Literature DB >> 28067707

Dural Puncture Epidural Technique Improves Labor Analgesia Quality With Fewer Side Effects Compared With Epidural and Combined Spinal Epidural Techniques: A Randomized Clinical Trial.

Anthony Chau1, Carolina Bibbo, Chuan-Chin Huang, Kelly G Elterman, Eric C Cappiello, Julian N Robinson, Lawrence C Tsen.   

Abstract

BACKGROUND: The dural puncture epidural (DPE) technique is a modification of the combined spinal epidural (CSE) technique, where a dural perforation is created from a spinal needle but intrathecal medication administration is withheld. The DPE technique has been shown to improve caudal spread of analgesia compared with epidural (EPL) technique without the side effects observed with the CSE technique. We hypothesized that the onset of labor analgesia would follow this order: CSE > DPE > EPL techniques.
METHODS: A total of 120 parturients in early labor were randomly assigned to EPL, DPE, or CSE groups. Initial dosing for EPL and DPE consisted of epidural 20 mL of 0.125% bupivacaine plus fentanyl 2 μg/mL over 5 minutes, and for CSE, intrathecal 0.25% bupivacaine 1.7 mg and fentanyl 17 μg. Upon block completion, a blinded coinvestigator assessed the outcomes. Two blinded obstetricians retrospectively interpreted uterine contractions and fetal heart rate tracings 1 hour before and after the neuraxial technique. The primary outcome was time to numeric pain rating scale (NPRS) ≤ 1 analyzed by using Kaplan-Meier curves and Cox proportional hazard model. Secondary outcomes included block quality, maternal adverse effects, uterine contraction patterns, and fetal outcomes analyzed by using the χ test with Yates continuity correction.
RESULTS: There was no significant difference in the time to NPRS ≤ 1 between DPE and EPL (hazard ratio 1.4; 95% confidence interval [CI] 0.83-2.4, P = .21). DPE achieved NPRS ≤ 1 significantly slower than CSE (hazard ratio 0.36; 95% CI 0.22-0.59, P = .0001). The median times (interquartile range) to NPRS ≤ 1 were 2 (0.5-6) minutes for CSE, 11 (4-120) minutes for DPE, and 18 (10-120) minutes for EPL. Compared with EPL, DPE had significantly greater incidence of bilateral S2 blockade at 10 minutes (risk ratio [RR] 2.13; 95% CI 1.39-3.28; P < .001), 20 minutes (RR 1.60; 95% CI 1.26-2.03; P < .001), and 30 minutes (RR 1.18; 95% CI 1.01-1.30; P < .034), a lower incidence of asymmetric block after 30 minutes (RR 0.19; 95% CI 0.07-0.51; P < .001) and physician top-up intervention (RR 0.45; 95% CI 0.23-0.86; P = .011). Compared with CSE, DPE had a significantly lower incidence of pruritus (RR 0.15; 95% CI 0.06-0.38; P < .001), hypotension (RR 0.38; 95% CI 0.15-0.98; P = .032), combined uterine tachysystole and hypertonus (RR 0.22; 95% CI 0.08-0.60; P < .001), and physician top-up intervention (RR 0.45; 95% CI 0.23-0.86; p = .011).
CONCLUSIONS: Analgesia onset was most rapid with CSE with no difference between DPE and EPL techniques. The DPE technique has improved block quality over the EPL technique with fewer maternal and fetal side effects than the CSE technique for parturients requesting early labor analgesia.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28067707     DOI: 10.1213/ANE.0000000000001798

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  18 in total

Review 1.  Neuraxial analgesia for labour.

Authors:  B Shatil; R Smiley
Journal:  BJA Educ       Date:  2020-01-27

2.  Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial.

Authors:  Sylvia H Wilson; Bethany J Wolf; Kayla Bingham; Quiana S Scotland; John M Fox; Erick M Woltz; Latha Hebbar
Journal:  Anesth Analg       Date:  2018-02       Impact factor: 5.108

Review 3.  A Review of the Impact of Obstetric Anesthesia on Maternal and Neonatal Outcomes.

Authors:  Grace Lim; Francesca L Facco; Naveen Nathan; Jonathan H Waters; Cynthia A Wong; Holger K Eltzschig
Journal:  Anesthesiology       Date:  2018-07       Impact factor: 7.892

Review 4.  Spinal dura mater: biophysical characteristics relevant to medical device development.

Authors:  Sean J Nagel; Chandan G Reddy; Leonardo A Frizon; Matthieu K Chardon; Marshall Holland; Andre G Machado; George T Gillies; Matthew A Howard; Saul Wilson
Journal:  J Med Eng Technol       Date:  2018-03-23

5.  Dural puncture epidural for caesarean delivery in a parturient with multiple sclerosis.

Authors:  M Sharapi; J P R Loughrey
Journal:  Anaesth Rep       Date:  2022-06-02

6.  [Identification of the epidural space using pressure waveform analysis (CompuFlo® technology): a case series].

Authors:  A Helf; T Schlesinger; N Roewer; P Kranke
Journal:  Anaesthesist       Date:  2019-09-20       Impact factor: 1.041

Review 7.  How neuraxial labor analgesia differs by approach: dural puncture epidural as a novel option.

Authors:  Berrin Gunaydin; Selin Erel
Journal:  J Anesth       Date:  2018-10-06       Impact factor: 2.078

Review 8.  Anaesthesia for the parturient with obesity.

Authors:  S D Patel; A S Habib
Journal:  BJA Educ       Date:  2021-02-17

Review 9.  Modern Neuraxial Anesthesia for Labor and Delivery.

Authors:  Marie-Louise Meng; Richard Smiley
Journal:  F1000Res       Date:  2017-07-25

Review 10.  Obstetric Anesthesia and Heart Disease: Practical Clinical Considerations.

Authors:  Marie-Louise Meng; Katherine W Arendt
Journal:  Anesthesiology       Date:  2021-07-01       Impact factor: 8.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.