| Literature DB >> 28120559 |
Seung Yul Lee1, Dong Ho Shin2,3, Jung Sun Kim2,3, Byeong Keuk Kim2,3, Young Guk Ko2,3, Donghoon Choi2,3, Yangsoo Jang2,3,4, Myeong Ki Hong2,3,5.
Abstract
PURPOSE: To evaluate the effects of sex and anthropometry on clinical outcomes in patients who underwent percutaneous coronary intervention (PCI).Entities:
Keywords: Coronary artery disease; intravascular ultrasound; sex
Mesh:
Substances:
Year: 2017 PMID: 28120559 PMCID: PMC5290008 DOI: 10.3349/ymj.2017.58.2.296
Source DB: PubMed Journal: Yonsei Med J ISSN: 0513-5796 Impact factor: 2.759
Baseline, Procedural, and IVUS Characteristics by Sex
| Women (n=333) | Men (n=333) | ||
|---|---|---|---|
| Age (yrs) | 67.2±8.0 | 66.4±8.0 | 0.222 |
| Height (cm) | 154.2±5.3 | 166.8±6.1 | <0.001 |
| Weight (kg) | 58.4±8.1 | 68.3±9.1 | <0.001 |
| Body surface area (m2) | 1.6±0.1 | 1.8±0.1 | <0.001 |
| Body mass index (kg/m2) | 24.6±3.3 | 24.5±2.7 | 0.667 |
| Lean body mass (kg) | 40.9±3.4 | 53.5±5.4 | <0.001 |
| Fat mass (kg) | 17.5±5.3 | 14.8±4.1 | <0.001 |
| Hypertension | 235 (70.6) | 227 (68.2) | 0.501 |
| Diabetes mellitus | 126 (37.8) | 123 (36.9) | 0.810 |
| Dyslipidemia | 247 (74.2) | 237 (71.2) | 0.385 |
| Current smoker | 9 (2.7) | 12 (3.6) | 0.506 |
| Clinical diagnosis | 0.689 | ||
| Stable angina | 197 (59.2) | 186 (55.9) | |
| Unstable angina | 110 (33.0) | 119 (35.7) | |
| Acute myocardial infarction | 26 (7.8) | 28 (8.4) | |
| Multi-vessel disease | 201 (60.4) | 209 (62.8) | 0.524 |
| Multi-vessel stent implantation | 88 (26.4) | 80 (24.0) | 0.475 |
| Chronic total occlusion | 37 (11.1) | 40 (12.0) | 0.716 |
| Duration of dual anti-platelet therapy (months) | 12.0 (6.0, 12.0) | 9.6 (6.0, 12.0) | 0.626 |
| Coronary arteries | 0.728 | ||
| Left anterior descending artery | 224 (67.3) | 215 (64.6) | |
| Left circumflex artery | 44 (13.2) | 50 (15.0) | |
| Right coronary artery | 65 (19.5) | 68 (20.4) | |
| Quantitative angiography analysis | |||
| Pre-intervention | |||
| Reference vessel diameter (mm) | 2.8±0.4 | 2.9±0.5 | 0.038 |
| Minimum lumen diameter (mm) | 0.8±0.5 | 0.8±0.5 | 0.109 |
| Diameter stenosis (%) | 70.6±16.1 | 73.6±15.9 | 0.020 |
| Lesion length (mm) | 33.8±11.3 | 34.1±12.4 | 0.705 |
| Post-intervention | |||
| Reference vessel diameter (mm) | 2.9±0.4 | 3.0±0.5 | 0.008 |
| Minimum lumen diameter (mm) | 2.5±0.4 | 2.6±0.4 | <0.001 |
| Diameter stenosis (%) | 12.5±8.4 | 12.0±9.2 | 0.491 |
| Stent type | 0.656 | ||
| Everolimus-eluting stent | 250 (75.1) | 260 (78.1) | |
| Zotarolimus-eluting stent | 63 (18.9) | 55 (16.5) | |
| Biolimus-eluting stent | 20 (6.0) | 18 (5.4) | |
| Stent overlap | 112 (33.6) | 107 (32.1) | 0.680 |
| Stent diameter (mm) | 3.0±0.3 | 3.1±0.4 | <0.001 |
