Abstract

Understanding the relevant biophysical properties of the spinal dura mater is essential to the design of medical devices that will directly interact with this membrane or influence the contents of the intradural space. We searched the literature and reviewed the pertinent characteristics for the design, construction, testing, and imaging of novel devices intended to perforate, integrate, adhere or reside within or outside of the spinal dura mater. The spinal dura mater is a thin tubular membrane composed of collagen and elastin fibres that varies in circumference along its length. Its mechanical properties have been well-described, with the longitudinal tensile strength exceeding the transverse strength. Data on the bioelectric, biomagnetic, optical and thermal characteristics of the spinal dura are limited and sometimes taken to be similar to those of water. While various modalities are available to visualise the spinal dura, magnetic resonance remains the best modality to segment its structure. The reaction of the spinal dura to imposition of a foreign body or other manipulations of it may compromise its biomechanical and immune-protective benefits. Therefore, dural sealants and replacements are of particular clinical, research and commercial interest. In conclusion, existing devices that are in clinical use for spinal cord stimulation, intrathecal access or intradural implantation largely adhere to traditional designs and their attendant limitations. However, if future devices are built with an understanding of the dura's properties incorporated more fully into the designs, there is potential for improved performance.

Entities:  

Keywords:  Dura mater; biophysical characteristics; electric stimulation; prostheses and implants; spine surgery

Mesh:

Year:  2018        PMID: 29569970      PMCID: PMC7053539          DOI: 10.1080/03091902.2018.1435745

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  58 in total

Review 1.  Needle-tissue interaction forces--a survey of experimental data.

Authors:  Dennis J van Gerwen; Jenny Dankelman; John J van den Dobbelsteen
Journal:  Med Eng Phys       Date:  2012-05-22       Impact factor: 2.242

2.  Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.

Authors:  Kiyoshi Ito; Tatsuro Aoyama; Tetsuyoshi Horiuchi; Kazuhiro Hongo
Journal:  J Neurosurg Spine       Date:  2015-08-28

3.  Maternalizing the meninges: a pregnant Arabic legacy.

Authors:  Manu Kothari; Atul Goel
Journal:  Neurol India       Date:  2006-12       Impact factor: 2.117

4.  The morphology and clinical significance of the dorsal meningovertebra ligaments in the lumbosacral epidural space.

Authors:  Benchao Shi; Xiangming Li; Hongliang Li; Zihai Ding
Journal:  Spine (Phila Pa 1976)       Date:  2012-08-15       Impact factor: 3.468

Review 5.  The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds.

Authors:  J F Schenck
Journal:  Med Phys       Date:  1996-06       Impact factor: 4.071

6.  Biomechanics of lumbosacral dural sac. A study of flexion-extension myelography.

Authors:  L Penning; J T Wilmink
Journal:  Spine (Phila Pa 1976)       Date:  1981 Jul-Aug       Impact factor: 3.468

7.  Analysis of dural sac thickness in human spine-cadaver study with confocal infrared laser microscope.

Authors:  Jae-Young Hong; Seung-Woo Suh; Si-Young Park; Hitesh N Modi; Im J Rhyu; Soonwook Kwon; Hyunung Yu; Joonsung Byun
Journal:  Spine J       Date:  2011-12-15       Impact factor: 4.166

8.  Epidural blood patch in post dural puncture headache: a randomised, observer-blind, controlled clinical trial.

Authors:  F van Kooten; R Oedit; S L M Bakker; D W J Dippel
Journal:  J Neurol Neurosurg Psychiatry       Date:  2007-07-17       Impact factor: 10.154

9.  Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache: A meta-analysis.

Authors:  Hong Xu; Yang Liu; WenYe Song; ShunLi Kan; FeiFei Liu; Di Zhang; GuangZhi Ning; ShiQing Feng
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

Review 10.  Postsurgical pathologies associated with intradural electrical stimulation in the central nervous system: design implications for a new clinical device.

Authors:  Katherine N Gibson-Corley; Oliver Flouty; Hiroyuki Oya; George T Gillies; Matthew A Howard
Journal:  Biomed Res Int       Date:  2014-04-01       Impact factor: 3.411

View more
  4 in total

Review 1.  Developmental biology of the meninges.

Authors:  Krishnakali Dasgupta; Juhee Jeong
Journal:  Genesis       Date:  2019-03-13       Impact factor: 2.487

2.  Histologic Comparison of the Dura Mater among Species.

Authors:  Ahmet Kinaci; Wilhelmina Bergmann; Ronald Law Bleys; Albert van der Zwan; Tristan Pc van Doormaal
Journal:  Comp Med       Date:  2020-02-03       Impact factor: 0.982

3.  A hydrogel spinal dural patch with potential anti-inflammatory, pain relieving and antibacterial effects.

Authors:  Jiahao Li; Jingjing Tian; Chunxu Li; Longyun Chen; Yu Zhao
Journal:  Bioact Mater       Date:  2022-02-01

4.  Case Report: Dural Dissection With Ventral Spinal Fluid-Filled Collection in Superficial Siderosis: Insights Into the Pathology From Anterior-Approached Surgical Cases.

Authors:  Toshitaka Yoshii; Takashi Hirai; Satoru Egawa; Motonori Hashimoto; Yu Matsukura; Hiroyuki Inose; Nobuo Sanjo; Takanori Yokota; Atsushi Okawa
Journal:  Front Neurol       Date:  2022-07-13       Impact factor: 4.086

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.