Literature DB >> 30293143

How neuraxial labor analgesia differs by approach: dural puncture epidural as a novel option.

Berrin Gunaydin1, Selin Erel2.   

Abstract

BACKGROUND AND AIM: Neuraxial analgesia techniques are not limited to just standard epidural and CSE blocks. A novel approach called dural puncture epidural (DPE) which is a modification of CSE in terms of practice has gained popularity after its description and use in the obstetric population.  The aim of this review is to address the practice of DPE technique as a novel option by reviewing its benefits as well as side and/or adverse effects and to understand how neuraxial labor analgesia differs by approach based on the information available in the current literature DISCUSSION: Despite controversies and concerns, more rapid onset of analgesia, early bilateral sacral analgesia, lower incidence of asymmetric block and fewer maternal and fetal side effects are provided with DPE when compared to epidural.
CONCLUSION: DPE offers a favorable risk-benefit ratio for management of neuraxial analgesia as a novel option.

Entities:  

Keywords:  Combined spinal epidural; Dural puncture epidural; Epidural; Labor pain; Neuraxial analgesia

Mesh:

Year:  2018        PMID: 30293143     DOI: 10.1007/s00540-018-2564-y

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  9 in total

1.  Observations on deliberate dural puncture with a Tuohy needle: pressure measurements.

Authors:  R J Telford; T E Hollway
Journal:  Anaesthesia       Date:  1991-09       Impact factor: 6.955

2.  Dural Puncture Epidural Technique Improves Labor Analgesia Quality With Fewer Side Effects Compared With Epidural and Combined Spinal Epidural Techniques: A Randomized Clinical Trial.

Authors:  Anthony Chau; Carolina Bibbo; Chuan-Chin Huang; Kelly G Elterman; Eric C Cappiello; Julian N Robinson; Lawrence C Tsen
Journal:  Anesth Analg       Date:  2017-02       Impact factor: 5.108

3.  Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial.

Authors:  Sylvia H Wilson; Bethany J Wolf; Kayla Bingham; Quiana S Scotland; John M Fox; Erick M Woltz; Latha Hebbar
Journal:  Anesth Analg       Date:  2018-02       Impact factor: 5.108

4.  Subarachnoid spread of epidural local anaesthetic following dural puncture.

Authors:  A Leach; G B Smith
Journal:  Anaesthesia       Date:  1988-08       Impact factor: 6.955

5.  Effect of needle puncture on morphine and lidocaine flux through the spinal meninges of the monkey in vitro. Implications for combined spinal-epidural anesthesia.

Authors:  C M Bernards; D J Kopacz; M Z Michel
Journal:  Anesthesiology       Date:  1994-04       Impact factor: 7.892

6.  Dural puncture with a 27-gauge Whitacre needle as part of a combined spinal-epidural technique does not improve labor epidural catheter function.

Authors:  John A Thomas; Peter H Pan; Lynne C Harris; Medge D Owen; Robert D'Angelo
Journal:  Anesthesiology       Date:  2005-11       Impact factor: 7.892

7.  A randomized trial of dural puncture epidural technique compared with the standard epidural technique for labor analgesia.

Authors:  Eric Cappiello; Nollag O'Rourke; Scott Segal; Lawrence C Tsen
Journal:  Anesth Analg       Date:  2008-11       Impact factor: 5.108

8.  Dural puncture epidural analgesia is not superior to continuous labor epidural analgesia.

Authors:  Deepak Gupta; Arvind Srirajakalidindi; Vitaly Soskin
Journal:  Middle East J Anaesthesiol       Date:  2013-10

9.  Dural puncture with a 26-gauge spinal needle affects spread of epidural anesthesia.

Authors:  N Suzuki; M Koganemaru; S Onizuka; M Takasaki
Journal:  Anesth Analg       Date:  1996-05       Impact factor: 5.108

  9 in total
  1 in total

1.  Dural puncture epidural technique provides better anesthesia quality in repeat cesarean delivery than epidural technique: Randomized controlled study.

Authors:  Sheng-You Wang; Yan He; Hai-Juan Zhu; Bo Han
Journal:  World J Clin Cases       Date:  2022-07-16       Impact factor: 1.534

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.