| Stent length (mm) | 39.6±13.9 | 39.5±14.3 | 0.932 |
| Adjunct post-dilation | 235 (70.6) | 225 (67.6) | 0.402 |
| Final balloon size (mm) | 3.0±0.4 | 3.1±0.4 | 0.023 |
| Maximal inflation pressure (atm) | 17.3±3.9 | 16.3±3.8 | 0.009 |
| Post-intervention IVUS analysis | |||
| Proximal reference segment EEM area (mm2) | 15.9±4.4 | 18.2±5.3 | <0.001 |
| Proximal reference segment lumen area (mm2) | 8.4±2.8 | 9.0±3.4 | 0.017 |
| Minimum lumen area (mm2) | 5.3±1.6 | 5.8±1.8 | 0.002 |
| Distal reference segment EEM area (mm2) | 9.0±3.4 | 10.5±4.3 | <0.001 |
| Distal reference segment lumen area (mm2) | 5.8±1.8 | 6.3±2.2 | 0.004 |
IVUS, intravascular ultrasound; EEM, external elastic membrane.
Data are presented as n (%), means±SD, or medians (interquartile ranges).
Adverse Cardiac Events at 12 Months
| Women (n=333) | Men (n=333) | Hazard ratio (95% confidence interval) | ||
|---|---|---|---|---|
| Adverse cardiac events | 8 (2.4) | 8 (2.4) | 1.039 (0.390–2.769) | 0.939 |
| Cardiac death* | 0 (0) | 2 (0.6) | - | 0.499 |
| Target lesion–related myocardial infarction* | 0 (0) | 2 (0.6) | - | 0.499 |
| Ischemia-driven target lesion revascularization | 8 (2.4) | 6 (1.8) | 1.381 (0.479–3.982) | 0.551 |
*Categorical variables were compared with Fisher's exact test (for 2-way comparisons).
Fig. 1Associations among anthropometric measurements and post-intervention minimum lumen area (MLA) as evaluated by intravascular ultrasound. While height, weight, body surface area, and lean body mass were significantly associated with post-intervention MLA, body mass index and fat mass were not. Black dots indicate women and white dots indicate men.
Baseline, Procedural, and IVUS Characteristics According to Height Tertile
| Height | ||||
|---|---|---|---|---|
| Low (n = 213) | Intermediate (n = 220) | High (n = 233) | ||
| Age (yrs) | 68.0±7.9 | 66.8±7.8 | 65.7±8.1 | 0.011 |
| Men | 12 (5.6) | 101 (45.9) | 220 (94.4) | <0.001 |
| Height (cm) | 150.9±3.6 | 159.9±2.6 | 170.0±4.0 | <0.001 |
| Weight (kg) | 57.1±7.8 | 61.9±8.0 | 70.6±8.8 | <0.001 |
| Body surface area (m2) | 1.5±0.1 | 1.7±0.1 | 1.8±0.1 | <0.001 |
| Body mass index (kg/m2) | 25.1±3.3 | 24.2±3.0 | 24.4±2.7 | 0.009 |
| Lean body mass (kg) | 39.8±3.1 | 46.0±4.8 | 55.1±5.2 | <0.001 |
| Fat mass (kg) | 17.3±5.3 | 15.9±5.2 | 15.4±4.2 | <0.001 |
| Hypertension | 156 (73.2) | 150 (68.2) | 156 (67.0) | 0.319 |
| Diabetes mellitus | 84 (39.4) | 83 (37.7) | 82 (35.2) | 0.647 |
| Dyslipidemia | 151 (70.9) | 161 (73.2) | 172 (73.8) | 0.770 |
| Current smoker | 6 (2.8) | 5 (2.3) | 10 (4.3) | 0.443 |
| Acute myocardial infarction | 14 (6.6) | 15 (6.8) | 25 (10.7) | 0.191 |
| Multi-vessel disease | 127 (59.6) | 139 (63.2) | 144 (61.8) | 0.745 |
