Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses.

Jung-Sun Kim1, Tae-Soo Kang, Gary S Mintz, Byoung-Eun Park, Dong-Ho Shin, Byeong-Keuk Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong.   

Abstract

OBJECTIVES: This study sought to assess the impact of intravascular ultrasound (IVUS) guidance on clinical outcomes following drug-eluting stent implantation when treating long lesions.
BACKGROUND: The role of IVUS guidance when treating long lesions has been tested during bare-metal stent, but not during drug-eluting stent, implantation.
METHODS: A total of 543 patients treated with stents ≥ 28 mm in length were randomly assigned to IVUS guidance (n = 269) versus angiography guidance (n = 274). The primary endpoint was a composite of major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction, target vessel revascularization, or stent thrombosis at 1 year following intervention.
RESULTS: In the intention-to-treat analysis, total stent length was 32.4 mm in the IVUS-guided arm versus 32.3 mm in angiography-guided arm (p = 0.84). Adjunct post-dilation was more frequently performed in the IVUS-guided arm (54.6% vs. 44.5%, p = 0.03); post-intervention minimal lumen diameters were similar (2.55 vs. 2.55 mm, respectively, p = 0.50); and MACE occurred in 12 (4.5%) patients in IVUS-guided arm and in 20 (7.3%) patients in the angiography-guided arm (p = 0.16). However, among the 269 patients assigned to IVUS guidance, IVUS was not used in 13 patients (4.8%); conversely, in 274 patients assigned to angiography alone, 41 patients (15.0%) were treated with IVUS guidance. Therefore, in a per-protocol analysis according to actual IVUS usage, minimum lumen diameter was larger (2.58 vs. 2.51 mm, p = 0.04), and MACE rates were lower: 4.0% in the IVUS-guided arm versus 8.1% in the angiography-guided arm (p = 0.048).
CONCLUSIONS: A strategy of routine IVUS for drug-eluting stent implantation in long lesions did not improve the 1-year MACE rates. The IVUS use per operator decision was associated with improved results. (A New Strategy Regarding Discontinuation of Dual Antiplatelet; NCT01145079).
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23523455     DOI: 10.1016/j.jcin.2012.11.009

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  28 in total

1.  Real-world use of intravascular ultrasound in Japan: a report from contemporary multicenter PCI registry.

Authors:  Toshiki Kuno; Yohei Numasawa; Mitsuaki Sawano; Takayuki Abe; Ikuko Ueda; Masaki Kodaira; Masahiro Suzuki; Shigetaka Noma; Iwao Nakamura; Koji Negishi; Shiro Ishikawa; Keiichi Fukuda; Shun Kohsaka
Journal:  Heart Vessels       Date:  2019-05-25       Impact factor: 2.037

2.  Optical coherence tomography- vs. intravascular ultrasound-guided percutaneous coronary intervention.

Authors:  Lorenz Räber; Yasushi Ueki
Journal:  J Thorac Dis       Date:  2017-06       Impact factor: 2.895

3.  Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents.

Authors:  Soo-Jin Kang; Gary S Mintz
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

4.  The impact of IVUS guidance in treating complex lesions; are all "complex" lesions the same?

Authors:  Kayode O Kuku; Alexandre H Kajita; Hector M Garcia-Garcia
Journal:  Cardiovasc Diagn Ther       Date:  2017-12

5.  Comparison of clinical outcomes between intravascular ultrasound-guided and angiography-guided drug-eluting stent implantation: A meta-analysis of randomised control trials and systematic review.

Authors:  Yu-Ying Tan; Xia-Xia Man; Ling-Yun Liu; Hui Xu
Journal:  Int Wound J       Date:  2019-01-30       Impact factor: 3.315

6.  Intravascular ultrasound-guided drug-eluting stent implantation is associated with improved clinical outcomes in patients with unstable angina and complex coronary artery true bifurcation lesions.

Authors:  Liang Chen; Tian Xu; Xian-Jun Xue; Jun-Jie Zhang; Fei Ye; Nai-Liang Tian; Shao-Liang Chen
Journal:  Int J Cardiovasc Imaging       Date:  2018-07-06       Impact factor: 2.357

7.  Impact and trends of intravascular imaging in diagnostic coronary angiography and percutaneous coronary intervention in inpatients in the United States.

Authors:  Nathaniel R Smilowitz; Divyanshu Mohananey; Louai Razzouk; Giora Weisz; James N Slater
Journal:  Catheter Cardiovasc Interv       Date:  2018-07-18       Impact factor: 2.692

Review 8.  Practical application of coronary imaging devices in cardiovascular intervention.

Authors:  Yun-Kyeong Cho; Seung-Ho Hur
Journal:  Korean Circ J       Date:  2015-03-24       Impact factor: 3.243

9.  The Effect of Sex and Anthropometry on Clinical Outcomes in Patients Undergoing Percutaneous Coronary Intervention for Complex Coronary Lesions.

Authors:  Seung Yul Lee; Dong Ho Shin; Jung Sun Kim; Byeong Keuk Kim; Young Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong Ki Hong
Journal:  Yonsei Med J       Date:  2017-03       Impact factor: 2.759

Review 10.  Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis.

Authors:  Yao-Jun Zhang; Si Pang; Xiao-Yun Chen; Christos V Bourantas; Dao-Rong Pan; Sheng-Jie Dong; Wen Wu; Xiao-Min Ren; Hao Zhu; Shun-Yi Shi; Javaid Iqbal; Bill D Gogas; Bo Xu; Shao-Liang Chen
Journal:  BMC Cardiovasc Disord       Date:  2015-11-17       Impact factor: 2.298

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.