Optimization of propagation-based x-ray phase-contrast tomography for breast cancer imaging.

P Baran1, S Pacile, Y I Nesterets, S C Mayo, C Dullin, D Dreossi, F Arfelli, D Thompson, D Lockie, M McCormack, S T Taba, F Brun, M Pinamonti, C Nickson, C Hall, M Dimmock, F Zanconati, M Cholewa, H Quiney, P C Brennan, G Tromba, T E Gureyev.   

Abstract

The aim of this study was to optimise the experimental protocol and data analysis for in-vivo breast cancer x-ray imaging. Results are presented of the experiment at the SYRMEP beamline of Elettra Synchrotron using the propagation-based phase-contrast mammographic tomography method, which incorporates not only absorption, but also x-ray phase information. In this study the images of breast tissue samples, of a size corresponding to a full human breast, with radiologically acceptable x-ray doses were obtained, and the degree of improvement of the image quality (from the diagnostic point of view) achievable using propagation-based phase-contrast image acquisition protocols with proper incorporation of x-ray phase retrieval into the reconstruction pipeline was investigated. Parameters such as the x-ray energy, sample-to-detector distance and data processing methods were tested, evaluated and optimized with respect to the estimated diagnostic value using a mastectomy sample with a malignant lesion. The results of quantitative evaluation of images were obtained by means of radiological assessment carried out by 13 experienced specialists. A comparative analysis was performed between the x-ray and the histological images of the specimen. The results of the analysis indicate that, within the investigated range of parameters, both the objective image quality characteristics and the subjective radiological scores of propagation-based phase-contrast images of breast tissues monotonically increase with the strength of phase contrast which in turn is directly proportional to the product of the radiation wavelength and the sample-to-detector distance. The outcomes of this study serve to define the practical imaging conditions and the CT reconstruction procedures appropriate for low-dose phase-contrast mammographic imaging of live patients at specially designed synchrotron beamlines.

Entities:  

Mesh:

Year:  2017        PMID: 28140377     DOI: 10.1088/1361-6560/aa5d3d

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction.

Authors:  Luca Brombal; Bruno Golosio; Fulvia Arfelli; Deborah Bonazza; Adriano Contillo; Pasquale Delogu; Sandro Donato; Giovanni Mettivier; Piernicola Oliva; Luigi Rigon; Angelo Taibi; Giuliana Tromba; Fabrizio Zanconati; Renata Longo
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-27

2.  Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging.

Authors:  Kathyayini Sivasubramanian; Vijitha Periyasamy; Manojit Pramanik
Journal:  J Vis Exp       Date:  2017-10-16       Impact factor: 1.355

3.  Comparison of propagation-based CT using synchrotron radiation and conventional cone-beam CT for breast imaging.

Authors:  Seyedamir Tavakoli Taba; Patrycja Baran; Yakov I Nesterets; Serena Pacile; Susanne Wienbeck; Christian Dullin; Konstantin Pavlov; Anton Maksimenko; Darren Lockie; Sheridan C Mayo; Harry M Quiney; Diego Dreossi; Fulvia Arfelli; Giuliana Tromba; Sarah Lewis; Timur E Gureyev; Patrick C Brennan
Journal:  Eur Radiol       Date:  2020-01-23       Impact factor: 5.315

4.  Optimization of the energy for Breast monochromatic absorption X-ray Computed Tomography.

Authors:  Pasquale Delogu; Vittorio Di Trapani; Luca Brombal; Giovanni Mettivier; Angelo Taibi; Piernicola Oliva
Journal:  Sci Rep       Date:  2019-09-11       Impact factor: 4.379

Review 5.  Multiplexed imaging in oncology.

Authors:  Chrysafis Andreou; Ralph Weissleder; Moritz F Kircher
Journal:  Nat Biomed Eng       Date:  2022-05-27       Impact factor: 25.671

6.  Impact of a single distance phase retrieval algorithm on spatial resolution in X-ray inline phase sensitive imaging.

Authors:  Muhammad U Ghani; Bradley Gregory; Farid Omoumi; Bin Zheng; Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Biomed Spectrosc Imaging       Date:  2019-02-22

7.  Detectability comparison of simulated tumors in digital breast tomosynthesis using high-energy X-ray inline phase sensitive and commercial imaging systems.

Authors:  Muhammad U Ghani; Molly D Wong; Farid H Omoumi; Bin Zheng; Laurie L Fajardo; Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Phys Med       Date:  2018-02-23       Impact factor: 2.685

8.  CT dose reduction factors in the thousands using X-ray phase contrast.

Authors:  Marcus J Kitchen; Genevieve A Buckley; Timur E Gureyev; Megan J Wallace; Nico Andres-Thio; Kentaro Uesugi; Naoto Yagi; Stuart B Hooper
Journal:  Sci Rep       Date:  2017-11-21       Impact factor: 4.379

9.  Free propagation phase-contrast breast CT provides higher image quality than cone-beam breast-CT at low radiation doses: a feasibility study on human mastectomies.

Authors:  S Pacilè; C Dullin; P Baran; M Tonutti; C Perske; U Fischer; J Albers; F Arfelli; D Dreossi; K Pavlov; A Maksimenko; S C Mayo; Y I Nesterets; S Tavakoli Taba; S Lewis; P C Brennan; T E Gureyev; G Tromba; S Wienbeck
Journal:  Sci Rep       Date:  2019-09-24       Impact factor: 4.379

10.  Effect of x-ray energy on the radiological image quality in propagation-based phase-contrast computed tomography of the breast.

Authors:  Sarina Wan; Benedicta D Arhatari; Yakov I Nesterets; Sheridan C Mayo; Darren Thompson; Jane Fox; Beena Kumar; Zdenka Prodanovic; Daniel Hausermann; Anton Maksimenko; Christopher Hall; Matthew Dimmock; Konstantin M Pavlov; Darren Lockie; Mary Rickard; Ziba Gadomkar; Alaleh Aminzadeh; Elham Vafa; Andrew Peele; Harry M Quiney; Sarah Lewis; Timur E Gureyev; Patrick C Brennan; Seyedamir Tavakoli Taba
Journal:  J Med Imaging (Bellingham)       Date:  2021-07-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.