| Multi-vessel stent implantation | 56 (26.3) | 57 (35.9) | 55 (23.6) | 0.776 |
| Chronic total occlusion | 28 (13.1) | 24 (10.9) | 25 (10.7) | 0.680 |
| Duration of dual anti-platelet therapy (months) | 12.0 (6.0, 12.0) | 12.0 (6.0, 12.0) | 6.0 (6.0, 12.0) | 0.298 |
| Coronary arteries | 0.366 | |||
| Left anterior descending artery | 148 (69.5) | 141 (64.1) | 150 (64.4) | |
| Left circumflex artery | 24 (11.3) | 30 (13.6) | 40 (17.2) | |
| Right coronary artery | 41 (19.2) | 49 (22.3) | 43 (18.4) | |
| Quantitative angiography analysis | ||||
| Pre-intervention | ||||
| Reference vessel diameter (mm) | 2.8±0.4 | 2.8±0.5 | 2.9±0.5 | 0.328 |
| Minimum lumen diameter (mm) | 0.8±0.5 | 0.8±0.5 | 0.8±0.5 | 0.720 |
| Diameter stenosis (%) | 71.5±16.5 | 71.5±15.8 | 73.3±15.8 | 0.402 |
| Lesion length (mm) | 34.7±12.0 | 32.5±11.1 | 34.6±12.5 | 0.096 |
| Post-intervention | ||||
| Reference vessel diameter (mm) | 2.9±0.4 | 3.0±0.5 | 3.0±0.5 | 0.144 |
| Minimum lumen diameter (mm) | 2.5±0.3 | 2.6±0.4 | 2.6±0.4 | 0.005 |
| Diameter stenosis (%) | 12.4±8.9 | 11.4±8.6 | 12.9±8.9 | 0.195 |
| Stent type | 0.519 | |||
| Everolimus-eluting stent | 160 (75.1) | 166 (75.5) | 184 (79.0) | |
| Zotarolimus-eluting stent | 37 (17.4) | 44 (20.0) | 37 (15.9) | |
| Biolimus-eluting stent | 16 (7.5) | 10 (4.5) | 12 (5.2) | |
| Stent overlap | 76 (35.7) | 67 (30.5) | 76 (32.6) | 0.509 |
| Stent diameter (mm) | 3.0±0.3 | 3.0±0.4 | 3.1±0.4 | <0.001 |
| Stent length (mm) | 40.8±14.6 | 38.5±13.8 | 39.4±13.8 | 0.233 |
| Adjunct post-dilation | 142 (66.7) | 161 (73.2) | 157 (67.4) | 0.269 |
| Final balloon size (mm) | 3.1±0.4 | 3.1±0.4 | 3.2±0.5 | 0.110 |
| Maximal inflation pressure (atm) | 17.3±4.0 | 16.6±4.1 | 16.5±3.5 | 0.176 |
| Post-intervention IVUS analysis | ||||
| Proximal reference segment EEM area (mm2) | 16.1±4.4 | 16.6±4.9 | 18.3±5.5 | <0.001 |
| Proximal reference segment lumen area (mm2) | 8.3±2.7 | 8.6±2.9 | 9.2±3.6 | 0.022 |
| Minimum lumen area (mm2) | 5.2±1.5 | 5.6±1.8 | 5.9±1.8 | <0.001 |
| Distal reference segment EEM area (mm2) | 8.7±3.0 | 9.6±4.0 | 10.9±4.4 | <0.001 |
| Distal reference segment lumen area (mm2) | 5.6±1.6 | 6.0±2.0 | 6.4±2.3 | <0.001 |
IVUS, intravascular ultrasound; EEM, external elastic membrane.
Data are presented as n (%), means±SD, or medians (interquartile ranges).
Fig. 2Adjusted event-free survival curve for the composite of cardiac death, target lesion–related myocardial infarction, and ischemia-driven target lesion revascularization, grouped by height tertile. The adjustment included age and sex, and the adjusted hazard ratio (HR) was relative to patients in the high tertile of height. CI, confidence interval.