Literature DB >> 28130871

Evaluation of wrought Zn-Al alloys (1, 3, and 5 wt % Al) through mechanical and in vivo testing for stent applications.

Patrick K Bowen1, Jan-Marten Seitz1, Roger J Guillory2, Jacob P Braykovich1, Shan Zhao1, Jeremy Goldman2, Jaroslaw W Drelich1.   

Abstract

Special high grade zinc and wrought zinc-aluminum (Zn-Al) alloys containing up to 5.5 wt % Al were processed, characterized, and implanted in rats in search of a new family of alloys with possible applications as bioabsorbable endovascular stents. These materials retained roll-induced texture with an anisotropic distribution of the second-phase Al precipitates following hot-rolling, and changes in lattice parameters were observed with respect to Al content. Mechanical properties for the alloys fell roughly in line with strength (190-240 MPa yield strength; 220-300 MPa ultimate tensile strength) and elongation (15-30%) benchmarks, and favorable elastic ranges (0.19-0.27%) were observed. Intergranular corrosion was observed during residence of Zn-Al alloys in the murine aorta, suggesting a different corrosion mechanism than that of pure zinc. This mode of failure needs to be avoided for stent applications because the intergranular corrosion caused cracking and fragmentation of the implants, although the composition of corrosion products was roughly identical between non- and Al-containing materials. In spite of differences in corrosion mechanisms, the cross-sectional reduction of metals in murine aorta was nearly identical at 30-40% and 40-50% after 4.5 and 6 months, respectively, for pure Zn and Zn-Al alloys. Histopathological analysis and evaluation of arterial tissue compatibility around Zn-Al alloys failed to identify areas of necrosis, though both chronic and acute inflammatory indications were present.
© 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 245-258, 2018. © 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  alloys; bioabsorbable stent; corrosion; histology; mechanical testing; zinc

Mesh:

Substances:

Year:  2017        PMID: 28130871     DOI: 10.1002/jbm.b.33850

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  18 in total

1.  Towards revealing key factors in mechanical instability of bioabsorbable Zn-based alloys for intended vascular stenting.

Authors:  Ehsan Mostaed; Malgorzata Sikora-Jasinska; Morteza Shaker Ardakani; Ali Mostaed; Ian M Reaney; Jeremy Goldman; Jaroslaw W Drelich
Journal:  Acta Biomater       Date:  2020-01-23       Impact factor: 8.947

2.  Analysis of vascular inflammation against bioresorbable Zn-Ag based alloys.

Authors:  Alexander A Oliver; Roger J Guillory; Katie L Flom; Lea M Morath; Timothy M Kolesar; Ehsan Mostaed; Malgorzata Sikora-Jasinska; Jaroslaw W Drelich; Jeremy Goldman
Journal:  ACS Appl Bio Mater       Date:  2020-09-24

3.  Novel Zinc / Tungsten Carbide Nanocomposite as Bioabsorbable Implant.

Authors:  Zeyi Guan; Chase S Linsley; Injoo Hwang; Gongcheng Yao; Benjamin M Wu; Xiaochun Li
Journal:  Mater Lett       Date:  2019-12-28       Impact factor: 3.423

Review 4.  Zinc-based alloys for degradable vascular stent applications.

Authors:  Ehsan Mostaed; Malgorzata Sikora-Jasinska; Jaroslaw W Drelich; Maurizio Vedani
Journal:  Acta Biomater       Date:  2018-03-10       Impact factor: 8.947

5.  Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.

Authors:  Adam J Drelich; Shan Zhao; Roger J Guillory; Jaroslaw W Drelich; Jeremy Goldman
Journal:  Acta Biomater       Date:  2017-05-19       Impact factor: 8.947

6.  Evolution of metallic cardiovascular stent materials: A comparative study among stainless steel, magnesium and zinc.

Authors:  Jiayin Fu; Yingchao Su; Yi-Xian Qin; Yufeng Zheng; Yadong Wang; Donghui Zhu
Journal:  Biomaterials       Date:  2019-11-21       Impact factor: 12.479

Review 7.  Laser Additive Manufacturing of Zinc Targeting for Biomedical Application.

Authors:  Yan Zhou; Jingwen Wang; Youwen Yang; Mingli Yang; Haizhong Zheng; Deqiao Xie; Dongsheng Wang; Lida Shen
Journal:  Int J Bioprint       Date:  2022-01-06

8.  Experimental study on novel biodegradable Zn-Fe-Si alloys.

Authors:  Yuxin Zeng; Zeyi Guan; Chase S Linsley; Shuaihang Pan; Jingke Liu; Benjamin M Wu; Xiaochun Li
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2022-05-06       Impact factor: 3.405

9.  The effects of alloying with Cu and Mn and thermal treatments on the mechanical instability of Zn-0.05Mg alloy.

Authors:  Morteza Shaker Ardakani; Ehsan Mostaed; Malgorzata Sikora-Jasinska; Stephen L Kampe; Jaroslaw W Drelich
Journal:  Mater Sci Eng A Struct Mater       Date:  2019-10-09       Impact factor: 5.234

10.  In vivo performances of pure Zn and Zn-Fe alloy as biodegradable implants.

Authors:  Alon Kafri; Shira Ovadia; Galit Yosafovich-Doitch; Eli Aghion
Journal:  J Mater Sci Mater Med       Date:  2018-06-25       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.