Monoenergetic reconstructions for imaging of coronary artery stents using spectral detector CT: In-vitro experience and comparison to conventional images.

Tilman Hickethier1, Bettina Baeßler2, Jan Robert Kroeger2, Jonas Doerner2, Gregor Pahn3, David Maintz2, Guido Michels4, Alexander C Bunck2.   

Abstract

PURPOSE: Accurate assessment of coronary stents using non-invasive CT imaging remains challenging despite new stent materials and improvements in CT technology. Virtual monoenergetic (monoE) images reconstructed from dual energy CT acquisitions potentially decrease artifacts caused by coronary stents. A novel spectral detector technology provides monoE and conventional images simultaneously for all conducted scans. The purpose of our study was to systematically investigate the influence of different monoE reconstructions on the visualization of coronary stent lumen in comparison to conventional images. METHOD AND MATERIALS: Ten different coronary stents (diameter 3.0 mm) embedded in plastic tubes filled with contrast agent (500 HU) were scanned with a 128-row spectral detector CT (IQon, Philips, 120 kV, 125 mAs). Images were reconstructed (0.67 mm slice thickness, 0.35 mm increment) with a stent-specific conventional reconstruction kernel and 6 different monoE settings (60, 70, 80, 90, 100, 150 keV). Image quality for each stent and reconstruction was quantified using established parameters: image noise (standard deviation (SD) within a standardized ROI), in-stent attenuation difference (mean attenuation difference between stented and non-stented lumen) and visible lumen diameter (mean visible diameter of the stented tube).
RESULTS: Image noise was significantly lower in all monoE data dets compared to conventional images (conventional: 13.41, 60 keV: 11.62, 70 keV: 11.67, 80 keV: 11.69, 90 keV: 11.71, 100 keV: 11.75, 150 keV: 11.80 HU SD; p < 0.01). The in-stent attenuation difference was significantly smaller in monoE data with higher keV levels than in conventional images (conventional: 148.18, 60 keV: 154.13 p = 0.036, 70 keV: 143.43 p = 0.109, 80 keV: 137.25 p = 0.052, 90 keV: 133.02 p = 0.043, 100 keV: 130.12 p = 0.039, 150 keV: 123.99 HU p = 0.035). The visible lumen diameter was significantly greater in monoE data with higher keV levels than in conventional images (conventional: 0.65, 60 keV: 0.68 p = 0.542, 70 keV: 0.71 p = 0.053, 80 keV: 0.74 p < 0.01, 90 keV: 0.77 p < 0.01, 100 keV: 0.82 p < 0.01, 150 keV: 0.87 mm p < 0.01).
CONCLUSION: In comparison to conventional CT images, well-established parameters for objective assessment of CT image quality for coronary stents are significantly improved by utilization of monoE reconstructions with adequate keV levels derived from data acquired on a novel spectral detector CT platform.
Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Computed tomography; Coronary artery; DECT; Dual energy; Dual layer; SDCT; Spectral; Spectral detector; Stent

Mesh:

Year:  2017        PMID: 28096049     DOI: 10.1016/j.jcct.2016.12.005

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  19 in total

1.  Initial exploration of coronary stent image subtraction using dual-layer spectral CT.

Authors:  Le Qin; ShengJia Gu; ChiHua Chen; Huan Zhang; ZhenBin Zhu; XingBiao Chen; Qun Han; FuHua Yan; WenJie Yang
Journal:  Eur Radiol       Date:  2019-01-21       Impact factor: 5.315

Review 2.  Training and Service Provision in Cardiovascular CT: International Challenges and Solutions.

Authors:  E D Nicol; J Shambrook; E Shaw; J Leipsic; L Shaw
Journal:  Curr Cardiol Rep       Date:  2017-10-18       Impact factor: 2.931

3.  Influence of heart rate on coronary calcium scores: a multi-manufacturer phantom study.

Authors:  N R van der Werf; M J Willemink; T P Willems; R Vliegenthart; M J W Greuter; T Leiner
Journal:  Int J Cardiovasc Imaging       Date:  2017-12-28       Impact factor: 2.357

4.  Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Yuji Iyama; Narumi Taguchi; Tomohiro Namimoto; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Masataka Nakagawa; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2017-10-23       Impact factor: 5.315

Review 5.  Extra-abdominal dual-energy CT applications: a comprehensive overview.

Authors:  Giuseppe Cicero; Giorgio Ascenti; Moritz H Albrecht; Alfredo Blandino; Marco Cavallaro; Tommaso D'Angelo; Maria Ludovica Carerj; Thomas J Vogl; Silvio Mazziotti
Journal:  Radiol Med       Date:  2020-01-10       Impact factor: 3.469

6.  Myocardial Late Iodine Enhancement and Extracellular Volume Quantification with Dual-Layer Spectral Detector Dual-Energy Cardiac CT.

Authors:  Seitaro Oda; Takafumi Emoto; Takeshi Nakaura; Masafumi Kidoh; Daisuke Utsunomiya; Yoshinori Funama; Yasunori Nagayama; Seiji Takashio; Mitsuharu Ueda; Taro Yamashita; Kenichi Tsujita; Yukio Ando; Yasuyuki Yamashita
Journal:  Radiol Cardiothorac Imaging       Date:  2019-04-25

7.  Evaluation of soft-plaque stenoses in coronary artery stents using conventional and monoenergetic images: first in-vitro experience and comparison of two different dual-energy techniques.

Authors:  Tilman Hickethier; Justus Wenning; Grischa Bratke; David Maintz; Guido Michels; Alexander C Bunck
Journal:  Quant Imaging Med Surg       Date:  2020-03

8.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03

9.  Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT.

Authors:  Haiyan Ren; Yanhua Zhen; Zheng Gong; Chuanzhuo Wang; Zhihui Chang; Jiahe Zheng
Journal:  Quant Imaging Med Surg       Date:  2021-05

10.  Split-filter dual-energy CT pulmonary angiography for the diagnosis of acute pulmonary embolism: a study on image quality and radiation dose.

Authors:  Bernhard Petritsch; Pauline Pannenbecker; Andreas M Weng; Jan-Peter Grunz; Simon Veldhoen; Thorsten A Bley; Aleksander Kosmala
Journal:  Quant Imaging Med Surg       Date:  2021-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.