Literature DB >> 28115797

Osteolysis in total hip arthroplasty after head and inlay revision surgery.

Lorenz Pisecky1, Günter Hipmair1, Bernhard Schauer1, Nikolaus Böhler1.   

Abstract

Wear debris seems to be the most likely reason for osteolysis in THA. The aim was to show the influence of head and acetabular liner revision surgery on osteolytic zones around the femoral component. Can head and inlay revision surgery reduce the size of the osteolytic zones around the femoral component? Which patients could benefit? 47 patients (51 hips), who had undergone THA head and inlay revision surgery between 1999 and 2011, were reviewed. The mean lifetime for the prosthesis was 15.1 years (8-26, standard deviation 4.5) and the mean follow-up for head and inlay was 39.2 months (12-113, standard deviation 30). The heads used in revision surgery were made of metal (26) and ceramics (25). In 36 cases a ultra-high-molecular-weight polyethylene inlay was taken, in 15 cases a regular PE-inlay. We compared the pre-surgical and follow-up anterior-posterior X-rays. The mean size of radiolucent areas before revision surgery was 147 sq.mm (5-389 sq.mm, standard deviation 115). Thirty-nine months (12-113) after surgery, their mean size was 145 sq.mm (7-604 sq.mm, standard deviation 124). Radiolucent zones exceeding 100 sq.mm could be reduced by an average of 28% in 18 out of 29 cases. The results showed an improvement in 29 out of 51 cases and a stop of progress in one case. According to the findings there may be a benefit for patients with big radiolucent areas.

Entities:  

Keywords:  Head; Inlay; Liner; Osteolysis; Radiolucent lines; Revision surgery; Total hip arthroplasty

Year:  2017        PMID: 28115797      PMCID: PMC5226668          DOI: 10.1016/j.jor.2016.12.004

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  10 in total

Review 1.  Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.

Authors:  P C Oparaugo; I C Clarke; H Malchau; P Herberts
Journal:  Acta Orthop Scand       Date:  2001-02

2.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

3.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

4.  Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: a cadaveric study.

Authors:  Tim A Walde; Daniel E Weiland; Serena B Leung; Nobuto Kitamura; Christi J Sychterz; C Anderson Engh; Alexandra M Claus; Hollis G Potter; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2005-08       Impact factor: 4.176

5.  The John Charnley Award. Wear is a function of use, not time.

Authors:  T P Schmalzried; E F Shepherd; F J Dorey; W O Jackson; M dela Rosa; F Fa'vae; H A McKellop; C D McClung; J Martell; J R Moreland; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

6.  Isolation and characterization of debris in membranes around total joint prostheses.

Authors:  K J Margevicius; T W Bauer; J T McMahon; S A Brown; K Merritt
Journal:  J Bone Joint Surg Am       Date:  1994-11       Impact factor: 5.284

7.  The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis.

Authors:  T P Schmalzried; D Guttmann; M Grecula; H C Amstutz
Journal:  J Bone Joint Surg Am       Date:  1994-05       Impact factor: 5.284

Review 8.  Femoral osteolysis following total hip replacement.

Authors:  R Dattani
Journal:  Postgrad Med J       Date:  2007-05       Impact factor: 2.401

9.  Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement.

Authors:  W J Maloney; R L Smith; T P Schmalzried; J Chiba; D Huene; H Rubash
Journal:  J Bone Joint Surg Am       Date:  1995-09       Impact factor: 5.284

10.  The central role of wear debris in periprosthetic osteolysis.

Authors:  P Edward Purdue; Panagiotis Koulouvaris; Bryan J Nestor; Thomas P Sculco
Journal:  HSS J       Date:  2006-09
  10 in total
  3 in total

1.  30-Years of experience with the cementless implanted Alloclassic CSF screw cup total hip arthroplasty system - An ultra-long-term follow-up.

Authors:  Lorenz Pisecky; Günter Hipmair; Bernhard Schauer; Nikolaus Böhler
Journal:  J Orthop       Date:  2019-02-28

2.  30-years of experience with the cementless implanted Alloclassic total hip arthroplasty system-An ultra-long-term follow-up.

Authors:  Lorenz Pisecky; Günter Hipmair; Bernhard Schauer; Nikolaus Böhler
Journal:  J Orthop       Date:  2017-11-06

3.  Straight stem and threaded cup in patients under 60 years of age: 28.8-30.2 years of follow-up.

Authors:  L Pisecky; J Allerstorfer; B Schauer; G Hipmair; R Hochgatterer; N Böhler; T Gotterbarm; M C Klotz
Journal:  J Orthop Surg Res       Date:  2020-11-26       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.