| 0.16±0.38
|
| T25 | 0.54 ± 0.90
| 0.29 ± 1.06
| 0.42 ± 0.95
| -0.01 ± 0.37
| -0.05±0.45
| -0.01±0.53
| -0.02±0.45
| -0.03±0.42
| -0.05±0.36
|
| T30 | 0.76 ± 1.09
| 0.36 ± 1.06
| 0.64 ± 1.05
| 0.09 ± 0.42
| 0.01±0.38
| 0.01±0.58
| 0.1±0.42
| -0.07±0.34
| 0.06±0.62
|
| T35 | 1.06 ± 1.06
| 0.52 ± 1.14
| 0.81 ± 1.1
| -0.01 ± 0.46
| -0.36±0.58
| 0.08±0.36
| -0.03±0.61
| 0.04±0.51
| 0.04±0.46
|
*Values are expressed in diopters (D). N is nasal visual field; T is temporal visual field; C is centre; p represents the value of statistical significance according to Paired t-test or Wilcoxon Signed Ranks Test. Bold indicates statistically significant power difference from central point (95% confid
Figure 1. Baseline, Multistage PCL, and Proclear PCL of relative peripheral refractive error for mean spherical equivalent values ( M) at different eccentricities in the temporal (T) and nasal (N) visual fields.
Figure 2. Baseline, Multistage PCL, and Proclear PCL of relative peripheral refractive error for horizontal astigmatism component values ( J 0) at different eccentricities in the temporal (T) and nasal (N) visual fields.
Figure 3. Baseline, Multistage PCL, and Proclear PCL of relative peripheral refractive error for oblique astigmatism component values ( J 45) at different eccentricities in the temporal (T) and nasal (N) visual fields.