Literature DB >> 28110356

Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology.

Genichiro Takahashi1, Shaban Demirel2, Chris A Johnson3.   

Abstract

PURPOSE: To test the hypothesis that development of glaucomatous visual fields can be predicted several years earlier from prior visual field information.
METHODS: One-hundred and seven eyes with glaucomatous optic neuropathy (n = 47 eyes) or which were suspicious for glaucoma (n = 60) were prospectively enrolled in a longitudinal study. Visual fields were evaluated on an annual basis using standard automated perimetry (SAP), the original version of frequency doubling technology (FDT) perimetry, and a custom version of FDT that used the 24-2 stimulus pattern. All SAP fields were within normal limits at the initial visit. When the SAP glaucoma hemifield test was 'outside normal limits' or the pattern standard deviation probability was worse than the lower 5th percentile or more than two clustered locations at the p < 0.05 level were present on the pattern deviation probability plot, an eye was defined as being abnormal. We used a classification tree analysis to predict which eyes would convert, using only baseline test results.
RESULTS: Classification trees that were constructed using only baseline data had excellent specificity (near 100%) but worse sensitivity (25-50%) for predicting which eyes would convert during follow-up.
CONCLUSIONS: Predictive information is present in visual field results, even when they are still within normal limits.

Entities:  

Keywords:  Frequency doubling; Glaucoma; Progression; Visual fields

Mesh:

Year:  2017        PMID: 28110356     DOI: 10.1007/s00417-016-3573-x

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  32 in total

1.  Perimetric defects and ganglion cell damage: interpreting linear relations using a two-stage neural model.

Authors:  William H Swanson; Joost Felius; Fei Pan
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-02       Impact factor: 4.799

2.  Responses of primate retinal ganglion cells to perimetric stimuli.

Authors:  William H Swanson; Hao Sun; Barry B Lee; Dingcai Cao
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-09       Impact factor: 4.799

3.  Progressive color visual field loss in glaucoma.

Authors:  P A Sample; R N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-05       Impact factor: 4.799

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Frequency doubling technology perimetry using a 24--2 stimulus presentation pattern.

Authors:  C A Johnson; G A Cioffi; E M Van Buskirk
Journal:  Optom Vis Sci       Date:  1999-08       Impact factor: 1.973

6.  Incidence and prevalence of short wavelength automated perimetry deficits in ocular hypertensive patients.

Authors:  S Demirel; C A Johnson
Journal:  Am J Ophthalmol       Date:  2001-06       Impact factor: 5.258

7.  Short-wavelength color visual fields in glaucoma suspects at risk.

Authors:  P A Sample; J D Taylor; G A Martinez; M Lusky; R N Weinreb
Journal:  Am J Ophthalmol       Date:  1993-02-15       Impact factor: 5.258

8.  The ability of short-wavelength automated perimetry to predict conversion to glaucoma.

Authors:  Josine van der Schoot; Nicolaas J Reus; Thomas P Colen; Hans G Lemij
Journal:  Ophthalmology       Date:  2009-11-06       Impact factor: 12.079

9.  Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial.

Authors:  Anders Heijl; M Cristina Leske; Bo Bengtsson; Leslie Hyman; Boel Bengtsson; Mohamed Hussein
Journal:  Arch Ophthalmol       Date:  2002-10

10.  Comparison of SWAP and SAP on the point of glaucoma conversion.

Authors:  Ioannis Havvas; Dimitris Papaconstantinou; Marilita M Moschos; Panagiotis G Theodossiadis; Vasilios Andreanos; Pantelis Ekatomatis; Ioannis Vergados; Dimitrios Andreanos
Journal:  Clin Ophthalmol       Date:  2013-09-19
View more
  2 in total

Review 1.  Functional assessment of glaucoma: Uncovering progression.

Authors:  Rongrong Hu; Lyne Racette; Kelly S Chen; Chris A Johnson
Journal:  Surv Ophthalmol       Date:  2020-04-26       Impact factor: 6.048

2.  THE ROLE OF FREQUENCY DOUBLING TECHNOLOGY PERIMETRY IN EARLY DETECTION OF DIABETIC RETINOPATHY.

Authors:  Mario Bradvica; Dubravka Biuk; Ivanka Štenc Bradvica; Maja Vinković; Branimir Cerovski; Ivona Barać
Journal:  Acta Clin Croat       Date:  2020-03       Impact factor: 0.932

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.